NextSDS Logo
Safety Data Sheet EN

Fumed Silicia Suspension 0,2 m anhydrous

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Fumed Silicia Suspension 0,2 m anhydrous
Product Form
Mixture
Product Code
Oxypol009/010

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Sample preparation for metallography

Manufacturers & Suppliers

Cloeren Technology GmbH logo

Cloeren Technology GmbH

In Petersholz 44 DE 41844 Wegberg Germany

02432/8902510

www.cloeren.de

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302
STOT RE Cat. 2 H373

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 Harmful if swallowed.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P260 Do not breathe spray, mist, vapours.
P264 Wash hands thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P314 Get medical advice/attention if you feel unwell.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with harmless additives

Chemical Name CAS Number Concentration Hazardous
Monoethylenglykol EC: 203-473-3 107-21-1 --- No
Silicon Dioxide (amorphous) EC: 231-545-4 7631-86-9 --- No

Notes

Product contains nanoparticles

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing.

Skin contact

Wash skin with plenty of water.

Eye contact

Rinse eyes with water as a precaution.

Ingestion

Rinse mouth. Call a poison center or a doctor if you feel unwell.

Immediate Medical Attention

Treat symptomatically.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation of the work station.

Hands

The glove material must be impermeable and resistant to the product / the substance / the be preparation. Selection of the glove material taking into account the penetration times, permeation rates and the Degradation. Recommendation: uvex u-chem 3000 (DIN EN 374) Material: nitrile rubber Material thickness: 0.5 mm Value for the permeation:> 120 min (level 4) Recommendation: uvex u-fit strong N2000 (DIN EN 374) Material: nitrile rubber Material thickness: 0.2 mm Value for the permeation:> 30 min (level 2)

Eyes

Safety goggles recommended during refilling

Respiratory

Ensure adequate ventilation or use a fume cupboard. No respiratory protection is required with normal use.

Skin/Body

Wear suitable protective clothing

Environmental

Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
white.
Colour Intensity
---
Form
---
Odor
perceptible.
Odor Threshold
Not available
Ph
Not available
Melting Point
-13 C
Boiling Point
198
Flash Point
111 C
Freezing Point
Not available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not available
Vapor Density
---
Relative Density
Not available
Bulk Density
---
Density
1.2 g/cm
Flammability
Not applicable
Upper Explosive Limit
15.3 vol %
Lower Explosive Limit
3.2 vol %
Explosive Limits
---
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
soluble in water.
Partition Coefficient
Not available
Solubility In Water
soluble in water.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Fumed Silicia Suspension 0,2 m anhydrous?

The signal word is warning.

What is the physical form of Fumed Silicia Suspension 0,2 m anhydrous?

Fumed Silicia Suspension 0,2 m anhydrous is a liquid with white. color. It has perceptible. odor.

What is the solubility of Fumed Silicia Suspension 0,2 m anhydrous?

soluble in water.

What is Fumed Silicia Suspension 0,2 m anhydrous used for?

Sample preparation for metallography

What are the hazard statements for Fumed Silicia Suspension 0,2 m anhydrous?

This substance has 2 hazard statements:

  • H302: Harmful if swallowed.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of Fumed Silicia Suspension 0,2 m anhydrous?

The melting point is -13 C and the boiling point is 198.

Compliance Scanner

Scan your compliance