Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dimethyl sulfoxide for analysis EMSURE® ACS
- Product Code
- 1.02952
- Chemical Name
- Dimethyl sulfoxide
Regulatory Identifiers
- CAS Number
- 67-68-5 Check regulations →
- REACH No.
- 01-2119431362-50-XXXX
Identified Uses
Reagent for analysis, Chemical production
Manufacturers & Suppliers
Millipore
manufacturer
http://www.sigmaaldrich.com
Supelco
manufacturer
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5, D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Formula : C2H6OS Molecular weight : 78,13 g/mol CAS-No. : 67-68-5 EC-No. : 200-664-3
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| C2H6OS EC: 200-664-3 | 67-68-5 | --- | No |
Notes
No components need to be disclosed according to the applicable regulations.
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
rinse out with plenty of water. Remove contact lenses.
make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating.
Remove container from danger zone and cool with water. Suppress (knock down) gases/vapors/mists with a water spray jet.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
tert-Butanol for analysis EMSURE® ACS
CAS: 75-65-0
di-Sodium oxalate for analysis EMSURE®
CAS: 62-76-0
Sulfuric acid 98% for analysis EMSURE®
CAS: 7664-93-9
Sulfuric acid 25% for analysis EMSURE®
---
Succinic acid for analysis EMSURE® ACS
CAS: 110-15-6
Chloroform for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-66-3
Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 78-83-1
Ethyl acetate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 141-78-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.
Tightly closed.
Change contaminated clothing. Wash hands after working with substance.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Chloroprene, Minimum layer thickness: 0,65 mm, Break through time: 480 min, Material tested: KCL 720 Camapren®. Splash contact: Material: Latex gloves, Minimum layer thickness: 0,6 mm, Break through time: 240 min, Material tested: Lapren® (KCL 706 / Aldrich Z677558, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
Risk of explosion with: acetylcholine, organic halides, perchlorates, Acid chlorides, nonmetallic halides, iron(III) compounds, nitrates, fluorides, chlorates, hydrides, perchloric acid, Oxides of phosphorus, Nitric acid, silver compounds, silicon compounds, silanes, acid halides. Exothermic reaction with: boron compounds, oxyhalogenic compounds, Potassium, sodium, Strong oxidizing agents, phosphorus halides, strong reducing agents, Acid chlorides, Strong acids. Risk of ignition or formation of inflammable gases or vapours with: potassium permanganate.
Strong heating.
acetylcholine, organic halides, perchlorates, Acid chlorides, nonmetallic halides, iron(III) compounds, nitrates, fluorides, chlorates, hydrides, perchloric acid, Oxides of phosphorus, Nitric acid, silver compounds, silicon compounds, silanes, acid halides, boron compounds, oxyhalogenic compounds, Potassium, sodium, Strong oxidizing agents, phosphorus halides, strong reducing agents, Strong acids, potassium permanganate.
silver salt, nitrogen dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dimethyl sulfoxide for analysis EMSURE® ACS?
The signal word is no signal word.
What is the physical form of Dimethyl sulfoxide for analysis EMSURE® ACS?
Dimethyl sulfoxide for analysis EMSURE® ACS is a liquid with colorless color. It has odorless odor.
What is Dimethyl sulfoxide for analysis EMSURE® ACS used for?
Reagent for analysis, Chemical production
What is the melting point of Dimethyl sulfoxide for analysis EMSURE® ACS?
The melting point is 18,5 °C and the boiling point is 189 °C at 1.013 hPa.