Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- R10059A
- Product Code
- 72255
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Viscosity modifier additive for lubricating oil
Uses advised against
This material should not be used for any other purpose than that recommended without expert advice.
Manufacturers & Suppliers
INFINEUM NETHERLANDS B.V.
national supplier
Herikerbergweg 238 Luna Arena 1101 CM Amsterdam The Netherlands
+44 1235 549501
http://www.infineum.com
Emergency Contacts
Emergency Contact
+33-4.4274.4690
Emergency Contact
+49-221-7499 3355
Emergency Contact
+39 019-2150 221
Emergency Contact
+44 1235 549777
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
All concentrations are weight percent units for liquids or volume percent units for gaseous products. Other ingredients are either not hazardous or are below the regulatory disclosure limit..
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 20 - 30% | Yes |
| N/A | --- | 20 - 30% | Yes |
| N/A | --- | 20 - 30% | Yes |
Notes
For the full text of the H-Statements mentioned in this Section, see Section 16. * These ingredients are either impurities or UVCB constituents.
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.
Symptoms: burns, pain
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.
Symptoms: eye irritation
Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.
Immediate Medical Attention
Seek medical advice if unconscious, if symptoms persist, in case of burns, or if eye irritation persists.
Medical Treatment
No hazards which require special first aid measures. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames
Do NOT use water jet.
Not classified as flammable or combustible, but will combust if ignited.
Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment. Material can create slippery conditions. Avoid contact with spilled material. Do not touch or walk through spilled material.
Dyke far ahead of liquid spill for later recovery and disposal.
No Exposure Scenario annex is attached to this safety data sheet. It is a non-classified mixture containing hazardous substances as detailed in Section 3; relevant information from Exposure Scenarios for the hazardous substances contained have been integrated into the core sections 1-16 of this SDS. Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.
Recover by pumping or with suitable absorbent. Wipe up with absorbent material (e.g. cloth, fleece). Clean contaminated floors and objects thoroughly while observing environmental regulations.
Materials: suitable absorbent, absorbent material (e.g. cloth, fleece)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharges. Dispose of rinse water in accordance with local and national regulations. Ensure all equipment is electrically grounded before beginning transfer operations. For safety reasons free water must be avoided when product is handled above 95degC. Free water is always detrimental to product quality.
Keep container tightly closed in a dry and well-ventilated place. No decomposition if stored and applied as directed. Do not reheat above: 100 °C (212 °F)
Smoking, eating and drinking should be prohibited in the application area.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No Exposure Scenario annex is attached to this safety data sheet. It is a non-classified mixture containing hazardous substances as detailed in Section 3; relevant information from Exposure Scenarios for the hazardous substances contained have been integrated into the core sections 1-16 of this SDS. No special requirements under ordinary conditions of use and with adequate ventilation.
Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. For prolonged or repeated contact use protective gloves. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Safety glasses The applicable European standard can be found in EN 166.
No personal respiratory protective equipment normally required. The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.
Long sleeved clothing The applicable European standard can be found in EN 14605.
No Exposure Scenario annex is attached to this safety data sheet. It is a non-classified mixture containing hazardous substances as detailed in Section 3; relevant information from Exposure Scenarios for the hazardous substances contained have been integrated into the core sections 1-16 of this SDS. Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No dangerous reaction known under conditions of normal use.
No hazards to be specially mentioned.
Excessive heat.
Strong oxidizing agents
No decomposition if used as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3257
- Shipping Name
- Elevated Temperature Liquid, n.o.s. (Aryl polyolefin)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for R10059A?
The signal word is no signal word.
What is the physical form of R10059A?
R10059A is a liquid with amber color. It has mild odor.
What is R10059A used for?
Viscosity modifier additive for lubricating oil
What is the melting point of R10059A?
The melting point is not determined and the boiling point is not determined.