NextSDS Logo
Safety Data Sheet EN

MC-Injekt GL-95 - Komponente A 1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MC-Injekt GL-95 - Komponente A 1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Construction chemicals, Injektion

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

M

MC-Bauchemie Müller GmbH & Co. KG

manufacturer

Am Kruppwald 1-8, D-46238 Bottrop

+49(0)2041-101-0

M

MC-Bauchemie AG

manufacturer

Hagackerstr. 10, CH-8953 Dietikon

+44-7400510

Emergency Contacts

MCR

+49 / (0)700 24112112

Emergency Contact

+48612864565

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with harmless additions. Solution of monomeres diluted in water.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.

Ingestion

In case of persistent symptoms consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire fighting measures that suit the environment.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Dilute with much water.

Cleanup methods

Dilute with much water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat and direct sunlight. Rust and any other oxidative pollutions may lead to the polymerisation of component A 1.

Storage

No special requirements.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Not required.

Eyes

Not required.

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Solubility
---
Physical State Data
liquid
State Under Standard Conditions
---
Solubility In Fat
---
Dynamic Viscosity
---
Bulk Density
---
Molecular Weight
---
Density
1.2 g/cm³
Physical State
Fluid
Odor
Odourless
Flammability
---
Colour
Blue
Crystallisation Point
---
Appearance
Blue
Colour Intensity
---
Solidification Point
---
Solubility In Water
Fully miscible
Lower Explosive Limit
---
Metal Corrosion
---
Vapor Density
---
Properties Status
---
Softening Point
---
Melting Point
Not applicable
Explosive Limits
---
Kinematic Viscosity
---
Decomposition Temperature
---
Odor Threshold
---
Auto Ignition Temperature
Product is not selfigniting.
Boiling Point
---
Evaporation Rate
---
Relative Density
---
Upper Explosive Limit
---
Flash Point
Not applicable
Form
Fluid
Partition Coefficient
---
Relative Evaporation Rate
---
Vapor Pressure
---
Freezing Point
Not applicable
Voc Content
---
Ph
6.0-6.5
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MC-Injekt GL-95 - Komponente A 1?

The signal word is no signal word.

What is the physical form of MC-Injekt GL-95 - Komponente A 1?

MC-Injekt GL-95 - Komponente A 1 is a fluid appearing as blue with blue color. It has odourless odor.

What is MC-Injekt GL-95 - Komponente A 1 used for?

Construction chemicals, Injektion

What is the melting point of MC-Injekt GL-95 - Komponente A 1?

The melting point is Not applicable .