NextSDS Logo
Safety Data Sheet EN

MC-Injekt GL-95 - Komponente A 3

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MC-Injekt GL-95 - Komponente A 3

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Construction chemicals, Injektion

Manufacturers & Suppliers

M

MC-Bauchemie Müller GmbH & Co. KG

manufacturer

Am Kruppwald 1-8, D-46238 Bottrop

+49(0)2041-101-0

M

MC-Bauchemie AG

manufacturer

Hagackerstr. 10, CH-8953 Dietikon

+44-7400510

Emergency Contacts

MCR

+49 / (0)700 24112112

Emergency Contact

+48612864565

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with harmless additions.

For the wording of the listed hazard phrases refer to section 16.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Skin contact

The product is not skin irritating.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

In case of persistent symptoms consult doctor.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water jet. Fight larger fires with water jet or alcohol-resistant foam.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Dilute with much water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required.

Storage

No special requirements.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Not required.

Eyes

Not required.

Respiratory

Not required.

Skin/Body

Impervious protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Decomposition Temperature
Not determined.
Solubility In Water
Fully miscible
Bulk Density
---
Partition Coefficient
Not determined.
Flammability
Not applicable.
Relative Evaporation Rate
---
Form
Fluid
Solubility
---
Molecular Weight
---
Auto Ignition Temperature
305 °C
Melting Point
Not determined
Properties Status
---
Dynamic Viscosity
2 mPas
Kinematic Viscosity
Not determined.
Flash Point
Not applicable
Freezing Point
Not determined
State Under Standard Conditions
---
Crystallisation Point
---
Lower Explosive Limit
Not determined.
Odor
Characteristic
Colour
Light yellow
Ph
Not determined.
Density
1.06 g/cm³
Vapor Pressure
23 hPa
Physical State Data
liquid
Explosive Limits
---
Boiling Point
100 °C
Evaporation Rate
---
Cloud Point
---
Solidification Point
---
Appearance
---
Softening Point
---
Relative Density
---
Physical State
Fluid
Voc Content
---
Vapor Density
---
Solubility In Fat
---
Odor Threshold
Not determined.
Colour Intensity
---
Upper Explosive Limit
Not determined.
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MC-Injekt GL-95 - Komponente A 3?

The signal word is no signal word.

What is the physical form of MC-Injekt GL-95 - Komponente A 3?

MC-Injekt GL-95 - Komponente A 3 is a fluid with light yellow color. It has characteristic odor.

What is MC-Injekt GL-95 - Komponente A 3 used for?

Construction chemicals, Injektion

What is the melting point of MC-Injekt GL-95 - Komponente A 3?

The melting point is Not determined and the boiling point is 100 °C.