Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
R10418A

Regulatory Identifiers

CAS Number
N/A
UFI Code
APJ3-M2FA-G00S-F005

Identified Uses

Viscosity Improvers

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL FRANCE logo

LUBRIZOL FRANCE

national supplier

25 QUAI DE FRANCE, CS 61062, 76173 ROUEN CEDEX, 76173, FR

(33) 02.35.58.14.00

http://www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 --- 50 - 100% Yes
Styrene-1,3-Butadiene polymer, hydrogenated --- 5 - 10% Yes

This substance has workplace exposure limit(s).

Notes

600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Wash with soap and water. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.

Eye contact

Any material that contacts the eye should be washed out immediately with water. If easy to do, remove contact lenses.

Ingestion

Treat symptomatically. Get medical attention.

Immediate Medical Attention

Get medical attention if symptoms occur (Skin); Get medical attention (Ingestion).

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

A solid stream of water will spread the burning material. Material creates a special hazard because it floats on water. See section 10 for additional information.

Instructions

No data available.

Firefighter Protection

Recommend wearing self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Avoid release to the environment.

Cleanup methods

Pick up free liquid for recycle and/or disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material. In case of spills, beware of slippery floors and surfaces.

Storage

Store away from incompatible materials. See section 10 for incompatible materials.

Hygiene

Observe good industrial hygiene practices.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.

Eyes

If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.

Respiratory

Use respirator with a combination organic vapor and high efficiency filter cartridge if recommended exposure limit is exceeded. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Long sleeve shirt is recommended. When working with heated material, wear heat protective clothing.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Water
Insoluble in water
Bulk Density
7.06 lb/cft (25 °C)
Freezing Point
No data available.
Softening Point
---
Physical State Data
liquid
Partition Coefficient
No data available.
Boiling Point
No data available.
Colour
Colorless to light yellow
Relative Density
0.828 - 0.868 (15.6 °C)
Flammability
No data available.
Odor
Mild
Cloud Point
---
Kinematic Viscosity
> 25 mm2/s (40 °C)
Appearance
Colorless to light yellow
State Under Standard Conditions
---
Dynamic Viscosity
---
Vapor Pressure
No data available.
Auto Ignition Temperature
No data available.
Relative Evaporation Rate
---
Flash Point
193 °C
Solubility
No data available.
Lower Explosive Limit
No data available.
Upper Explosive Limit
No data available.
Vapor Density
---
Melting Point
---
Solidification Point
---
Density
---
Physical State
liquid
Molecular Weight
---
Evaporation Rate
No data available.
Decomposition Temperature
No data available.
Properties Status
---
Ph
Not applicable
Explosive Limits
---
Form
liquid
Metal Corrosion
---
Crystallisation Point
---
Voc Content
No data available.
Odor Threshold
No data available.
Colour Intensity
---
Solubility In Fat
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

Do not expose to excessive heat, ignition sources, or oxidizing materials.

Incompatible

Strong oxidizing agents. Strong oxidizing agents. Strong acids. Oxidizing agents.

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, and other products of incomplete combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.

Disposal

Since emptied containers retain product residue, follow label warnings even after container is emptied.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for R10418A?

The signal word is no signal word.

What is the physical form of R10418A?

R10418A is a liquid appearing as colorless to light yellow with colorless to light yellow color. It has mild odor.

What is the solubility of R10418A?

No data available.

What is R10418A used for?

Viscosity Improvers