Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Succinic acid for analysis EMSURE® ACS
- Product Code
- 1.00682
- Chemical Name
- Succinic acid
Regulatory Identifiers
- CAS Number
- 110-15-6 Check regulations →
- REACH No.
- 01-2119896114-34-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5, D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| succinic acid EC: 203-740-4 | 110-15-6 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Immediate Medical Attention
Immediately call in ophthalmologist. Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides. Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Citric acid monohydrate for analysis EMSURE® ACS, ISO, Reag. Ph Eur
CAS: 5949-29-1
Sulfuric acid 98% for analysis EMSURE®
CAS: 7664-93-9
Dimethyl sulfoxide for analysis EMSURE® ACS
CAS: 67-68-5
Sulfuric acid 25% for analysis EMSURE®
---
Nitric acid 69% for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 7697-37-2
Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 631-61-8
Ethyl acetate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 141-78-6
Sodium acetate trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 6131-90-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Dry.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
Violent reactions possible with: strong oxidising agents, bases
no information available
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Succinic acid for analysis EMSURE® ACS?
The signal word is danger.
What is the physical form of Succinic acid for analysis EMSURE® ACS?
Succinic acid for analysis EMSURE® ACS is a solid with white color. It has odorless odor.
What is Succinic acid for analysis EMSURE® ACS used for?
Reagent for analysis
What are the hazard statements for Succinic acid for analysis EMSURE® ACS?
This substance has 1 hazard statement:
- H318: Causes serious eye damage.
What is the melting point of Succinic acid for analysis EMSURE® ACS?
The melting point is Melting point: 188 °C and the boiling point is 235 °C at 1.013 hPa.