Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ICAPLINK A522
- Product Code
- 4216
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial user (SU3), Catalyst
Manufacturers & Suppliers
ICAP-SIRA CHEMICALS AND POLYMERS S.P.A.
manufacturer
Via F.Corridoni 19 20015 Parabiago (MI) Italia
+39 0331 496111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| toluene EC: 203-625-9 | 108-88-3 | 40 - 50% | Yes |
| 2-methylpropan-1-ol; iso-butanol EC: 201-148-0 | 78-83-1 | 30 - 40% | Yes |
| Idrogenofosfato di dibutile EC: 203-509-8 | 107-66-4 | 12.5 - 15% | Yes |
| Diidrogenofosfato di butile EC: 216-604-4 | 1623-15-0 | 10 - 12.5% | Yes |
| phosphoric acid ... %, orthophosphoric acid ... % EC: 231-633-2 | 7664-38-2 | 0.25 - 0.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing is irregular or stopped, administer artificial respiration. In case of inhalation, consult a doctor immediately and show him packing or label.
OBTAIN IMMEDIATE MEDICAL ATTENTION. Remove contaminated clothing immediately and dispose off safely. Wash thoroughly the body (shower or bath). After contact with skin, wash immediately with soap and plenty of water.
After contact with the eyes, rinse with water with the eyelids open for a sufficient length of time, then consult an ophthalmologist immediately. Protect uninjured eye.
Do NOT induce vomiting.
Immediate Medical Attention
OBTAIN IMMEDIATE MEDICAL ATTENTION. In case of accident or unwellness, seek medical advice immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
use dry powder, CO2, foam for extinction.
Water. In case of fire of insoluble products / immiscible in water, the use of water, increase the risk of propagation of the area of fire.
Do not inhale explosion and combustion gases. Burning produces heavy smoke. When heated (decomposition) or in case of fire may liberate carbon oxides, gases and vapors which are dangerous to health.
Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear personal protection equipment. Remove all sources of ignition. Wear breathing apparatus if exposed to vapours/dusts/aerosols. Provide adequate ventilation. Use appropriate respiratory protection.
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
Wash with plenty of water.
Materials: absorbing material, organic, sand
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes, inhalation of vapours and mists. Don't use empty container before they have been cleaned. Before making transfer operations, assure that there aren't any incompatible material residuals in the containers. Contamined clothing should be changed before entering eating areas. Do not eat or drink while working.
Always keep the containers tightly closed. Always keep in a well ventilated place. Keep away from unguarded flame, sparks, and heat sources. Avoid direct exposure to sunlight. Keep away from food, drink and feed. Cool and adequately ventilated.
Contamined clothing should be changed before entering eating areas. Do not eat or drink while working.
Keep away from unguarded flame, sparks, and heat sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation to maintain air contaminants below exposure limits (it is advisable to work under vacuum system). Install a closed circuit with forced ventilation if possible; failing this, use personal protective equipment suitable for the type of processing.
Use protective gloves that provides comprehensive protection, e.g. P.V.C., neoprene or rubber. Protective gloves (EN 374): in case risk of skin contact with the product, the use of protective gloves checked according to EN 374, is considered sufficient protection. Protective gloves should be tested before use to verify their suitability with respect to the specific needs of the workplace (eg mechanical stability, chemical compatibility and antistatic properties). Follow the manufacturer's instructions and information relating to the use, storage, care and replacement of protective gloves. Protective gloves shall be replaced immediately when physically damaged or worn.
Use close fitting safety goggles, don't use eye lens.
Use adequate protective respiratory equipment. Ensure good ventilation to maintain air contaminants below exposure limits. Use respiratory protection filters for gas / vapor (Type A / AX brown, ref. Standard EN 141) as a function of the levels of occupational exposure to chemical agents.
Chemical protection clothing.
Make sure there are no leaks from containers, lines and equipment users. Prevent spills into public sewers or the immediate environment. Do not empty into drains; dispose of this material and its container at a collection point for hazardous waste and in accordance with local regulations. Refer to applicable national and Community legislation concerning environmental protection, waste water, soil pollution and integrated pollution prevention and control (ex. IPPC). Check whether the activity that uses the product falls within the scope of Directive 96/61/EC (IPPC). The emissions from ventilation or work process equipment should be checked to ensure compliance with the directives of the binding legislation on environmental protection. In some cases, to reduce emissions, might be needed maintenance or technical plant modifications.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions
Stable under normal conditions
Stable under normal conditions.
Avoid contact with combustible materials. The product could catch fire.
None known. When heated (decomposition) or in case of fire may liberate carbon oxides, gases and vapors which are dangerous to health.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2924
- Shipping Name
- Flammable liquid, corrosive, n.o.s.
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ICAPLINK A522?
The signal word is danger.
What is the physical form of ICAPLINK A522?
ICAPLINK A522 is a liquid appearing as liquid . It has solvent odor.
What is ICAPLINK A522 used for?
Industrial user (SU3), Catalyst
What are the hazard statements for ICAPLINK A522?
This substance has 6 hazard statements:
- H225: Highly flammable liquid and vapour.
- H314: Causes severe skin burns and eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H361: Suspected of damaging fertility or the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of ICAPLINK A522?
The melting point is N.A. and the boiling point is 108-111°C.