NextSDS Logo
Safety Data Sheet EN

Infineum C9610

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Infineum C9610
Product Code
74533

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Component of fuel additives

Uses advised against

This material should not be used for any other purpose than that recommended without expert advice.

Manufacturers & Suppliers

INFINEUM ITALIA S.R.L. logo

INFINEUM ITALIA S.R.L.

manufacturer

Strada di Scorrimento 2 17047 Vado Ligure (SV) – Italy

+39 019 2150 1

http://www.infineum.com

Emergency Contacts

Emergency Contact

+33-4.4274.4690

Emergency Contact

+49-221-7499 3355

Emergency Contact

+39 019-2150 221

Emergency Contact

+44 1235 549777

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

All concentrations are weight percent units for liquids or volume percent units for gaseous products.

Chemical Name CAS Number Concentration Hazardous
N/A --- 1 - 10% Yes
N/A --- 1 - 10% Yes

For the full text of the H-Statements mentioned in this Section, see Section 16.

Notes

Other ingredients are either not hazardous or are below the regulatory disclosure limit.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Immediate Medical Attention

No hazards which require special first aid measures. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.

Medical Treatment

No hazards which require special first aid measures. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames

Unsuitable media

Do NOT use water jet.

Specific hazards

Not classified as flammable or combustible, but will combust if ignited.

Instructions

Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Large spill

Dyke far ahead of liquid spill for later recovery and disposal.

Environmental

Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Recover by pumping or with suitable absorbent. Wipe up with absorbent material (e.g. cloth, fleece). Clean contaminated floors and objects thoroughly while observing environmental regulations.

Materials: suitable absorbent, absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations. Normal measures for preventive fire protection. Products may load from Infineum manufacturing site above the standard loading/unloading range.

Storage

Keep container tightly closed in a dry and well-ventilated place. No decomposition if stored and applied as directed. Do not reheat above: 95 °C (203 °F)

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. For prolonged or repeated contact use protective gloves.

Eyes

The applicable European standard can be found in EN 166. Safety glasses

Respiratory

The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387. No personal respiratory protective equipment normally required.

Skin/Body

The applicable European standard can be found in EN 14605. Long sleeved clothing

Environmental

Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
brown
Colour Intensity
---
Form
viscous
Odor
hydrocarbon-like
Odor Threshold
not determined
Ph
Not applicable
Melting Point
not determined
Boiling Point
not determined
Flash Point
230 °C (446 °F)
Freezing Point
-3 °C (27 °F)
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable
Vapor Pressure
< 0,1 hPa (< 0,1 mmHg) at 20 °C (68 °F)
Vapor Density
not determined
Relative Density
not determined
Bulk Density
Not applicable
Density
1,015 g/cm3 at 15 °C (59 °F)
Flammability
not determined
Upper Explosive Limit
not determined
Lower Explosive Limit
not determined
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
not determined
Solubility
---
Partition Coefficient
not determined
Solubility In Water
< 0,0001 g/l
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
204 mm2/s at 100 °C (212 °F) 12040 mm2/s at 20 °C (68 °F) 2813 mm2/s at 40 °C (104 °F) 1667 mm2/s at 50 °C (122 °F) 633 mm2/s at 70 °C (158 °F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No hazards to be specially mentioned.

Avoid

Excessive heat.

Incompatible

Strong oxidizing agents

Decomposition

No decomposition if used as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Infineum C9610?

The signal word is no signal word.

What is the physical form of Infineum C9610?

Infineum C9610 is a liquid with brown color. It has hydrocarbon-like odor.

What is Infineum C9610 used for?

Component of fuel additives

What is the melting point of Infineum C9610?

The melting point is not determined and the boiling point is not determined.