NextSDS Logo
Safety Data Sheet EN

SpermMar Test IgA

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SpermMar Test IgA
Product Form
Mixture
Product Code
SPMA_S, SPMA_C

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial/Professional use spec : For professional use only Use of the substance/mixture : Diagnostic kit for the detection of sperm antibodies of the IgA class in human semen

Uses advised against

No additional information available

Manufacturers & Suppliers

F

FertiPro NV

manufacturer

Industriepark Noord 32, 8730 Beernem, Belgium

Emergency Contacts

Emergency Contact

+3250791805

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Ultrapure water EC: 231-791-2 7732-18-5 90 - 99% No
Latex beads coated with anti-IgA --- 1 - 5% No
Sodium Chloride EC: 231-598-3 7647-14-5 0.1 - 1% No
Glycine EC: 200-272-2 56-40-6 0.1 - 1% No
Bovine serum albumin EC: 232-936-2 9048-46-8 0.1 - 1% No
Sodium Hydroxide EC: 215-185-5 1310-73-2 0.1% Yes
Sodium azide EC: 247-852-1 26628-22-8 0.1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Assure fresh air breathing. Allow the victim to rest.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. Wash affected clothing before reuse.

Eye contact

Remove contact lenses, if possible. Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persist.

Symptoms: pain, blinking or redness

Ingestion

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

Immediate Medical Attention

Obtain emergency medical attention (for ingestion). Obtain medical attention if pain, blinking or redness persist (for eye contact).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam. Dry powder. Carbon dioxide. Water spray. Sand.

Unsuitable media

Do not use a heavy water stream.

Instructions

Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Ventilate area.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Soak up spills as soon as possible. Collect spillage. Store away from other materials.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour.

Storage

Keep only in the original container in a cool, well ventilated place away from (sun)light. Keep container closed when not in use. Do not freeze. Do not use after expiry date.

Hygiene

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle in accordance with good industrial hygiene and safety. Avoid all unnecessary exposure

Hands

Wear protective gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to meet the specifications of Regulation EU 2016/425 and the standard EN374.

Eyes

Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).

Respiratory

Wear appropriate mask. Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Complete suit protecting against chemicals, flame retardant antistatic protective clothing. The type of protection must be selected according to the concentration and volume of the dangerous substance at the specific workplace.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
White
Colour Intensity
---
Form
---
Odor
Odourless
Odor Threshold
Not available
Ph
7,6-9
Melting Point
Not available
Boiling Point
Not available
Flash Point
Not available
Freezing Point
Not available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not available
Vapor Density
---
Relative Density
Not available
Bulk Density
---
Density
Not available
Flammability
Non flammable
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
---
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Not available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable after transport (max. 7 days) at elevated (≤37°C) temperature. Stable for 12 months from date of manufacturing.

Reactivity

No additional information available

Hazardous reactions

Not established.

Avoid

Direct (sun)light. Extremely high or low temperatures. Open fire.

Incompatible

Strong acids. Strong bases.

Decomposition

Smoke. Carbon monoxide. Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SpermMar Test IgA?

The signal word is no signal word.

What is the physical form of SpermMar Test IgA?

SpermMar Test IgA is a liquid with white color. It has odourless odor.

What is the solubility of SpermMar Test IgA?

Not available

What is SpermMar Test IgA used for?

Industrial/Professional use spec : For professional use only Use of the substance/mixture : Diagnostic kit for the detection of sperm antibodies of the IgA class in human semen

What is the melting point of SpermMar Test IgA?

The melting point is Not available and the boiling point is Not available.