Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- R10776A
- Product Code
- 72009
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Additive for car engine lubricating oil
Uses advised against
This material should not be used for any other purpose than that recommended without expert advice.
Manufacturers & Suppliers
INFINEUM NETHERLANDS B.V.
manufacturer
Herikerbergweg 238 Luna Arena, 1101 CM Amsterdam, The Netherlands
+44 1235 549501
http://www.infineum.com
Emergency Contacts
Emergency Contact
+33-4.4274.4690
Emergency Contact
+49-221-7499 3355
Emergency Contact
+39 019-2150 221
Emergency Contact
+44 1235 549777
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
All concentrations are weight percent units for liquids or volume percent units for gaseous products.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Zinc bis[O-(6-methylheptyl)] bis[O-(sec-butyl)] bis(dithiophosphate) EC: 298-577-9 | --- | 3 - 6.25% | Yes |
| Distillates (petroleum), solvent-dewaxed light paraffinic EC: 265-159-2 | --- | 1 - 10% | Yes |
| Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 | --- | 1 - 10% | Yes |
| Phenol, 2 or 4-C14-18 (even numbered) sec-alkyl derivs. | --- | 1 - 10% | Yes |
| distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | --- | 1 - 10% | Yes |
| Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 | --- | 1 - 10% | Yes |
For the full text of the H-Statements mentioned in this Section, see Section 16.
Notes
Other ingredients are either not hazardous or are below the regulatory disclosure limit..
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician. If breathing has stopped, assist ventilation with a mechanical device. Do not use mouth-to-mouth resuscitation if exposure to hydrogen sulphide is suspected.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.
Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.
Immediate Medical Attention
If symptoms persist, call a physician.
Medical Treatment
Show this material safety data sheet to the doctor in attendance. The first aid procedure should be established in consultation with the doctor responsible for industrial medicine. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames
High volume water jet
Not classified as flammable or combustible, but will combust if ignited.
Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. Fire-fighters should exercise extreme caution in enclosed spaces due to the possible presence of toxic decomposition and combustion products.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus. Exposure to decomposition products may be a hazard to health. Self-contained full-face overpressure breathing apparatus should be used in enclosed spaces. Use standard body protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with spilled material. Do not touch or walk through spilled material.
Wipe up with absorbent material (e.g. cloth, fleece).
Dyke far ahead of liquid spill for later recovery and disposal.
Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses.
Recover by pumping or with suitable absorbent. Wipe up with absorbent material (e.g. cloth, fleece).
Materials: suitable absorbent, cloth, fleece
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Smoking, eating and drinking should be prohibited in the application area. Do not reheat above the maximum loading temperature. Extreme caution must be used in tank gauging or similar operations as overheating could lead to accumulation of lethal concentrations of hydrogen sulphide in the head-space of containers. If decomposition is suspected, or if the product has been overheated, do not open the container, discontinue heating and secure the unit.
Keep container tightly closed in a dry and well-ventilated place. No decomposition if stored and applied as directed. Storage temperature : <= 60 °C (140 °F)
Smoking, eating and drinking should be prohibited in the application area.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation. If decomposition is suspected, or if the product has been overheated, do not open the container, discontinue heating and secure the unit. Initiate emergency procedures, taking all necessary precautions to avoid exposure to noxious or flammable gases (e.g. hydrogen sulphide), such as evacuation of contaminated areas, and use of suitable respiratory protection.
Polyvinyl alcohol or nitrile- butyl-rubber gloves. Before removing gloves clean them with soap and water. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
The applicable European standard can be found in EN 166. Eye wash bottle with pure water. Tightly fitting safety goggles.
The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place. Long sleeved clothing. The applicable European standard can be found in EN 14605.
See attached ES. Prevent entry into waterways, sewers, basements or confined areas. Local authorities should be advised if significant spillages cannot be contained. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No dangerous reaction known under conditions of normal use.
No hazards to be specially mentioned.
Excessive heat.
Strong oxidizing agents, water
Hydrogen Sulfide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The product should not be allowed to enter drains, water courses or the soil. Do not contaminate ponds, waterways or ditches with chemical or used container. Dispose of contents/ container to an approved waste disposal plant.
Disposal must be in accordance with applicable laws and regulations, and material characteristics at time of disposal.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for R10776A?
The signal word is no signal word.
What is the physical form of R10776A?
R10776A is a liquid with brown color. It has hydrocarbon-like odor.
What is R10776A used for?
Additive for car engine lubricating oil
What are the hazard statements for R10776A?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of R10776A?
The melting point is not determined and the boiling point is not determined.