NextSDS Logo
Nu

NucleoSpin Gel and PCR Clean-up (50)

DANGER liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
NucleoSpin Gel and PCR Clean-up (50)
Product Code
740609.50

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
N5XV-533V-Y202-95TW

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Product for analytical use.
Uses Advised Against
not described

Overview

NucleoSpin Gel and PCR Clean-up (50) commonly used product for analytical use..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (DANGER)

Hazard Classifications

Acute Tox. Category 4 H302
Skin Corr. Category 1B H314
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H314: Causes severe skin burns and eye damage.

Precautionary Statements

  • P260: Do not breathe dust/vapours.
  • P264: Wash hands thoroughly after handling.
  • P280: Wear protective gloves/eye protection.
  • P310: Immediately call a POISON CENTER/doctor.
  • P405: Store locked up.
  • P501: Dispose of contents/container to regulated waste treatment.
  • IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

MACHEREY-NAGEL GmbH & Co. KG company logo - Safety Data Sheet supplier organization

MACHEREY-NAGEL GmbH & Co. KG

manufacturer

Valencienner Str. 11, 52355 Dren, Germany

DE

+49 2421 969 0

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Gemeinsames Giftinformationszentrum (GGIZ)

+49 361 730 730

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

When not listed, mixtures are added with water [CAS No. 7732-18-5] to 100%.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Guanidine Thiocyanate
EC: 209-812-1
593-84-0 30-45% Hazardous
indicator dye(s) N/A 0.1% Non-hazardous
chemicals/mixture until 1% N/A 0.1-1% Non-hazardous
chemicals/mixture until 1% N/A 0.1-1% Non-hazardous

Composition Notes

List of H and P phrases: see section 16.2.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

After inhalation of foam or vapour fresh air should be inhaled. Keep airways free. If vomiting and if insensible place patient in recovery position and keep airways free.

Skin Contact

Remove contaminated clothing immediately. Rinse the affected skin or mucous membrane thoroughly for min. 15 minutes under running water. (If possible) use soap. Avoid neutralisation. Then apply a loose bandage.

Symptoms:

Rapid penetration and destruction of the skin. Especially in the heated form. Causes severe skin burns and eye damage.

Eye Contact

After contact with the eyes rinse thoroughly under running water with the eyelid wide open for min. 10 minutes with eye washing bottle, eye douche or running water (protect intact eye). Before (if possible) apply eye drops Proxymetacaine 0.5%, if the opening the eyelid convulsion is painful. Further treatment to be carried out by an eye specialist.

Symptoms:

Causes severe skin burns and eye damage.

Ingestion/Swallowing

After oral intake lots of water with activated charcoal supplement should be drunk after it has been ingested. Do not induce vomiting under any circumstances. Do not make any efforts to neutralise it. Contact medical advice for possible consequences.

Immediate Medical Attention Required

If necessary contact medical advice. Further treatment to be carried out by an eye specialist. In the event of RESPIRATORY DISTREES ensure that the patient inhales oxygen.

Medical Treatment

Apply glucocorticosteroids following inflammatory reactions. Administer aluminium oxide drug suspensions after intake. Administer a prophylaxis to counter pulmonary oedema following the INGESTION of corrosive aerosols. In the event of RESPIRATORY DISTREES ensure that the patient inhales oxygen. Further treatment must be carried out by an eye specialist. Eyelid convulsion measures.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solubility In Water
no data available
Solubility In Fat
Not available
Physical State Data
liquid
Physical State
liquid
Critical Property
Evaporation Rate
Not available
Density
1.12 g/cm
Critical Property
Solidification Point
Not available
Flammability
no data available
Bulk Density
Not available
Vapor Density
Not available
Dynamic Viscosity
Not available
Odor
acetic
Boiling Point
no data available
Critical Property
Lower Explosive Limit
no data available
Colour
blue
Form
Not available
Softening Point
Not available
Auto Ignition Temperature
Not available
Relative Evaporation Rate
Not available
Decomposition Temperature
no data available
Relative Density
1.12 g/cm
Kinematic Viscosity
no data available
State Under Standard Conditions
Not available
Properties Status
Not available
Metal Corrosion
Substances are highly corrosive.
Vapor Pressure
no data available
Explosive Limits
Not available
Colour Intensity
Not available
Melting Point
no data available
Critical Property
Cloud Point
Not available
Solubility
Not available
Partition Coefficient
no data available
Ph
4.5-5.5
Upper Explosive Limit
no data available
Freezing Point
Not available
Flash Point
no data available
Critical Property
Appearance
Not available
Molecular Weight
Not available
Voc Content
Not available
Crystallisation Point
Not available
Odor Threshold
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Good ventilation and extraction system in the room, floor resistant to chemicals with floor drainage and washing facilities.

Hand Protection

Yes, gloves according EN 374 (permeation time >30 min - level 2), consist of PVC, natural latex, Neopren, or Nitril (f.ex. from Ansell or KCL). Use for short times chemical resistant latex gloves with code EN 374-3 level 1.

Eye Protection

Yes, safety glasses according EN 166 with integrated side shields or wrap-around protection or face protection.

Respiratory Protection

No additional recommendations.

Skin/Body Protection

Recommended to avoid clothing damage, and to avoid contamination with these hazards.

Environmental Exposure Controls

Do not release product into environment.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

3316

Proper Shipping Name

Chemical kit

Transport Hazard Class

9

Packing Group

II

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for NucleoSpin Gel and PCR Clean-up (50)?

The signal word for this substance is "danger".

What is the physical form of NucleoSpin Gel and PCR Clean-up (50)?

NucleoSpin Gel and PCR Clean-up (50) is a liquid with blue color. It has acetic odor.

What is NucleoSpin Gel and PCR Clean-up (50) used for?

Product for analytical use.

What are the hazard statements for NucleoSpin Gel and PCR Clean-up (50)?

This substance has 1 hazard statements: H314: Causes severe skin burns and eye damage.

What is the melting point of NucleoSpin Gel and PCR Clean-up (50)?

The melting point is no data available and the boiling point is no data available.