NextSDS Logo
Safety Data Sheet EN

di-Sodium hydrogen phosphate heptahydrate for analysis EMSURE® ACS

CAS 7782-85-6

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
di-Sodium hydrogen phosphate heptahydrate for analysis EMSURE® ACS
Product Code
1.06575
Chemical Name
di-Sodium hydrogen phosphate heptahydrate

Regulatory Identifiers

CAS Number
7782-85-6 Check regulations →
REACH No.
01-2119489797-11-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Na2HPO4 · 7H2O EC: 231-448-7 7782-85-6 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Fire may cause evolution of: Oxides of phosphorus. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry. Recommended storage temperature see product label.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P1. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
No data available
Relative Evaporation Rate
---
Relative Density
1,68
Appearance
---
Flammability
The product is not flammable.
Molecular Weight
---
Odor Threshold
---
Solubility In Water
No data available
Flash Point
Not applicable
Physical State
solid
Upper Explosive Limit
No data available
Dynamic Viscosity
No data available
Ph
9,0 - 9,3 at 50 g/l at 25 °C
Cloud Point
---
Partition Coefficient
No data available
Crystallisation Point
---
Melting Point
No data available
Bulk Density
ca.800 kg/m3
Freezing Point
---
State Under Standard Conditions
---
Physical State Data
solid
Lower Explosive Limit
No data available
Colour Intensity
---
Decomposition Temperature
No data available
Softening Point
---
Explosive Limits
---
Solubility
---
Vapor Density
---
Form
---
Auto Ignition Temperature
No data available
Voc Content
---
Colour
white
Properties Status
---
Evaporation Rate
---
Solubility In Fat
---
Metal Corrosion
---
Odor
No data available
Density
ca.1,68 g/cm3 at 20 °C
Vapor Pressure
---
Boiling Point
No data available
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Exothermic reaction with: Strong acids, antipyrine, Lead, acetates

Avoid

Exposure to moisture.

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for di-Sodium hydrogen phosphate heptahydrate for analysis EMSURE® ACS?

The signal word is no signal word.

What is the physical form of di-Sodium hydrogen phosphate heptahydrate for analysis EMSURE® ACS?

di-Sodium hydrogen phosphate heptahydrate for analysis EMSURE® ACS is a solid with white color. It has no data available odor.

What is di-Sodium hydrogen phosphate heptahydrate for analysis EMSURE® ACS used for?

Reagent for analysis

What is the melting point of di-Sodium hydrogen phosphate heptahydrate for analysis EMSURE® ACS?

The melting point is No data available and the boiling point is No data available.