NextSDS Logo
Safety Data Sheet EN

D122727

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
D122727
Product Code
73336

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Additive for car engine lubricating oil

Uses advised against

This material should not be used for any other purpose than that recommended without expert advice.

Manufacturers & Suppliers

INFINEUM FRANCE S.N.C. logo

INFINEUM FRANCE S.N.C.

national supplier

Chemin Départemental 54 13130 BERRE L'ETANG

+33 4 42 74 57 01

http://www.infineum.com

Emergency Contacts

Emergency Contact

+33-4.4274.4690

Emergency Contact

+49-221-7499 3355

Emergency Contact

+39 019-2150 221

Emergency Contact

+44 1235 549777

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P501 Dispose of contents/ container to an approved waste disposal plant.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

All concentrations are weight percent units for liquids or volume percent units for gaseous products.

Chemical Name CAS Number Concentration Hazardous
N/A --- 1 - 10% Yes
N/A --- 3 - 6.25% Yes
N/A --- 1 - 10% Yes
N/A --- 1 - 10% Yes
N/A --- 1 - 10% Yes
N/A --- 0.1 - 1% Yes

Notes

Other ingredients are either not hazardous or are below the regulatory disclosure limit.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician. If breathing has stopped, assist ventilation with a mechanical device. Do not use mouth-to-mouth resuscitation if exposure to hydrogen sulphide is suspected.

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.

Symptoms: burns

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.

Symptoms: eye irritation

Ingestion

Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Immediate Medical Attention

Seek medical advice if unconscious or if symptoms persist. Get medical advice/ attention if eye irritation persists. Show this safety data sheet to the doctor in attendance. The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

Medical Treatment

Show this safety data sheet to the doctor in attendance. The first aid procedure should be established in consultation with the doctor responsible for industrial medicine. If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames

Unsuitable media

High volume water jet

Specific hazards

Not classified as flammable or combustible, but will combust if ignited. Exposure to decomposition products may be a hazard to health.

Instructions

Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus. Exposure to decomposition products may be a hazard to health. Fire-fighters should exercise extreme caution in enclosed spaces due to the possible presence of toxic decomposition and combustion products. Self-contained full-face overpressure breathing apparatus should be used in enclosed spaces. Use standard body protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Use personal protective equipment. Material can create slippery conditions. For personal protection see section 8. Avoid contact with spilled material. Do not touch or walk through spilled material.

Large spill

Dyke far ahead of liquid spill for later recovery and disposal.

Environmental

See attached ES. Prevent entry into waterways, sewers, basements or confined areas. Local authorities should be advised if significant spillages cannot be contained. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Prevent further leakage or spillage if safe to do so. Recover by pumping or with suitable absorbent. Wipe up with absorbent material (e.g. cloth, fleece). Keep in suitable, closed containers for disposal. Clean contaminated floors and objects thoroughly while observing environmental regulations.

Materials: suitable absorbent, absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations. This product contains Zinc Dialkyl DithioPhosphate (ZDDP), a thermally sensitive substance. Do not reheat above the maximum loading temperature. Higher temperatures can result in exothermic decomposition of the ZDDP leading to the release of highly toxic hydrogen sulphide and possibly extremely odorous alkyl mercaptans. Alkyl mercaptans can be smelled at extremely low concentrations, and vapours may travel for many miles at detectable concentrations. These decomposition vapours are also flammable and may suddenly ignite when mixed with air in the presence of ignition sources such as sparks or flames. Caution must be exercised when heating this product. When heated, product temperature should be constantly monitored. Product should be stored below the recommended maximum loading / unloading temperature to avoid degradation of product quality and eventually decomposition. Warning: If this material is overheated, especially in the presence of water, hydrogen sulphide may be released; this can cause rapid respiratory collapse, coma and death without necessarily any warning odour being sensed. If decomposition is suspected, or if the product has been overheated, do not open the container, discontinue heating and secure the unit. Initiate emergency procedures, taking all necessary precautions to avoid exposure to noxious or flammable gases (e.g. hydrogen sulphide), such as evacuation of contaminated areas, and use of suitable respiratory protection.

Storage

Keep container tightly closed in a dry and well-ventilated place. No decomposition if stored and applied as directed. Do not reheat above: 65 °C (149 °F) Storage temperature : <= 60 °C (140 °F)

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection. These decomposition vapours are also flammable and may suddenly ignite when mixed with air in the presence of ignition sources such as sparks or flames.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

See attached ES No special requirements under ordinary conditions of use and with adequate ventilation. If decomposition is suspected, or if the product has been overheated, do not open the container, discontinue heating and secure the unit. Initiate emergency procedures, taking all necessary precautions to avoid exposure to noxious or flammable gases (e.g. hydrogen sulphide), such as evacuation of contaminated areas, and use of suitable respiratory protection.

Hands

Polyvinyl alcohol or nitrile- butyl-rubber gloves Before removing gloves clean them with soap and water. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

Eyes

The applicable European standard can be found in EN 166. Eye wash bottle with pure water Tightly fitting safety goggles Ensure that eyewash stations and safety showers are close to the workstation location.

Respiratory

The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.

Skin/Body

Impervious clothing Choose body protection according to the amount and concentration of the dangerous substance at the work place. Long sleeved clothing The applicable European standard can be found in EN 14605.

Environmental

See attached ES Prevent entry into waterways, sewers, basements or confined areas. Local authorities should be advised if significant spillages cannot be contained. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
0,943 g/cm³ at 15 °C (59 °F)
Physical State Data
liquid
Voc Content
no VOC duties
Upper Explosive Limit
not determined
Kinematic Viscosity
196 mm2/s at 100 °C (212 °F) 4387 mm2/s at 40 °C (104 °F)
Partition Coefficient
not determined
Odor Threshold
not determined
Relative Evaporation Rate
---
Properties Status
---
Solubility In Fat
---
Flash Point
161 °C (322 °F)
Auto Ignition Temperature
Not applicable
Odor
hydrocarbon-like
State Under Standard Conditions
---
Lower Explosive Limit
not determined
Boiling Point
not determined
Softening Point
---
Molecular Weight
---
Colour
brown
Dynamic Viscosity
---
Solidification Point
---
Flammability
not determined
Vapor Density
not determined
Colour Intensity
---
Decomposition Temperature
not determined
Relative Density
0,944 at 15,6 °C (60,1 °F)
Cloud Point
---
Solubility
---
Crystallisation Point
---
Explosive Limits
---
Physical State
liquid
Form
viscous
Freezing Point
not determined
Vapor Pressure
< 0,1 hPa (< 0,1 mmHg) at 20 °C (68 °F)
Solubility In Water
< 0,0001 g/l
Ph
Not applicable
Metal Corrosion
---
Melting Point
not determined
Evaporation Rate
Not applicable
Appearance
---
Bulk Density
Not applicable
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No hazards to be specially mentioned.

Avoid

Excessive heat.

Incompatible

Strong oxidizing agents, water

Decomposition

Hydrogen Sulfide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for D122727?

The signal word is no signal word.

What is the physical form of D122727?

D122727 is a liquid with brown color. It has hydrocarbon-like odor.

What is D122727 used for?

Additive for car engine lubricating oil

What are the hazard statements for D122727?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of D122727?

The melting point is not determined and the boiling point is not determined.

Compliance Scanner

Scan your compliance