Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MC-Injekt 1264 compact - Komponente B
- Product Code
- 2992
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Epoxy resin, Injektion, Hardening agent/ Curing agent
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
MC-Bauchemie Müller GmbH & Co. KG
manufacturer
Am Kruppwald 1-8, D-46238 Bottrop
+49(0)2041-101-0
MC-Bauchemie AG
manufacturer
Hagackerstr. 10, CH-8953 Dietikon
+44-7400510
Emergency Contacts
MCR
+49 / (0)700 24112112
Emergency Contact
+48612864565
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Binding agent with colouring agents. Mixture consisting of the following components.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polyamine-Addukt | --- | 25 - 50% | Yes |
| 3-aminomethyl-3,5,5-trimethylcyclohexylamine EC: 220-666-8 | 2855-13-2 | 25 - 50% | Yes |
| Benzyl alcohol EC: 202-859-9 | 100-51-6 | 25% | Yes |
| Polyoxypropylenediamine | 9046-10-0 | 1 - 2.5% | Yes |
| 2,4,6-tris(dimethylaminomethyl)phenol EC: 202-013-9 | 90-72-2 | 1.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air.
Instantly wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. Seek medical treatment.
Drink copious amounts of water and provide fresh air. Instantly call for doctor.
Immediate Medical Attention
Instantly call for doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire fighting measures that suit the environment.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Prevent material from reaching sewage system, holes and cellars.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
MC-Injekt 1264 compact - Komponente A
---
MC-Injekt 2300 top - Komponente B
---
MC-Injekt GL-95 TX - Komponente B 1
---
MC-Injekt GL-95 TX TR - Komponente B
---
MC-Injekt GL-95 - Komponente A 3
---
MC-Injekt GL-95 - Komponente A 1
---
MC-Injekt GL-95 TR - Komponente A 2
---
Akepox 5010 Component B
UFI: N1AA-2R3V-FY04-TGPT
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Store in cool, dry place in tightly closed containers. Open and handle container with care.
Store in cool, dry place in tightly closed containers. Keep container tightly sealed.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. After use of gloves apply skin-cleaning agents and skin cosmetics. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses. Tightly sealed safety glasses.
Protective work clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2735
- Shipping Name
- AMINES, LIQUID, CORROSIVE, N.O.S. (ISOPHORONEDIAMINE, Polyoxypropylenediamine)
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MC-Injekt 1264 compact - Komponente B?
The signal word is danger.
What is the physical form of MC-Injekt 1264 compact - Komponente B?
MC-Injekt 1264 compact - Komponente B is a fluid appearing as transparent with transparent color. It has amine-like odor.
What is MC-Injekt 1264 compact - Komponente B used for?
Epoxy resin, Injektion, Hardening agent/ Curing agent
What are the hazard statements for MC-Injekt 1264 compact - Komponente B?
This substance has 4 hazard statements:
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of MC-Injekt 1264 compact - Komponente B?
The melting point is Not determined and the boiling point is 205 °C.