Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SpermMar Test IgA
- Product Form
- Mixture
- Product Code
- SPMA_S, SPMA_C
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial/Professional use spec : For professional use only Use of the substance/mixture : Diagnostic kit for the detection of sperm antibodies of the IgA class in human semen
Uses advised against
No additional information available
Manufacturers & Suppliers
FertiPro NV
manufacturer
Industriepark Noord 32, 8730 Beernem, Belgium
Emergency Contacts
Emergency Contact
+3250791805
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ultrapure water EC: 231-791-2 | 7732-18-5 | 90 - 99% | No |
| Latex beads coated with anti-IgA | --- | 1 - 5% | No |
| Sodium Chloride EC: 231-598-3 | 7647-14-5 | 0.1 - 1% | No |
| Glycine EC: 200-272-2 | 56-40-6 | 0.1 - 1% | No |
| Bovine serum albumin EC: 232-936-2 | 9048-46-8 | 0.1 - 1% | No |
| Sodium Hydroxide EC: 215-185-5 | 1310-73-2 | 0.1% | Yes |
| Sodium azide EC: 247-852-1 | 26628-22-8 | 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Assure fresh air breathing. Allow the victim to rest.
Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. Wash affected clothing before reuse.
Remove contact lenses, if possible. Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persist.
Symptoms: pain, blinking or redness
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.
Immediate Medical Attention
Obtain emergency medical attention (for ingestion). Obtain medical attention if pain, blinking or redness persist (for eye contact).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Dry powder. Carbon dioxide. Water spray. Sand.
Do not use a heavy water stream.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Ventilate area.
Prevent entry to sewers and public waters.
Soak up spills as soon as possible. Collect spillage. Store away from other materials.
Related Products
Similar products with comparable safety profiles
SpermMar IgG: Positive and Negative control
---
latex bead solution (SpermMar IgA Latex)
---
latex bead solution (SpermMar IgG Latex) + antiserum (SpermMar IgG Antiserum)
---
PureSperm®100
---
GM501 SpermMobil
---
PureSperm® Wash
---
PureSperm 40, PureSperm 80, PureSperm 90
---
Salmonella Latex Test
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour.
Keep only in the original container in a cool, well ventilated place away from (sun)light. Keep container closed when not in use. Do not freeze. Do not use after expiry date.
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle in accordance with good industrial hygiene and safety. Avoid all unnecessary exposure
Wear protective gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to meet the specifications of Regulation EU 2016/425 and the standard EN374.
Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).
Wear appropriate mask. Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Complete suit protecting against chemicals, flame retardant antistatic protective clothing. The type of protection must be selected according to the concentration and volume of the dangerous substance at the specific workplace.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable after transport (max. 7 days) at elevated (≤37°C) temperature. Stable for 12 months from date of manufacturing.
No additional information available
Not established.
Direct (sun)light. Extremely high or low temperatures. Open fire.
Strong acids. Strong bases.
Smoke. Carbon monoxide. Carbon dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SpermMar Test IgA?
The signal word is no signal word.
What is the physical form of SpermMar Test IgA?
SpermMar Test IgA is a liquid with white color. It has odourless odor.
What is the solubility of SpermMar Test IgA?
Not available
What is SpermMar Test IgA used for?
Industrial/Professional use spec : For professional use only Use of the substance/mixture : Diagnostic kit for the detection of sperm antibodies of the IgA class in human semen
What is the melting point of SpermMar Test IgA?
The melting point is Not available and the boiling point is Not available.