Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ICAPLINK A520
- Product Code
- 4247
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial user (SU3) Cross Linking Agent.
Uses advised against
Non utilizzare per usi diversi da quelli indicati.
Manufacturers & Suppliers
ICAP-SIRA CHEMICALS AND POLYMERS S.P.A.
manufacturer
Via F.Corridoni 19 20015 Parabiago (MI) Italia
Emergency Contacts
ICAP-SIRA Chemicals and polymers S.P.A.
+39 0331 496111
Monday to Friday 08.00-12.30 14.00-18.00 UTC/GMT +1
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-methylpropan-1-ol; iso-butanol EC: 201-148-0 | 78-83-1 | 20 - 25% | Yes |
| formaldehyde EC: 200-001-8 | 50-00-0 | 0.5 - 1% | Yes |
In case of the REACH registration numbers do not appear, the substance is exempted from registration, does not reach the threshold of minimum volume for recording or the recording date is not yet forthcoming.
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of inhalation, consult a doctor immediately and show him packing or label.
OBTAIN IMMEDIATE MEDICAL ATTENTION. Remove contaminated clothing immediately and dispose off safely. Wash thoroughly the body (shower or bath). After contact with skin, wash immediately with soap and plenty of water.
After contact with the eyes, rinse with water with the eyelids open for a sufficient length of time, then consult an ophthalmologist immediately. Protect uninjured eye.
Do not under any circumstances induce vomiting. OBTAIN A MEDICAL EXAMINATION IMMEDIATELY.
Immediate Medical Attention
OBTAIN IMMEDIATE MEDICAL ATTENTION. Consult a doctor immediately. Consult an ophthalmologist immediately. OBTAIN A MEDICAL EXAMINATION IMMEDIATELY.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire: use dry powder, CO2, foam for extinction.
Never use water.
Do not inhale explosion and combustion gases. Burning produces heavy smoke. When heated (decomposition) or in case of fire may liberate carbon oxides, gases and vapors which are dangerous to health.
Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear personal protection equipment. Remove all sources of ignition. Wear breathing apparatus if exposed to vapours/dusts/aerosols. Provide adequate ventilation. Use appropriate respiratory protection.
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes, inhalation of vapours and mists. Exercise the greatest care when handling or opening the container. Don't use empty container before they have been cleaned. Before making transfer operations, assure that there aren't any incompatible material residuals in the containers.
Store at below 20 °C. Keep away from unguarded flame and heat sources. Avoid direct exposure to sunlight. Keep away from food, drink and feed. Cool and adequately ventilated.
Contamined clothing should be changed before entering eating areas. Do not eat or drink while working.
Keep away from unguarded flame, sparks, and heat sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Always provide good ventilation to maintain air contaminants below exposure limits (it is advisable to work under vacuum system). Install a closed circuit with forced ventilation if possible; failing this, use personal protective equipment suitable for the type of processing. The emissions from ventilation or work process equipment should be checked to ensure compliance with the directives of the binding legislation on environmental protection.
NBR (nitrile rubber). 0,4-0,6 mm
Use close fitting safety goggles, don't use eye lens.
Mask with filter "A", brown colour
Chemical protection clothing.
Prevent spills into public sewers or the immediate environment. Do not empty into drains; dispose of this material and its container at a collection point for hazardous waste and in accordance with local regulations. Refer to applicable national and Community legislation concerning environmental protection, waste water, soil pollution and integrated pollution prevention and control (ex. IPPC). Check whether the activity that uses the product falls within the scope of Directive 96/61/EC (IPPC). The emissions from ventilation or work process equipment should be checked to ensure compliance with the directives of the binding legislation on environmental protection. In some cases, to reduce emissions, might be needed maintenance or technical plant modifications.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions
Stable under normal conditions
Stable under normal conditions.
Oxidising agents.
Formaldeide (aldeide formica). methanol
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1866
- Shipping Name
- RESIN SOLUTION
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ICAPLINK A520?
The signal word is danger.
What is the physical form of ICAPLINK A520?
ICAPLINK A520 is a liquid appearing as liquid colorless with colorless color. It has formaldehyde odor.
What is ICAPLINK A520 used for?
Industrial user (SU3) Cross Linking Agent.
What are the hazard statements for ICAPLINK A520?
This substance has 7 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H350: May cause cancer.
What is the melting point of ICAPLINK A520?
The melting point is N.A. and the boiling point is 108°C.