Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Esacure KIP 100 F
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- YXT0-T0FA-C00P-EQ9T
Identified Uses
Photoinitiator.
Uses advised against
No information available
Manufacturers & Suppliers
IGM Resins B.V.
Gompenstraat 49, 5145 RM Waalwijk, The Netherlands
+31 (0) 416 316 657
Emergency Contacts
Emergency Contact
+44 20 35147487
Emergency Contact
0 800 680 0425
Europe
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| A mixture mainly based on: 2,3-dihydro-6-(2-hydroxy-2-methyl-1-oxopropyl)-1,1,3-trimethyl-3-[4-(2-hydroxy-2-methyl-1-oxopropyl)phenyl]-1 H-indene; 2,3-dihydro-5-(2-hydroxy-2-methyl-1-oxopropyl)-1,1,3-trimethyl-3-[4-(2-hydroxy-2-methyl-1-oxopropyl)phenyl]-1 H-indene EC: 402-990-3 | 163702-01-0 | 50 - 70% | Yes |
| 2-hydroxy-2-methylpropiophenone EC: 231-272-0 | 7473-98-5 | 25 - 40% | Yes |
| Benzene | 71-43-2 | 0.0001 - 0.001% | Yes |
Acute Toxicity Estimate If LD50/LC50 data is not available or does not correspond to the classification category, then the appropriate conversion value from CLP Annex I, Table 3.1.2, is used to calculate the acute toxicity estimate (ATEmix) for classifying a mixture based on its components. This product does not contain candidate substances of very high concern at a concentration >=0.1% (Regulation (EC) No. 1907/2006 (REACH), Article 59)
Notes
Full text of H- and EUH-phrases: see section 16
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention immediately if symptoms occur. Treatment should be symptomatic and supportive. If breathing has stopped, give artificial respiration. Get medical attention immediately.
Wash skin with soap and water. In the case of skin irritation or allergic reactions see a doctor.
Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Consult a doctor.
Rinse mouth.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Alcohol resistant foam. Carbon dioxide (CO2). Dry chemical.
Do not scatter spilled material with high pressure water streams.
No information available.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required. Evacuate personnel to safe areas.
See Section 12 for additional Ecological Information.
Take up mechanically, placing in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product. Remove contaminated clothing and shoes. Ensure adequate ventilation.
Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F. Store locked up.
Do not eat, drink or smoke when using this product. Wash hands before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Apply technical measures to comply with the occupational exposure limits. Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Use spark-proof tools and explosion-proof equipment.
Wear suitable gloves. Nitrile rubber: 0.4 mm thickness, 60 minutes breakthrough time. Butyl rubber: 0.4 mm thickness, 60 minutes breakthrough time.
Wear safety glasses with side shields (or goggles).
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.
Wear suitable protective clothing.
Do not allow into any sewer, on the ground or into any body of water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No information available.
None under normal processing. Polymerisation can occur.
Extremes of temperature and direct sunlight.
None known based on information supplied.
None known based on information supplied.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated
- Shipping Name
- Not regulated
- Transport Class
- Not regulated
- Packing Group
- Not regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Esacure KIP 100 F?
The signal word is danger.
What is the physical form of Esacure KIP 100 F?
Esacure KIP 100 F is a liquid appearing as viscous with clear color. It has no information available. odor.
What is the solubility of Esacure KIP 100 F?
No data available
What is Esacure KIP 100 F used for?
Photoinitiator.
What are the hazard statements for Esacure KIP 100 F?
This substance has 3 hazard statements:
- H361f: Suspected of damaging fertility
- H372: Causes damage to organs through prolonged or repeated exposure
- H412: Harmful to aquatic life with long lasting effects
What is the melting point of Esacure KIP 100 F?