Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- KODAK RP X-OMAT LO Fixer and Replenisher, Part A
- Product Code
- 6610018 - Part A
- Synonyms
- 5961
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
photographic processing chemical. For industrial use only.
Manufacturers & Suppliers
KODAK LIMITED
manufacturer
Building 8, Croxley Green Business Park, Hatters Lane, Watford, WD18 8PX, Great Britain
0870-2430270
Emergency Contacts
Emergency Contact
844 892 0111
Available during office hours only
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ammonium thiosulphate EC: 231-982-0 | 7783-18-8 | 35 - 40% | No |
| Acetic acid EC: 200-580-7 | 64-19-7 | 1 - 5% | Yes |
| ammonium hydrogensulphite EC: 233-469-7 | 10192-30-0 | 1 - 5% | Yes |
| Sodium hydrogensulfite EC: 231-548-0 | 7631-90-5 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
IF ON SKIN: Wash with plenty of soap and water.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Give victim a glass of water.
Immediate Medical Attention
Get medical attention if symptoms occur. If skin irritation occurs: Get medical advice/ attention. If eye irritation persists: Get medical advice/ attention. Get medical attention immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use appropriate agent for adjacent fire.
Dried product residue can act as a reducing agent.
Firefighter Protection
Wear self-contained breathing apparatus and protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to protective measures listed in sections 7 and 8.
Contaminated absorbent should be disposed of in accordance with local regulations.
Absorb spill with vermiculite or other inert absorbant material such as sand or earth, then place in a suitable container for proper disposal. Clean surface thoroughly with water to remove residual contamination.
Materials: vermiculite or other inert absorbant material such as sand or earth
Related Products
Similar products with comparable safety profiles
KODAK RP X-OMAT LO Fixer and Replenisher, Part B
---
KODAK RP X-OMAT Developer Replenisher, Part B
---
X-OMAT EX II Developer and Replenisher, Part A
---
Automat XR Fixer concentrate
---
ARDROX 9PR5 (+ HFR / OVERCHEK REMOVER) (AEROSOL)
---
BONDERITE M-ZN CD-3020 R G-A ZINC PHOSPHATE REPLENISHER
---
UNIPART SCREENWASH CONCENTRATE
---
BONDERITE M-ZN 3410 R ZINC PHOSPHATE REPLENISHER
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid breathing mist or vapour. Avoid contact with eyes, skin, and clothing. Use with adequate ventilation. Wash thoroughly after handling.
Cool conditions (5 - 30°C). Keep container tightly closed to prevent the loss of water.
Wash thoroughly after handling.
Keep from contact with oxidizing materials.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Avoid exposure to mists and vapours by mixing solutions in closed vessels and/or under local exhaust ventilation. Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions.
Using the information provided in Section 2, seek the advice of the glove supplier as to the most suitable glove material. Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure. Use chemical resistant gloves. In case of prolonged immersion or frequently repeated contact: Consult your glove manufacturer. Consult your glove manufacturer for advice on what glove material to avoid. The protective gloves to be used must comply with the specifications of the EC directive 89/686/EEC and the resultant standard EN 374. This recommendation applies only to the product stated in the Safety Data Sheet and supplied by us as well as to the purpose specified by us.
Wear safety glasses with side shields or protective goggles whenever mixing or handling solutions.
In case of insufficient ventilation, wear personal respiratory protection designed to protect against both aerosols and acid gas.
Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No data available
Hazardous polymerisation does not occur.
No data available
Acids, Strong bases, sodium hypochlorite (bleach), Halogenated compounds, Oxidizing agents. Contact with strong acids may liberate sulphur dioxide. Contact with strong bases may liberate ammonia. Contact with sodium hypochlorite (bleach) may liberate hazardous materials.
Carbon oxides, Ammonia, chloramine, Sulphur oxides, Nitrogen oxides (NOx)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is KODAK RP X-OMAT LO Fixer and Replenisher, Part A known by?
KODAK RP X-OMAT LO Fixer and Replenisher, Part A is also known as: 5961
What is the hazard signal word for KODAK RP X-OMAT LO Fixer and Replenisher, Part A?
The signal word is warning.
What is the physical form of KODAK RP X-OMAT LO Fixer and Replenisher, Part A?
KODAK RP X-OMAT LO Fixer and Replenisher, Part A is a liquid with light yellow color. It has vinegar odor.
What is KODAK RP X-OMAT LO Fixer and Replenisher, Part A used for?
photographic processing chemical. For industrial use only.
What are the hazard statements for KODAK RP X-OMAT LO Fixer and Replenisher, Part A?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of KODAK RP X-OMAT LO Fixer and Replenisher, Part A?
The melting point is No data available and the boiling point is > 100 °C (> 212.0 °F).