Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Potassium hydrogen phthalate for analysis EMSURE® Reag. Ph Eur
- Product Code
- 1.04874
Regulatory Identifiers
- CAS Number
- 877-24-7 Check regulations →
- REACH No.
- 01-2120212164-72-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5, D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Formula : C8H5O4K Molecular weight : 204,22 g/mol CAS-No. : 877-24-7 EC-No. : 212-889-4
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| C8H5O4K EC: 212-889-4 | 877-24-7 | --- | No |
Notes
No components need to be disclosed according to the applicable regulations.
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water Foam Carbon dioxide (CO2) Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides, Potassium oxides. Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Potassium hydrogen phthalate for analysis EMSURE® Reag. Ph Eur
CAS: 877-24-7
Potassium dihydrogen phosphate for analysis EMSURE® ISO
CAS: 7778-77-0
Potassium dichromate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7778-50-9
Potassium sulfate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7778-80-5
Potassium nitrate for analysis EMSURE® ISO,Reag. Ph Eur
CAS: 7757-79-1
Potassium nitrate for analysis EMSURE® ISO,Reag. Ph Eur
CAS: 7757-79-1
di-Potassium hydrogen phosphate anhydrous for analysis EMSURE®
CAS: 7758-11-4
Potassium iodide for analysis EMSURE® ISO, Reag. Ph Eur
CAS: 7681-11-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Dry. Recommended storage temperature see product label.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P1. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical. The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
Violent reactions possible with: Strong oxidizing agents, Nitric acid
Strong heating.
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Potassium hydrogen phthalate for analysis EMSURE® Reag. Ph Eur?
The signal word is no signal word.
What is the physical form of Potassium hydrogen phthalate for analysis EMSURE® Reag. Ph Eur?
Potassium hydrogen phthalate for analysis EMSURE® Reag. Ph Eur is a solid with colorless color. It has no data available odor.
What is Potassium hydrogen phthalate for analysis EMSURE® Reag. Ph Eur used for?
Reagent for analysis
What is the melting point of Potassium hydrogen phthalate for analysis EMSURE® Reag. Ph Eur?
The melting point is 301,7 - 303,7 °C at 974,9 hPa and the boiling point is > 300 °C at 977,5 hPa.