Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NucleoSpin Gel and PCR Clean-up (50)
Product Code
740609.50

Regulatory Identifiers

CAS Number
N/A
REACH No.
A registration number for the substance(s) does not exist because the annual tonnage does not require registration or the substance or its use is excluded from registration.
UFI Code
N5XV-533V-Y202-95TW

Identified Uses

Product for analytical use. Exposure Scenario Classification according REACH, RIP 3.2 Codes: SU 0-2, PC 21, PROC 15, AC 0

Uses advised against

not described

Manufacturers & Suppliers

MACHEREY-NAGEL GmbH & Co. KG logo

MACHEREY-NAGEL GmbH & Co. KG

manufacturer

Valenciennen Str. 11, 52355 Duren, Germany

+49 2421 969 0

http://www.mn-net.com

Emergency Contacts

Gemeinsames Giftinformationszentrum (GGIZ)

+49 361 730 730

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 4 H302
Skin Corr. Cat. 1B H314
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H314 Causes severe skin burns and eye damage.

Precautionary Statements

P260 Do not breathe dust/vapours.
P264 Wash hands thoroughly after handling.
P280 Wear protective gloves/eye protection.
P303 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water (or shower).
P305 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER/doctor.
P405 Store locked up.
P501 Dispose of contents/container to regulated waste treatment.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

When not listed, mixtures are added with water [CAS No. 7732-18-5] to 100%.

Chemical Name CAS Number Concentration Hazardous
guanidinium thiocyanate EC: 209-812-1 593-84-0 30 - 45% Yes
indicator dye(s) --- 0.1% No
chemicals/mixture until 1% --- 0.1 - 1% No
water 7732-18-5 --- No

Notes

List of H and P phrases: see section 16.2.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation of foam or vapour fresh air should be inhaled. Keep airways free. If vomiting and if insensible place patient in recovery position and keep airways free.

Skin contact

Remove contaminated clothing immediately. Rinse the affected skin or mucous membrane thoroughly for min. 15 minutes under running water. (If possible) use soap. Avoid neutralisation. Then apply a loose bandage.

Symptoms: Rapid penetration and destruction of the skin. Especially in the heated form. Causes severe skin burns.

Eye contact

After contact with the eyes rinse thoroughly under running water with the eyelid wide open for min. 10 minutes with eye washing bottle, eye douche or running water (protect intact eye). Before (if possible) apply eye drops Proxymetacaine 0.5%, if the opening the eyelid convulsion is painful. Further treatment to be carried out by an eye specialist.

Symptoms: Causes severe eye damage.

Ingestion

After oral intake lots of water with activated charcoal supplement should be drunk after it has been ingested. Do not induce vomiting under any circumstances. Do not make any efforts to neutralise it. Contact medical advice for possible consequences.

Immediate Medical Attention

Contact medical advice for possible consequences. Further treatment to be carried out by an eye specialist.

Medical Treatment

Apply glucocorticosteroides following inflammatory reactions. Administer aluminium oxide drug suspensions. Administer a prophylaxis to counter pulmonary oedema following the INGESTION of corrosive aerosols. In the event of RESPIRATORY DISTREES ensure that the patient inhales oxygen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All extinguishers like FOAM, WATER SPRAY, DRY POWDER, CARBON DIOXIDE can be used.

Unsuitable media

no data available

Specific hazards

Formation of hazardous and caustic vapour-air mixtures possible.

Instructions

Spray any vapours released with water. Retent fire water. Use only acid-resistant safety equipment.

Firefighter Protection

For great amount - if necessary - protective breathing apparatus which is independent of the ambient air (isolated equipment), and sealed protective clothing is necessary in the event of a large-scale formation of toxic substances.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Regular staff training is necessary, indicating hazards and precautions on the basis of operating instructions. Restrictions on activity must be observed.

Small spill

Collect small amounts of leaked liquid and flush with water into drains.

Environmental

Should not be released into the environment.

Cleanup methods

Clean any contaminated equipment and floors with plenty of water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handling in accordance with the test instruction, that comes with the product.

Storage

Safe storage is guaranteed in the original packaging from MACHEREY-NAGEL. Keep original product packages tightly closed during handling and storage. Use inbreakable container for transport of glass bottles.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good ventilation and extraction system in the room, floor resistant to chemicals with floor drainage and washing facilities.

Hands

Yes, gloves according EN 374 (permeation time >30 min - level 2), consist of PVC, natural latex, Neopren, or Nitril (f.ex. from Ansell or KCL). Use for short times chemical resistant latex gloves with code EN 374-3 level 1.

Eyes

Yes, safety glasses according EN 166 with integrated side shields or wrap-around protection or face protection.

Respiratory

No additional recommendations.

Skin/Body

Recommended to avoid clothing damage, and to avoid contamination with these hazards.

Environmental

Do not release product into environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Kinematic Viscosity
no data available
Decomposition Temperature
no data available
Solubility In Fat
---
Colour Intensity
---
Appearance
---
Crystallisation Point
---
Auto Ignition Temperature
---
Freezing Point
---
Vapor Density
---
State Under Standard Conditions
---
Lower Explosive Limit
no data available
Dynamic Viscosity
---
Ph
4.5-5.5
Colour
blue
Partition Coefficient
no data available
Softening Point
---
Density
1.12 g/cm
Relative Density
1.12 g/cm³
Odor
acetic
Upper Explosive Limit
no data available
Physical State Data
liquid
Bulk Density
---
Melting Point
no data available
Physical State
liquid
Solubility In Water
no data available
Relative Evaporation Rate
---
Properties Status
---
Solidification Point
---
Solubility
---
Cloud Point
---
Vapor Pressure
no data available
Flammability
no data available
Evaporation Rate
---
Explosive Limits
---
Voc Content
---
Boiling Point
no data available
Metal Corrosion
Substances are highly corrosive.
Form
---
Odor Threshold
---
Flash Point
no data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

no known instability.

Reactivity

no further data available.

Hazardous reactions

Can react violently with organic material. Note: Can form very reactive substances with oxidizing agents. Possible: &H:EUH031& No further data available.

Avoid

No more required.

Incompatible

no additional data available

Decomposition

In the original package all parts/all reagents are safety and separated stored. Decompositions are not observed during the expiration period under recommended conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Normally it is possible to empty small amounts (diluted!) into drains.

Disposal

Please observe local regulations for collection and disposal of hazardous waste and contact waste disposal company, where you will obtain information on laboratory waste disposal.

Waste Codes

16 05 06 laboratory waste EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3316
Shipping Name
Chemical kit
Transport Class
9
Packing Group
II
ADR

not necessary

IMDG

251

IATA

not necessary

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

If necessary, observe other country-specific regulations.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NucleoSpin Gel and PCR Clean-up (50)?

The signal word is danger.

What is the physical form of NucleoSpin Gel and PCR Clean-up (50)?

NucleoSpin Gel and PCR Clean-up (50) is a liquid with blue color. It has acetic odor.

What is NucleoSpin Gel and PCR Clean-up (50) used for?

Product for analytical use. Exposure Scenario Classification according REACH, RIP 3.2 Codes: SU 0-2, PC 21, PROC 15, AC 0

What are the hazard statements for NucleoSpin Gel and PCR Clean-up (50)?

This substance has 1 hazard statement:

  • H314: Causes severe skin burns and eye damage.

What is the melting point of NucleoSpin Gel and PCR Clean-up (50)?

The melting point is no data available and the boiling point is no data available.