NextSDS Logo
Safety Data Sheet EN

Succinic acid for analysis EMSURE® ACS

CAS 110-15-6

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Succinic acid for analysis EMSURE® ACS
Product Code
1.00682
Chemical Name
Succinic acid

Regulatory Identifiers

CAS Number
110-15-6 Check regulations →
REACH No.
01-2119896114-34-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H318 Causes serious eye damage.

Precautionary Statements

P280 Wear eye protection/ face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
succinic acid EC: 203-740-4 110-15-6 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

Immediate Medical Attention

Immediately call in ophthalmologist. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides. Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
2,7 at 10 g/l at 20 °C
Properties Status
---
Flash Point
Not applicable
Colour Intensity
---
Colour
white
Physical State Data
solid
Flammability
No data available
Physical State
solid
Explosive Limits
---
Freezing Point
---
Kinematic Viscosity
No data available
Boiling Point
235 °C at 1.013 hPa
Softening Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Solubility In Fat
---
Odor Threshold
---
Partition Coefficient
No data available
Metal Corrosion
---
Density
1,57 g/cm3 at 25 °C
Decomposition Temperature
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
State Under Standard Conditions
---
Solubility
---
Dynamic Viscosity
No data available
Evaporation Rate
---
Upper Explosive Limit
No data available
Cloud Point
---
Melting Point
Melting point: 188 °C
Auto Ignition Temperature
> 220 °C - Relative self-ignition temperature for solids does not ignite
Lower Explosive Limit
No data available
Appearance
---
Solubility In Water
83 g/l at 25 °C - completely soluble
Molecular Weight
---
Form
---
Odor
odorless
Voc Content
---
Bulk Density
940 kg/m3
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Violent reactions possible with: strong oxidising agents, bases

Avoid

no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Succinic acid for analysis EMSURE® ACS?

The signal word is danger.

What is the physical form of Succinic acid for analysis EMSURE® ACS?

Succinic acid for analysis EMSURE® ACS is a solid with white color. It has odorless odor.

What is Succinic acid for analysis EMSURE® ACS used for?

Reagent for analysis

What are the hazard statements for Succinic acid for analysis EMSURE® ACS?

This substance has 1 hazard statement:

  • H318: Causes serious eye damage.

What is the melting point of Succinic acid for analysis EMSURE® ACS?