Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Orisil M130, M200, M300, hydrophobic fumed Silica
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Auxiliary agent for plastics, lacquer, building materials, elastomer products.
Manufacturers & Suppliers
ORISIL, Ltd.
manufacturer
31, Schevchenko Street, 79039, Lviv, Ukraine
Chemservice GmbH
Von-Steuben-Straße 13, D-67549 Worms, Germany
+49 6241-95480-0
Emergency Contacts
ORISIL, Ltd.
+380 32 2971219
during office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
- Chemical characterization: - CAS No. Description 68611-44-9 Silane, dichlorodimethyl-, reaction products with silica - Identification number(s) - EINECS Number: 271-893-4
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silane, dichlorodimethyl-, reaction products with silica EC: 271-893-4 | 68611-44-9 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air.
Immediately wash with water and soap and rinse thoroughly.
Symptoms: skin irritation
Rinse opened eye for several minutes under running water.
Rinse out mouth and then drink plenty of water.
Immediate Medical Attention
Consult doctor in case of complaints or if symptoms persist.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.
Water with full jet
Cool endangered receptacles with water spray.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow product to reach sewage system or any water course.
Pick up mechanically.
Related Products
Similar products with comparable safety profiles
Orisil 150, 200, 300, 380, hydrophilic amorphous fumed silica
CAS: 7631-86-9, 112945-52-5
Orisil 150, 200, 300, 380, hydrophilic amorphous fumed silica
CAS: 7631-86-9 112945-52-5
Fumed Silicia Suspension 0,2 μm anhydrous
---
Silica gel orange
CAS: 112926-00-8
Silica gel
CAS: 7631-86-9
Silica gel
CAS: 112926-00-8
AEROSIL® 200
CAS: 112945-52-5, 7631-86-9
1H,1H,2H,2H-Perfluorooctylmethyldichlorosilane
CAS: 73609-36-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Any unavoidable deposit of dust must be regularly removed. Protect from contamination.
Store in cool, dry conditions in well sealed receptacles.
Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Butyl rubber, BR, Nitrile rubber, NBR, PVC gloves. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses
Use suitable respiratory protective device in case of insufficient ventilation.
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
Risk of dust explosion.
Risk of dust explosion.
No decomposition if used according to specifications.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Orisil M130, M200, M300, hydrophobic fumed Silica?
The signal word is no signal word.
What is the physical form of Orisil M130, M200, M300, hydrophobic fumed Silica?
Orisil M130, M200, M300, hydrophobic fumed Silica is a solid with white color. It has odourless odor.
What is Orisil M130, M200, M300, hydrophobic fumed Silica used for?
Auxiliary agent for plastics, lacquer, building materials, elastomer products.
What is the melting point of Orisil M130, M200, M300, hydrophobic fumed Silica?
The melting point is 1700°C and the boiling point is 2230°C.