NextSDS Logo
Safety Data Sheet EN

Pierce IP Lysis Buffer

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Pierce IP Lysis Buffer
Product Code
87787
Chemical Name
Not Applicable

Regulatory Identifiers

CAS Number
N/A
REACH No.
No registration number is given yet for this substance / substances in this mixture since the annual import quantity is less than one tonnage per annum or the transition period for its registration according to Article 23 of REACH has not yet expired.
UFI Code
Not Applicable

Identified Uses

For research use only. SU22 - Professional uses: Public domain (administration, education, entertainment, services, craftsmen), PROC15 - Use as laboratory reagent, PC21 - Laboratory chemicals, SU24 - Scientific research and development

Uses advised against

Not for consumer use.

Manufacturers & Suppliers

L

LIFE TECHNOLOGIES EUROPE BV

manufacturer

KWARTSWEG 2, 2665 NN BLEISWIJK, NETHERLANDS

31-(0)180 392 400

P

Pierce Biotechnology

manufacturer

P.O. Box 117, Rockford, IL 61105, United States

1.815.968.0747

L

Life Technologies Limited

manufacturer

3 Fountain Drive, Inchinnan Business Park, Paisley PA4 9RF, UK

+44 (0)141 814 6100

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

CHEMTREC

1-703-741-5970

CHEMTREC Ireland (Dublin)

+(353)-19014670

EN

CHEMTREC UK (London)

+(44)-870-8200418

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Carc. Cat. 2

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H351 Suspected of causing cancer

Precautionary Statements

P201 Obtain special instructions before use
P202 Do not handle until all safety precautions have been read and understood
P280 Wear protective gloves/protective clothing/eye protection/face protection
P308 + P313 IF exposed or concerned: Get medical advice/attention
P501 Dispose of contents/ container to an approved waste disposal plant

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Poly(oxy-1,2-ethanediyl), .alpha.-(nonylphenyl)-.omega.-hydroxy- EC: 500-024-6 9016-45-9 0.1 - 1% Yes
Methylene chloride EC: 200-838-9 75-09-2 3 - 7% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If symptoms persist, call a doctor.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Never give anything by mouth to an unconscious person. Do not induce vomiting without medical advice. Get medical attention if symptoms occur.

Immediate Medical Attention

IF exposed or concerned: Get medical advice/attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Carbon dioxide (CO2). Foam. Dry chemical.

Unsuitable media

No information available.

Specific hazards

Not known

Instructions

Standard procedure for chemical fires.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Prevent product from entering drains. Do not allow material to contaminate ground water system.

Cleanup methods

Soak up with inert absorbent material.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use personal protective equipment as required. Do not get in eyes, on skin, or on clothing. Always wear recommended Personal Protective Equipment. See section 8 for more information.

Storage

Keep in a dry, cool and well-ventilated place. Keep in properly labelled containers.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feedingstuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
No data
Colour Intensity
---
Form
---
Odor
No data
Odor Threshold
---
Ph
---
Melting Point
No data
Boiling Point
No data
Flash Point
No data
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data
Vapor Pressure
No data
Vapor Density
No data
Relative Density
No data
Bulk Density
---
Density
---
Flammability
No data
Upper Explosive Limit
No data
Lower Explosive Limit
No data
Explosive Limits
---
Auto Ignition Temperature
No data
Decomposition Temperature
No data
Solubility
No data
Partition Coefficient
No data
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
No data
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data
Kinematic Viscosity
No data
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known.

Hazardous reactions

Hazardous reaction has not been reported.

Avoid

No information available.

Incompatible

No dangerous reaction known under conditions of normal use.

Decomposition

None under normal use conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Pierce IP Lysis Buffer?

The signal word is warning.

What is the physical form of Pierce IP Lysis Buffer?

Pierce IP Lysis Buffer is a liquid with no data color. It has no data odor.

What is the solubility of Pierce IP Lysis Buffer?

No data

What is Pierce IP Lysis Buffer used for?

For research use only. SU22 - Professional uses: Public domain (administration, education, entertainment, services, craftsmen), PROC15 - Use as laboratory reagent, PC21 - Laboratory chemicals, SU24 - Scientific research and development

What are the hazard statements for Pierce IP Lysis Buffer?

This substance has 1 hazard statement:

  • H351: Suspected of causing cancer

What is the melting point of Pierce IP Lysis Buffer?

The melting point is No data and the boiling point is No data.