NextSDS Logo
Safety Data Sheet EN

2K-DC LACK DTM HYDRO RAL 5009

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
2K-DC LACK DTM HYDRO RAL 5009
Product Code
PD7952500900

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Dr. Demuth Derisol Lackfarben GmbH & Co. KG logo

Dr. Demuth Derisol Lackfarben GmbH & Co. KG

national supplier

Hillerser Str. 8, 37154 Northeim, Germany

+495551 97940

https://www.dr-demuth.com

Emergency Contacts

Emergency Contact

+49555197940

Only available during office hours.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
1-butoxypropan-2-ol EC: 225-878-4 5131-66-8 3 - 5% Yes
2,4,7,9-tetramethyldec-5-yne-4,7-diol EC: 204-809-1 126-86-3 0.1 - 0.15% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest. In case of irregular breathing or respiratory arrest provide artificial respiration.

Skin contact

Remove contaminated, saturated clothing immediately. After contact with skin, wash immediately with plenty of water and soap. Do not use solvents or thinners.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical advice immediately.

Ingestion

If swallowed, rinse mouth with water (only if the person is conscious). Seek medical advice immediately. Keep victim calm. Do NOT induce vomiting.

Medical Treatment

First Aid, decontamination, treatment of symptoms.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

alcohol resistant foam, Carbon dioxide (CO2), Powder, spray mist, (water)

Unsuitable media

Strong water jet

Specific hazards

Dense black smoke occurs during fire. Inhaling hazardous decomposing products can cause serious health damage.

Instructions

Cool closed containers that are near the source of the fire.

Firefighter Protection

Provide a conveniently located respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ventilate affected area. Do not breathe vapours.

Environmental

Do not allow to enter into surface water or drains.

Cleanup methods

Clean using cleansing agents. Do not use solvents.

Materials: cleansing agents

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin, eyes and clothes. Avoid respiration of swarf. Personal protection equipment: see section 8 Do not empty containers with pressure - no pressure vessel! Always keep in containers that correspond to the material of the original container. Follow the legal protection and safety regulations.

Storage

Storage in accordance with the Ordinance on Industrial Safety and Health (BetrSiVO). Keep container tightly closed. Do not empty containers with pressure - no pressure vessel! Smoking is forbidden. Access only for authorised persons. Store carefully closed containers upright to prevent any leaks.

Hygiene

When using do not eat, drink or smoke.

Fire prevention

Smoking is forbidden.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide good ventilation. This can be achieved with local or room suction.

Hands

For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Observe the instructions and details for use, storage, maintenance and replacement provided by the protective glove manufacturer. Penetration time of glove material depending on intensity and duration of exposure to skin. Recommended glove articles: EN ISO 374

Eyes

Eye glasses with side protection: EN 166

Respiratory

In case of inadequate ventilation wear respiratory protection.

Skin/Body

Barrier creams can help protecting exposed skin areas. In no case should they be used after contact. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn. Antistatic clothing including shoes are recommended.

Environmental

Do not allow to enter into surface water or drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
---
Properties Status
---
Softening Point
---
Kinematic Viscosity
> 700 mm²/s
Appearance
---
Relative Density
---
Explosive Limits
---
Colour Intensity
---
Density
1.4 kg/l
Voc Content
---
Physical State
Liquid
Odor
characteristic
Partition Coefficient
see section 12
Odor Threshold
---
Vapor Pressure
0.079 mbar
Molecular Weight
---
Boiling Point
> 35 °C
Dynamic Viscosity
---
Decomposition Temperature
---
Colour
red
Crystallisation Point
---
Solidification Point
---
Ph
8 - 9
Solubility In Fat
---
State Under Standard Conditions
---
Auto Ignition Temperature
260 °C
Flash Point
not determined
Flammability
not applicable
Lower Explosive Limit
not determined
Evaporation Rate
---
Solubility In Water
partially soluble
Physical State Data
liquid
Melting Point
< -85 °C
Relative Evaporation Rate
---
Cloud Point
---
Solubility
---
Metal Corrosion
---
Bulk Density
---
Freezing Point
---
Upper Explosive Limit
not determined
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable when applying the recommended regulations for storage and handling. Further information on correct storage: refer to section 7.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Keep away from strong acids, strong bases and strong oxidizing agents to avoid exothermic reactions.

Avoid

High temperatures.

Decomposition

Carbon dioxide (CO2), Carbon monoxide, smoke.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 2K-DC LACK DTM HYDRO RAL 5009?

The signal word is no signal word.

What is the physical form of 2K-DC LACK DTM HYDRO RAL 5009?

2K-DC LACK DTM HYDRO RAL 5009 is a liquid with red color. It has characteristic odor.

What is the melting point of 2K-DC LACK DTM HYDRO RAL 5009?

The melting point is < -85 °C and the boiling point is > 35 °C.