Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- R10417A
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- V2S2-51P1-A00G-KY9H
Identified Uses
Passenger car motor oil additive.
Uses advised against
None identified.
Manufacturers & Suppliers
LUBRIZOL DEUTSCHLAND GMBH NIEDERLASSUNG HAMBURG
manufacturer
BILLBROOKDEICH 157 HAMBURG, D-22113 DE
+49 (0) 4032 3282-0
http://www.mylubrizol.com
Emergency Contacts
CHEMTREC
(+1) 703 527 3887
Emergency Contact
0 800 181 7059
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Mineral oil | --- | 20 - 50% | Yes |
| Calcium branched alkyl phenate sulphide (overbased) | --- | 5 - 10% | Yes |
| zinc O,O,O',O'-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate) EC: 218-679-9 | --- | 3 - 5% | Yes |
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | --- | 1 - 10% | Yes |
| Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr)esters, zinc salts EC: 283-392-8 | --- | 1 - 2.5% | Yes |
| 2,6-Di-tert-butylphenol EC: 204-884-0 | --- | 0.25 - 1% | Yes |
| Phenol, dodecyl-, branched EC: 310-154-3 | --- | 0.01 - 0.25% | Yes |
| Maleic anhydride EC: 203-571-6 | --- | 0.001% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove exposed person to fresh air if adverse effects are observed.
Take off contaminated clothing and wash before re-use. Wash with soap and water. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.
Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth. Get medical attention if symptoms occur.
Immediate Medical Attention
If irritation occurs, get medical assistance. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.
Do not use water jet as an extinguisher, as this will spread the fire.
No unusual fire or explosion hazards noted.
No data available.
Firefighter Protection
Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Personal Protective Equipment must be worn, see Personal Protection Section for PPE recommendations. Ventilate area if spilled in confined space or other poorly ventilated areas.
Dike far ahead of larger spill for later recovery and disposal.
Avoid release to the environment. Prevent further leakage or spillage if safe to do so.
Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Avoid environmental contamination. Open container in a well ventilated area. Avoid breathing vapors. Keep container closed when not in use and use with adequate ventilation.
Store away from incompatible materials. See section 10 for incompatible materials. Odorous and toxic fumes may form from the decomposition of this product if stored at temperatures in excess of 113 deg F (45 deg C) for extended periods of time or if heat sources in excess of 250 deg F (121 deg C) are used.
Observe good industrial hygiene practices.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material should be handled in enclosed vessels and equipment, in which case general (mechanical) room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air.
Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For short-term, transient exposures and splash protection, gloves with shorter breakthrough times may commonly be used. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential.
If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.
Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill cleanup sites. Use respirator with an organic vapor cartridge if exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.
Chemical resistant boots.
No data available. See section 6 for details.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
No data available.
Will not occur.
Do not expose to excessive heat, ignition sources, or oxidizing materials.
Strong mineral acids and strong oxidizing agents.
Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide , nitrogen oxides, and other products of incomplete combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Toxicity
Toxicity
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Results of PBT and vPvB assessment
Endocrine disrupting properties
Other adverse effects
Toxicity to Aquatic Plants
Toxicity to Aquatic Plants
Toxicity to Aquatic Plants
12.1 Toxicity
Toxicity
12.1 Toxicity
Toxicity
Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.3 Bioaccumulative potential
12.4 Mobility:
12.5 Results of PBT and vPvB assessment
12.6 Endocrine Disruption:
The substance is considered to have endocrine disrupting properties for the environment according to REACH Article 57(f).
12.7 Other adverse effects
The product contains an alkylated phenol impurity, but testing of the calcium phenate component indicates Aquatic Chronic 4 classification, overriding the impurity's classification for the final product. The product is classified as harmful to aquatic life with long lasting effects.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.
Dispose of packaging or containers in accordance with local, regional, national and international regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for R10417A?
The signal word is no signal word.
What is the physical form of R10417A?
R10417A is a liquid appearing as dark brown with dark brown color. It has mild odor.
What is R10417A used for?
Passenger car motor oil additive.
What are the hazard statements for R10417A?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects.