NextSDS Logo
Safety Data Sheet EN

di-Potassium hydrogen phosphate trihydrate for analysis EMSURE®

CAS 16788-57-1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
di-Potassium hydrogen phosphate trihydrate for analysis EMSURE®
Product Code
105099

Regulatory Identifiers

CAS Number
16788-57-1 Check regulations →
REACH No.
01-2119493919-15-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
di-Potassium hydrogen phosphate trihydrate for analysis EMSURE® EC: 231-834-5 --- --- No

For the full text of the H-Statements mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Safety glasses

Respiratory

required when dusts are generated. Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Properties Status
---
Ph
9,2 - 9,4 at 50 g/l 20 °C
Density
No information available.
Form
solid
Partition Coefficient
log Pow: -5,8 (calculated) (anhydrous substance) Bioaccumulation is not expected.
Vapor Pressure
No information available.
Relative Evaporation Rate
---
Vapor Density
---
Colour
white
Decomposition Temperature
ca.180 °C
Flash Point
Not applicable
Lower Explosive Limit
Not applicable
Upper Explosive Limit
Not applicable
State Under Standard Conditions
---
Molecular Weight
---
Odor Threshold
Not applicable
Voc Content
---
Metal Corrosion
---
Explosive Limits
---
Cloud Point
---
Crystallisation Point
---
Appearance
---
Solubility In Water
at 20 °C soluble
Odor
odourless
Colour Intensity
---
Auto Ignition Temperature
No information available.
Physical State Data
solid
Softening Point
---
Melting Point
ca. 340 °C (anhydrous substance), decomposes
Physical State
solid
Bulk Density
ca.800 kg/m³
Solubility
---
Dynamic Viscosity
No information available.
Solubility In Fat
---
Flammability
The product is not flammable.
Relative Density
No information available.
Boiling Point
No information available.
Freezing Point
---
Kinematic Viscosity
---
Evaporation Rate
No information available.
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

See section 10.3

Hazardous reactions

no information available

Avoid

no information available

Incompatible

no information available

Decomposition

in the event of fire: See section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for di-Potassium hydrogen phosphate trihydrate for analysis EMSURE®?

The signal word is no signal word.

What is the physical form of di-Potassium hydrogen phosphate trihydrate for analysis EMSURE®?

di-Potassium hydrogen phosphate trihydrate for analysis EMSURE® is a solid with white color. It has odourless odor.

What is di-Potassium hydrogen phosphate trihydrate for analysis EMSURE® used for?

Reagent for analysis

What is the melting point of di-Potassium hydrogen phosphate trihydrate for analysis EMSURE®?

The melting point is ca. 340 °C (anhydrous substance), decomposes and the boiling point is No information available..