NextSDS Logo
Safety Data Sheet EN

RIDGID Dark Thread Cutting Oil (United States)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RIDGID Dark Thread Cutting Oil (United States)
Product Code
11471, 11491, 41590, 41600, 41610, 70830

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Thread Cutting

Uses advised against

Industrial use only

Manufacturers & Suppliers

Ridge Tool Company logo

Ridge Tool Company

manufacturer

400 Clark Street, Elyria, Ohio 44035-6001

1-800-519-3456

http://www.RIDGID.com

Ridge Tool Australia logo

Ridge Tool Australia

distributor

127 Metrolink Circuit, Campbellfield, VIC 3061

1-800-743-443

http://www.RIDGID.com.au

Emergency Contacts

Emergency Contact

9-1-1

Emergency Contact

000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

Not applicable

Precautionary Statements

Not applicable

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This product does not contain silicone or chlorinated additives.

Chemical Name CAS Number Concentration Hazardous
Mineral oil --- 20 - 50% Yes
Paraffin oils --- 20 - 50% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Call a POISON CENTER/doctor if you feel unwell.

Skin contact

Remove contaminated clothing and shoes. Wash contact areas with soap and water. If skin irritation occurs: Get medical advice/attention.

Eye contact

Flush thoroughly with water. If irritation occurs, get medical assistance. Continue to rinse for at least 15 minutes.

Ingestion

Rinse mouth thoroughly. Call a POISON CENTER/doctor if you feel unwell. Do NOT induce vomiting.

Immediate Medical Attention

Get medical attention if symptoms occur.

Medical Treatment

Get medical attention if symptoms occur.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, fog, CO2, dry chemical, or regular foam. Use fire-extinguishing media appropriate for surrounding materials.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

Heat may cause the containers to explode. During fire, gases hazardous to health may be formed.

Instructions

No data available.

Firefighter Protection

Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep unauthorized personnel away.

Environmental

Avoid release to the environment.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

End-users should follow industry best practices for handling and using this product. Guidance may be found using the current version of ASTM Standard E1497-05: Standard Practice for Selection and Safe Use of Water-Miscible and Straight Oil Metal Removal Fluids Observe good industrial hygiene practices. Wear appropriate personal protective equipment. Do not expose to intense heat as product may expand and pressurize container.

Storage

Store in original tightly closed container. Avoid contact with oxidizing agents. Store away from incompatible materials.

Hygiene

Observe good industrial hygiene practices.

Fire prevention

Do not expose to intense heat as product may expand and pressurize container.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

In case of inadequate ventilation use suitable respirator. Seek advice from supervisor on the company's respiratory protection standards.

Skin/Body

Wear protective clothing appropriate for the risk of exposure. Be aware of other hazards such as rotating parts. Contact health and safety professional or manufacturer for specific information.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
---
Colour Intensity
---
Relative Evaporation Rate
---
Molecular Weight
---
Cloud Point
---
Auto Ignition Temperature
---
Relative Density
0.878
Upper Explosive Limit
---
Solubility In Water
Insoluble
Vapor Density
---
Bulk Density
---
Form
---
Solubility
---
Density
---
Flammability
---
Melting Point
---
Freezing Point
---
Dynamic Viscosity
---
Properties Status
---
Vapor Pressure
---
Ph
---
Voc Content
1.99 g/l (ASTM E 1868-10)
Explosive Limits
---
Odor
Mild petroleum/solvent
Flash Point
196.11 °C (385.00 °F)
Kinematic Viscosity
42.5 mm2/s (40 °C, Measured)
Physical State
Liquid
Metal Corrosion
---
Physical State Data
liquid
Evaporation Rate
---
Solidification Point
---
Partition Coefficient
---
Decomposition Temperature
---
Colour
Black
Boiling Point
---
Odor Threshold
---
Solubility In Fat
---
Appearance
---
State Under Standard Conditions
---
Softening Point
---
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

Not reactive during normal use.

Hazardous reactions

None under normal conditions.

Avoid

Avoid heat or contamination.

Incompatible

No data available.

Decomposition

Thermal decomposition or combustion may liberate carbon oxides and other toxic gases or vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RIDGID Dark Thread Cutting Oil (United States)?

The signal word is no signal word.

What is the physical form of RIDGID Dark Thread Cutting Oil (United States)?

RIDGID Dark Thread Cutting Oil (United States) is a liquid with black color. It has mild petroleum/solvent odor.

What is RIDGID Dark Thread Cutting Oil (United States) used for?

Thread Cutting

What are the hazard statements for RIDGID Dark Thread Cutting Oil (United States)?

This substance has 1 hazard statement:

  • Not applicable