Product Name
Orisil M130, M200, M300, hydrophobic fumed Silica

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Auxiliary agent for plastics, lacquer, building materials, elastomer products.

Manufacturers & Suppliers

O

ORISIL, Ltd.

manufacturer

31, Schevchenko Street, 79039, Lviv, Ukraine

C

Chemservice GmbH

Von-Steuben-Straße 13, D-67549 Worms, Germany

+49 6241-95480-0

Emergency Contacts

ORISIL, Ltd.

+380 32 2971219

during office hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb

- Chemical characterization: - CAS No. Description 68611-44-9 Silane, dichlorodimethyl-, reaction products with silica - Identification number(s) - EINECS Number: 271-893-4

Chemical Name CAS Number Concentration Hazardous
Silane, dichlorodimethyl-, reaction products with silica EC: 271-893-4 68611-44-9 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Symptoms: skin irritation

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Rinse out mouth and then drink plenty of water.

Immediate Medical Attention

Consult doctor in case of complaints or if symptoms persist.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.

Unsuitable media

Water with full jet

Instructions

Cool endangered receptacles with water spray.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow product to reach sewage system or any water course.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Any unavoidable deposit of dust must be regularly removed. Protect from contamination.

Storage

Store in cool, dry conditions in well sealed receptacles.

Fire prevention

Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Butyl rubber, BR, Nitrile rubber, NBR, PVC gloves. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Use suitable respiratory protective device in case of insufficient ventilation.

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Relative Density
---
Metal Corrosion
---
Dynamic Viscosity
---
Colour Intensity
---
Kinematic Viscosity
---
Density
2.2 g/cm³
Softening Point
---
Appearance
---
Lower Explosive Limit
---
Cloud Point
---
Solidification Point
---
Crystallisation Point
---
Decomposition Temperature
---
Explosive Limits
---
Melting Point
1700°C
Flammability
Product is not flammable.
Bulk Density
---
Properties Status
---
Colour
White
Flash Point
Undetermined.
Voc Content
---
Solubility
---
Physical State Data
solid
Auto Ignition Temperature
400°C
Odor
Odourless
Evaporation Rate
---
Vapor Pressure
not determined
Partition Coefficient
---
Molecular Weight
---
Physical State
solid
Freezing Point
---
Form
Powder
Relative Evaporation Rate
---
Ph
3.5-5.5
Odor Threshold
---
Solubility In Water
Insoluble.
Boiling Point
2230°C
Upper Explosive Limit
---
Vapor Density
---
Solubility In Fat
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

Risk of dust explosion.

Hazardous reactions

Risk of dust explosion.

Avoid

No decomposition if used according to specifications.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Orisil M130, M200, M300, hydrophobic fumed Silica?

The signal word is no signal word.

What is the physical form of Orisil M130, M200, M300, hydrophobic fumed Silica?

Orisil M130, M200, M300, hydrophobic fumed Silica is a solid with white color. It has odourless odor.

What is Orisil M130, M200, M300, hydrophobic fumed Silica used for?

Auxiliary agent for plastics, lacquer, building materials, elastomer products.

What is the melting point of Orisil M130, M200, M300, hydrophobic fumed Silica?

The melting point is 1700°C and the boiling point is 2230°C.