NextSDS Logo
In

Infineum C9902

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Infineum C9902
Product Code
33801

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Component of lubricant additives
Uses Advised Against
This material should not be used for any other purpose than that recommended without expert advice.

Overview

Infineum C9902 commonly used component of lubricant additives.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

INFINEUM NETHERLANDS B.V. company logo - Safety Data Sheet supplier organization

INFINEUM NETHERLANDS B.V.

global supplier

๐Ÿ“

Herikerbergweg 238 Luna Arena 1101 CM Amsterdam The Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+44 1235 549501

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+33-4.4274.4690

๐ŸŒ

FR

Emergency Contact

๐Ÿ“ž

+49-221-7499 3355

๐ŸŒ

DE

Emergency Contact

๐Ÿ“ž

+39 019-2150 221

๐ŸŒ

IT

Emergency Contact

๐Ÿ“ž

+44 1235 549777

๐ŸŒ

GB

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

๐Ÿ–๏ธ Skin Contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.

Symptoms:

Pain (in case of burns).

๐Ÿ‘๏ธ Eye Contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.

๐Ÿฝ๏ธ Ingestion/Swallowing

Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

๐Ÿšจ Immediate Medical Attention Required

Seek medical advice if unconscious, if symptoms persist, if eye irritation persists, or in case of burns.

Medical Treatment

No hazards which require special first aid measures. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
No information available.
๐Ÿ‘ƒ Odor
No information available.
๐Ÿ“Š Odor Threshold
not determined
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
not determined
Critical Property
๐Ÿ’จ Boiling Point
not determined
Critical Property
๐Ÿ”ฅ Flash Point
140 C (284 F)
Critical Property
๐Ÿ“Š Freezing Point
not determined
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable
๐Ÿ’จ Vapor Pressure
< 0,1 hPa (< 0,1 mmHg) at 20 C (68 F)
๐Ÿ“Š Vapor Density
not determined
๐Ÿ“Š Relative Density
not determined
๐Ÿ“Š Bulk Density
Not applicable
โš–๏ธ Density
0,8292 g/cm3 at 50 C (122 F)
Critical Property
๐Ÿ”ฅ Flammability
not determined
๐Ÿ“Š Upper Explosive Limit
not determined
๐Ÿ“Š Lower Explosive Limit
not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not applicable
๐Ÿ“Š Decomposition Temperature
not determined
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
not determined
๐Ÿ“Š Solubility In Water
< 0,0001 g/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
10 - 100 mm2/s at 100 C (212 F)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No special requirements under ordinary conditions of use and controls with adequate ventilation.

๐Ÿงค Hand Protection

Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. For prolonged or repeated contact use protective gloves. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

๐Ÿ‘๏ธ Eye Protection

Safety glasses The applicable European standard can be found in EN 166.

๐Ÿ˜ท Respiratory Protection

No personal respiratory protective equipment normally required. The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.

๐Ÿฆบ Skin/Body Protection

Long sleeved clothing The applicable European standard can be found in EN 14605.

๐ŸŒ Environmental Exposure Controls

Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN3257

๐Ÿ“ฆ Proper Shipping Name

Elevated Temperature Liquid, n.o.s. (Polyolefin)

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Infineum C9902?

The signal word for this substance is "no signal word".

What is the physical form of Infineum C9902?

Infineum C9902 is a liquid with colourless color. It has no information available. odor.

What is Infineum C9902 used for?

Component of lubricant additives

What is the melting point of Infineum C9902?

The melting point is not determined and the boiling point is not determined.