NextSDS Logo
Safety Data Sheet EN

di-Sodium hydrogen phosphate dihydrate for analysis EMSURE®

CAS 10028-24-7

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
di-Sodium hydrogen phosphate dihydrate for analysis EMSURE®
Product Code
106580

Regulatory Identifiers

CAS Number
10028-24-7 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Formula Na₂HPO₄ * 2 H₂O HNa₂O₄P * 2 H₂O (Hill) EC-No. 231-448-7 Molar mass 177,99 g/mol

Chemical Name CAS Number Concentration Hazardous
di-Sodium hydrogen phosphate dihydrate for analysis EMSURE® EC: 231-448-7 --- --- No

The Safety Data Sheets for catalogue items are available at www.merckgroup.com

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/shower.

Eye contact

rinse out with plenty of water.

Ingestion

make victim drink water (two glasses at most).

Immediate Medical Attention

Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

full contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatri® L (full contact), KCL 741 Dermatri® L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Safety glasses

Respiratory

required when dusts are generated. Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
off-white
Colour Intensity
---
Form
solid
Odor
odourless
Odor Threshold
Not applicable
Ph
9,0 - 9,4 at 50 g/l 20 °C
Melting Point
92,5 °C Elimination of water of crystallisation
Boiling Point
No information available.
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No information available.
Vapor Pressure
No information available.
Vapor Density
---
Relative Density
No information available.
Bulk Density
ca.850 - 1.000 kg/m³
Density
2,1 g/cm³ at 20 °C
Flammability
The product is not flammable.
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
---
Auto Ignition Temperature
No information available.
Decomposition Temperature
ca.95 °C
Solubility
---
Partition Coefficient
No information available.
Solubility In Water
93 g/l at 20 °C
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No information available.
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

releases water of crystallisation when heated.

Reactivity

See section 10.3

Hazardous reactions

Exothermic reaction with: Strong acids, antipyrine, acetates

Avoid

Strong heating.

Incompatible

no information available

Decomposition

in the event of fire: See section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for di-Sodium hydrogen phosphate dihydrate for analysis EMSURE®?

The signal word is no signal word.

What is the physical form of di-Sodium hydrogen phosphate dihydrate for analysis EMSURE®?

di-Sodium hydrogen phosphate dihydrate for analysis EMSURE® is a solid with off-white color. It has odourless odor.

What is di-Sodium hydrogen phosphate dihydrate for analysis EMSURE® used for?

Reagent for analysis

What is the melting point of di-Sodium hydrogen phosphate dihydrate for analysis EMSURE®?

The melting point is 92,5 °C Elimination of water of crystallisation and the boiling point is No information available..