NextSDS Logo
Safety Data Sheet EN

NucleoSpin Plant II (50)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NucleoSpin Plant II (50)
Product Code
740770.50

Regulatory Identifiers

CAS Number
N/A
REACH No.
see SECTION 3.1/3.2 or A registration number for the substance(s) does not exist because the annual tonnage does not require registration or the substance or its use is excluded from registration.
UFI Code
60EV-03C8-D201-X08S, MMPT-631A-V206-GNTN, WWJV-U3PV-U207-MFGF

Identified Uses

Product for analytical use. Exposure Scenario Classification according REACH, RIP 3.2 Codes: SU 0-2, PC 21, PROC 15, AC 0 The exposure scenario is integrated into sections 1-16.

Uses advised against

not described

Manufacturers & Suppliers

M

MACHEREY-NAGEL GmbH & Co. KG

manufacturer

Valenciennen Str. 11, 52355 Duren, Germany

+49 2421 969 0

Emergency Contacts

Gemeinsames Giftinformationszentrum (GGIZ)

+49 361 730 730

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Acute Tox. Cat. 4 H302
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Flam. Liq. Cat. 3 H226
Acute Tox. Cat. 4 H302
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H336
Resp. Sens. Cat. 1 H334

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.

Precautionary Statements

P261 Avoid breathing dust/vapours
P284 [In case of inadequate ventilation] wear respiratory protection.
P501 Dispose of contents/container to regulated waste treatment.
If experiencing respiratory symptoms: Call a POISON CENTER/doctor.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
dodecyl sulfate, sodium salt EC: 205-788-1 151-21-3 1 - 2.5% Yes
sodium chloride EC: 231-598-3 7647-14-5 1 - 10% No
guanidine hydrochloride EC: 200-002-3 50-01-1 24 - 50% Yes
ethanol EC: 200-578-6 64-17-5 35 - 55% Yes
2-propanol EC: 200-661-7 67-63-0 20 - 35% Yes
RNase EC: 232-646-6 9001-99-4 90 - 100% Yes
acetate buffer solution --- 45 - 60% No

When not listed, mixtures are added with water [CAS No. 7732-18-5] to 100%.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation of foam or vapour fresh air should be inhaled. Keep airways free. Administer a Dexamethasone spray as soon as possible. Ensure quiet, warmth, and provide resuscitation if necessary. In the event of respiratory distress ensure that the patient inhales oxygen. Secure the breathing, heart and circulatory function.

Symptoms: May cause allergy or asthma symptoms or breathing difficulties if inhaled.

Skin contact

Remove contaminated clothing. Rinse the affected skin or mucous membrane thoroughly under running water. (If possible) use soap.

Eye contact

After contact with the eyes rinse thoroughly under running water with the eyelid wide open with eye washing bottle, eye douche or running water (protect intact eye).

Ingestion

After oral intake lots of water should be drunk after it has been ingested.

Medical Treatment

Inform patient respectively further measures and the possibility of long-term damages.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Fire extinguishers appropriate to the fire classification, and, if applicable, a fire blanket must be available in a prominent location in the work area. All extinguishers like FOAM, WATER SPRAY, DRY POWDER, CARBON DIOXIDE can be used.

Unsuitable media

no data available

Specific hazards

Flammable (GHS regulation). May form explosive vapour-air mixtures. Formation of hazardous and caustic vapour-air mixtures possible.

Instructions

No, for listed product.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapours. Regular staff training is necessary, indicating hazards and precautions on the basis of operating instructions. Restrictions on activity must be observed.

Small spill

Collect small amounts of leaked liquid and flush with water into drains.

Environmental

PBT: not applicable, vPvB: not applicable

Cleanup methods

Clean any contaminated equipment and floors with plenty of water. Collect small amounts of leaked liquid and flush with water into drains.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handling in accordance with the test instruction, that comes with the product.

Storage

Safe storage is guaranteed in the original packaging from MACHEREY-NAGEL. Keep original product packages tightly closed during handling and storage.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good ventilation and extraction system in the room, floor resistant to chemicals with floor drainage and washing facilities.

Hands

Yes, gloves according EN 374 (permeation time >30 min - level 2), consist of PVC, natural latex, Neopren, or Nitril (f.ex. from Ansell or KCL). Use for short times chemical resistant latex gloves with code EN 374-3 level 1.

Eyes

Yes, safety glasses according EN 166 with integrated side shields or wrap-around protection.

Respiratory

Use for open access of these substances for example a protection filter, class A/AX. No additional recommendations.

Skin/Body

Recommended to avoid contamination with these hazards.

Environmental

Do not release product into environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Softening Point
---
Bulk Density
---
Explosive Limits
---
Lower Explosive Limit
---
Metal Corrosion
---
Relative Evaporation Rate
---
Physical State Data
liquid
Melting Point
no data available
Freezing Point
---
Form
---
Partition Coefficient
---
Physical State
liquid
Solidification Point
---
Dynamic Viscosity
---
Evaporation Rate
---
Odor Threshold
---
Appearance
---
Auto Ignition Temperature
---
Colour
yellow
Cloud Point
---
Vapor Density
---
Vapor Pressure
---
Solubility In Fat
---
Odor
alcoholic
Decomposition Temperature
---
Flash Point
23 °C
Relative Density
1.01 g/cm³
Crystallisation Point
---
State Under Standard Conditions
---
Voc Content
---
Properties Status
---
Kinematic Viscosity
---
Solubility
---
Boiling Point
no data available
Molecular Weight
---
Colour Intensity
---
Ph
5-7
Density
1.01 g/cm³
Solubility In Water
---
Flammability
---
Upper Explosive Limit
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

no known instability.

Reactivity

no further data available.

Hazardous reactions

Can form very reactive substances with oxidizing agents. No further data available.

Avoid

No more required.

Incompatible

no additional data available

Decomposition

Decompositions are not observed during the expiration period under recommended conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1993
Shipping Name
Flammable liquid, n.o.s. (2-propanol, ethanol mixture)
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NucleoSpin Plant II (50)?

The signal word is danger.

What is the physical form of NucleoSpin Plant II (50)?

NucleoSpin Plant II (50) is a liquid with yellow color. It has alcoholic odor.

What is NucleoSpin Plant II (50) used for?

Product for analytical use. Exposure Scenario Classification according REACH, RIP 3.2 Codes: SU 0-2, PC 21, PROC 15, AC 0 The exposure scenario is integrated into sections 1-16.

What are the hazard statements for NucleoSpin Plant II (50)?

This substance has 1 hazard statement:

  • H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.

What is the melting point of NucleoSpin Plant II (50)?

The melting point is no data available and the boiling point is no data available.