Basic Product Information

Product Name
NucleoSpin Gel and PCR Clean-up (50)
Product Code
REF 740609.50

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
N5XV-533V-Y202-95TW

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Product for analytical use.
Uses Advised Against
not described

Overview

NucleoSpin Gel and PCR Clean-up (50) commonly used product for analytical use..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (DANGER)

Hazard Classifications

Acute Tox. Category 4 H302
Skin Corr. Category 1B H314
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H314: Causes severe skin burns and eye damage.

Precautionary Statements

  • P260: Do not breathe dust/vapours.
  • P264: Wash hands thoroughly after handling.
  • P280: Wear protective gloves/eye protection.
  • P310: Immediately call a POISON CENTER/doctor.
  • P405: Store locked up.
  • P501: Dispose of contents/container to regulated waste treatment.
  • IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

MACHEREY-NAGEL GmbH & Co. KG company logo - Safety Data Sheet supplier organization

MACHEREY-NAGEL GmbH & Co. KG

manufacturer

๐Ÿ“

Valencienner Str. 11, 52355 Dren, Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 2421 969 0

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Gemeinsames Giftinformationszentrum (GGIZ)

๐Ÿ“ž

+49 361 730 730

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

When not listed, mixtures are added with water [CAS No. 7732-18-5] to 100%.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Guanidinium thiocyanaat
EC: 209-812-1
593-84-0 30-45% โš ๏ธ Hazardous
indicator dye(s) N/A 0.1% โœ“ Non-hazardous
chemicals/mixture until 1% N/A 0.1-1% โœ“ Non-hazardous
chemicals/mixture until 1% N/A 0.1-1% โœ“ Non-hazardous

Composition Notes

List of H and P phrases: see section 16.2.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

After inhalation of foam or vapour fresh air should be inhaled. Keep airways free. If vomiting and if insensible place patient in recovery position and keep airways free.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing immediately. Rinse the affected skin or mucous membrane thoroughly for min. 15 minutes under running water. (If possible) use soap. Then apply a loose bandage.

Symptoms:

Rapid penetration and destruction of the skin. Especially in the heated form. Causes severe skin burns.

๐Ÿ‘๏ธ Eye Contact

After contact with the eyes rinse thoroughly under running water with the eyelid wide open for min. 10 minutes with eye washing bottle, eye douche or running water (protect intact eye). Before (if possible) apply eye drops Proxymetacaine 0.5%, if the opening the eyelid convulsion is painful. Further treatment to be carried out by an eye specialist.

๐Ÿฝ๏ธ Ingestion/Swallowing

After oral intake lots of water with activated charcoal supplement should be drunk after it has been ingested. Contact medical advice for possible consequences.

๐Ÿšจ Immediate Medical Attention Required

If necessary contact medical advice. Show product package, packing insert and this material safety data sheet to the doctor. Further treatment to be carried out by an eye specialist. Contact medical advice for possible consequences. In the event of RESPIRATORY DISTREES ensure that the patient inhales oxygen.

Medical Treatment

Apply glucocorticosteroides following inflammatory reactions. Eyelid convulsion measures. Administer aluminium oxide drug suspensions. Administer a prophylaxis to counter pulmonary oedema following the INGESTION of corrosive aerosols. In the event of RESPIRATORY DISTREES ensure that the patient inhales oxygen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
blue
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
acetic
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
4.5-5.5
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.12 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good ventilation and extraction system in the room, floor resistant to chemicals with floor drainage and washing facilities.

๐Ÿงค Hand Protection

Gloves according EN 374 (permeation time >30 min - level 2), consist of PVC, natural latex, Neopren, or Nitril (f.ex. from Ansell or KCL). Use for short times chemical resistant latex gloves with code EN 374-3 level 1.

๐Ÿ‘๏ธ Eye Protection

Safety glasses according EN 166 with integrated side shields or wrap-around protection or face protection.

๐Ÿ˜ท Respiratory Protection

No additional recommendations.

๐Ÿฆบ Skin/Body Protection

Recommended to avoid clothing damage, and to avoid contamination with these hazards.

๐ŸŒ Environmental Exposure Controls

Do not release product into environment.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3316

๐Ÿ“ฆ Proper Shipping Name

Chemical kit

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for NucleoSpin Gel and PCR Clean-up (50)?

The signal word for this substance is "danger".

What is the physical form of NucleoSpin Gel and PCR Clean-up (50)?

NucleoSpin Gel and PCR Clean-up (50) is a liquid with blue color. It has acetic odor.

What is NucleoSpin Gel and PCR Clean-up (50) used for?

Product for analytical use.

What are the hazard statements for NucleoSpin Gel and PCR Clean-up (50)?

This substance has 1 hazard statements: H314: Causes severe skin burns and eye damage.