Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Potassium dihydrogen phosphate for analysis EMSURE® ISO
Product Code
1.04873
Chemical Name
Potassium dihydrogen phosphate

Regulatory Identifiers

CAS Number
7778-77-0 Check regulations →
REACH No.
01-2119490224-41-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
EC-No. : 231-913-4 EC: 231-913-4 --- --- No

Notes

Remarks : No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material : Nitrile rubber Break through time : 480 min Glove thickness : 0,11 mm Protective index : Full contact Manufacturer : KCL 741 Dermatril® L Material : Nitrile rubber Break through time : 480 min Glove thickness : 0,11 mm Protective index : Splash contact Manufacturer : KCL 741 Dermatril® L Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter type P1 type: The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
crystalline
Appearance
---
Physical State Data
solid
Bulk Density
ca. 1.200 kg/m3
Colour Intensity
---
Flammability
The product is not flammable.
Kinematic Viscosity
No data available
Cloud Point
---
Upper Explosive Limit
Not applicable
Odor Threshold
Not applicable
Ph
4,2 - 4,6 (20,0 °C)
Softening Point
---
Relative Evaporation Rate
---
Odor
odourless
Solubility In Water
208 g/l (20 °C)
Lower Explosive Limit
Not applicable
Relative Density
2,33 (21,5 °C)
Melting Point
252,6 °C
Flash Point
Not applicable
Explosive Limits
---
Colour
colourless
Solidification Point
---
Evaporation Rate
No data available
Partition Coefficient
Not applicable for inorganic substances
Properties Status
---
Metal Corrosion
---
Solubility
---
Vapor Density
---
State Under Standard Conditions
---
Dynamic Viscosity
No data available
Solubility In Fat
---
Voc Content
---
Auto Ignition Temperature
not combustible
Density
2,34 g/cm3
Decomposition Temperature
No data available
Molecular Weight
136,09 g/mol
Freezing Point
---
Crystallisation Point
---
Boiling Point
450 °C (1.013 hPa)
Physical State
solid
Vapor Pressure
< 0,1 hPa (25 °C)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents, Bases, acids

Avoid

Strong heating (decomposition).

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Potassium dihydrogen phosphate for analysis EMSURE® ISO?

The signal word is no signal word.

What is the physical form of Potassium dihydrogen phosphate for analysis EMSURE® ISO?

Potassium dihydrogen phosphate for analysis EMSURE® ISO is a solid with colourless color. It has odourless odor.

What is Potassium dihydrogen phosphate for analysis EMSURE® ISO used for?

Reagent for analysis

What is the melting point of Potassium dihydrogen phosphate for analysis EMSURE® ISO?

The melting point is 252,6 °C and the boiling point is 450 °C (1.013 hPa).