Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- KODAK RP X-OMAT Developer Replenisher, Part B
- Product Code
- 6610000B - Part B
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
photographic processing chemical. For industrial use only.
Manufacturers & Suppliers
KODAK LIMITED
manufacturer
Building 8, Croxley Green Business Park, Hatters Lane, Watford, WD18 8PX, Great Britain
0870-2430270
Emergency Contacts
Emergency Contact
844 892 0111
Available during office hours only
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The data for this section has not been processed yet.
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If not breathing, give artificial respiration using mouth guards or shields, when available, to avoid mouth-to-mouth contact. If breathing is difficult, give oxygen. If experiencing respiratory symptoms: Call a POISON CENTER or doctor/ physician.
In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician or poison control centre immediately. Wash contaminated clothing before re-use. Destroy or thoroughly clean contaminated shoes.
Immediately flush the contaminated eye(s) with water for at least 60 minutes, while holding the eyelid(s) open. If a contact lens is present, DO NOT delay irrigation or attempt to remove the lens. Neutral saline solution may be used as soon as it is available. DO NOT INTERRUPT FLUSHING. Contact a physician or poison control center immediately. Continue flushing the eye(s) until the physician advises to stop. If necessary, continue flushing during transport to an emergency care facility.
If swallowed, DO NOT induce vomiting. Rinse mouth. Get medical attention immediately.
Immediate Medical Attention
Call a POISON CENTER or doctor/ physician (inhalation). Call a physician or poison control centre immediately (skin). Contact a physician or poison control center immediately (eyes). Get medical attention immediately (ingestion).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
No flashpoint in conventional closed cup tester but forms flammable vapour-air mixtures in larger volumes at temperatures above 49°C (120°F). Material contains a combustible solvent that may accumulate in the container headspace.
Use water spray to cool unopened containers.
Firefighter Protection
Wear self-contained breathing apparatus and protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to protective measures listed in sections 7 and 8.
Contaminated absorbent should be disposed of in accordance with local regulations.
Absorb spill with vermiculite or other inert absorbant material such as sand or earth, then place in a suitable container for proper disposal. Clean surface thoroughly with water to remove residual contamination.
Materials: vermiculite, sand, earth
Related Products
Similar products with comparable safety profiles
KODAK RP X-OMAT LO Fixer and Replenisher, Part B
---
KODAK RP X-OMAT LO Fixer and Replenisher, Part A
---
X-OMAT EX II Developer and Replenisher, Part A
---
BONDERITE M-ZN CD-3020 R G-A ZINC PHOSPHATE REPLENISHER
---
BONDERITE M-ZN 3410 R ZINC PHOSPHATE REPLENISHER
---
UNIPART SCREENWASH CONCENTRATE
---
SUPRACARE™ 150M Additive
---
BONDERITE M-ZN 2798 R B ZINC PHOSPHATE REPLENISHER PA26KG
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid breathing mist or vapour. Avoid contact with eyes, skin, and clothing. Wash thoroughly after handling. Use with adequate ventilation.
Cool conditions (5 - 30°C). Keep container tightly closed.
Wash thoroughly after handling.
Keep away from heat and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions.
Using the information provided in Section 2, seek the advice of the glove supplier as to the most suitable glove material. Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure. Use chemical resistant gloves. In case of prolonged immersion or frequently repeated contact: Consult your glove manufacturer. Consult your glove manufacturer for advice on what glove material to avoid. The protective gloves to be used must comply with the specifications of the EC directive 89/686/EEC and the resultant standard EN 374. This recommendation applies only to the product stated in the Safety Data Sheet and supplied by us as well as to the purpose specified by us.
Wear safety glasses with side shields (or goggles) and a face shield.
If engineering controls do not maintain airborne concentrations below recommended exposure limits, an approved respirator must be worn. If respirators are used, a program should be instituted to assure compliance with applicable federal, state, commonwealth, provincial, or local laws and regulations.
Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No data available
Hazardous polymerisation does not occur.
No data available
Strong oxidizing agents, Bases, Amines, Metals.
Carbon oxides, Nitrogen oxides (NOx)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2790
- Shipping Name
- ACETIC ACID SOLUTION
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for KODAK RP X-OMAT Developer Replenisher, Part B?
The signal word is danger.
What is the physical form of KODAK RP X-OMAT Developer Replenisher, Part B?
KODAK RP X-OMAT Developer Replenisher, Part B is a liquid with orange color. It has pungent odor.
What is KODAK RP X-OMAT Developer Replenisher, Part B used for?
photographic processing chemical. For industrial use only.
What are the hazard statements for KODAK RP X-OMAT Developer Replenisher, Part B?
This substance has 11 hazard statements:
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H312: Harmful in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H360: Blood
- H360: Testes
- H361: Suspected of damaging fertility or the unborn child.
- H372: May cause damage to organs through prolonged or repeated exposure.
- H412: Harmful to aquatic life with long lasting effects.