NextSDS Logo
Safety Data Sheet EN

KODAK RP X-OMAT LO Fixer and Replenisher, Part A

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
KODAK RP X-OMAT LO Fixer and Replenisher, Part A
Product Code
6610018 - Part A
Synonyms
5961

Regulatory Identifiers

CAS Number
N/A

Identified Uses

photographic processing chemical. For industrial use only.

Manufacturers & Suppliers

K

KODAK LIMITED

manufacturer

Building 8, Croxley Green Business Park, Hatters Lane, Watford, WD18 8PX, Great Britain

0870-2430270

Emergency Contacts

Emergency Contact

844 892 0111

Available during office hours only

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Dam. Cat. 2A H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash thoroughly after handling.
P280 Wear protective gloves/ eye protection/ face protection.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P332 + P313 If skin irritation occurs: Get medical advice/ attention.
P337 + P313 If eye irritation persists: Get medical advice/ attention.
P362 + P364 Take off contaminated clothing and wash before reuse.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
ammonium thiosulphate EC: 231-982-0 7783-18-8 35 - 40% No
Acetic acid EC: 200-580-7 64-19-7 1 - 5% Yes
ammonium hydrogensulphite EC: 233-469-7 10192-30-0 1 - 5% Yes
Sodium hydrogensulfite EC: 231-548-0 7631-90-5 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Skin contact

IF ON SKIN: Wash with plenty of soap and water.

Eye contact

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Give victim a glass of water.

Immediate Medical Attention

Get medical attention if symptoms occur. If skin irritation occurs: Get medical advice/ attention. If eye irritation persists: Get medical advice/ attention. Get medical attention immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use appropriate agent for adjacent fire.

Specific hazards

Dried product residue can act as a reducing agent.

Firefighter Protection

Wear self-contained breathing apparatus and protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Refer to protective measures listed in sections 7 and 8.

Environmental

Contaminated absorbent should be disposed of in accordance with local regulations.

Cleanup methods

Absorb spill with vermiculite or other inert absorbant material such as sand or earth, then place in a suitable container for proper disposal. Clean surface thoroughly with water to remove residual contamination.

Materials: vermiculite or other inert absorbant material such as sand or earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid breathing mist or vapour. Avoid contact with eyes, skin, and clothing. Use with adequate ventilation. Wash thoroughly after handling.

Storage

Cool conditions (5 - 30°C). Keep container tightly closed to prevent the loss of water.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep from contact with oxidizing materials.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Avoid exposure to mists and vapours by mixing solutions in closed vessels and/or under local exhaust ventilation. Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions.

Hands

Using the information provided in Section 2, seek the advice of the glove supplier as to the most suitable glove material. Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure. Use chemical resistant gloves. In case of prolonged immersion or frequently repeated contact: Consult your glove manufacturer. Consult your glove manufacturer for advice on what glove material to avoid. The protective gloves to be used must comply with the specifications of the EC directive 89/686/EEC and the resultant standard EN 374. This recommendation applies only to the product stated in the Safety Data Sheet and supplied by us as well as to the purpose specified by us.

Eyes

Wear safety glasses with side shields or protective goggles whenever mixing or handling solutions.

Respiratory

In case of insufficient ventilation, wear personal respiratory protection designed to protect against both aerosols and acid gas.

Skin/Body

Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
light yellow
Colour Intensity
---
Form
---
Odor
vinegar
Odor Threshold
No data available
Ph
4.8
Melting Point
No data available
Boiling Point
> 100 °C (> 212.0 °F)
Flash Point
does not flash
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
24 mbar (18.0 mm Hg) (at 20.0 °C (68.0 °F))
Vapor Density
0.6
Relative Density
1.29
Bulk Density
---
Density
---
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
complete
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No data available

Hazardous reactions

Hazardous polymerisation does not occur.

Avoid

No data available

Incompatible

Acids, Strong bases, sodium hypochlorite (bleach), Halogenated compounds, Oxidizing agents. Contact with strong acids may liberate sulphur dioxide. Contact with strong bases may liberate ammonia. Contact with sodium hypochlorite (bleach) may liberate hazardous materials.

Decomposition

Carbon oxides, Ammonia, chloramine, Sulphur oxides, Nitrogen oxides (NOx)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is KODAK RP X-OMAT LO Fixer and Replenisher, Part A known by?

KODAK RP X-OMAT LO Fixer and Replenisher, Part A is also known as: 5961

What is the hazard signal word for KODAK RP X-OMAT LO Fixer and Replenisher, Part A?

The signal word is warning.

What is the physical form of KODAK RP X-OMAT LO Fixer and Replenisher, Part A?

KODAK RP X-OMAT LO Fixer and Replenisher, Part A is a liquid with light yellow color. It has vinegar odor.

What is KODAK RP X-OMAT LO Fixer and Replenisher, Part A used for?

photographic processing chemical. For industrial use only.

What are the hazard statements for KODAK RP X-OMAT LO Fixer and Replenisher, Part A?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

What is the melting point of KODAK RP X-OMAT LO Fixer and Replenisher, Part A?

The melting point is No data available and the boiling point is > 100 °C (> 212.0 °F).