Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- KODAK RP X-OMAT LO Fixer and Replenisher, Part B
- Product Code
- 6610133 - Part B
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
photographic processing chemical (fixer). For industrial use only.
Manufacturers & Suppliers
KODAK LIMITED
manufacturer
Building 8, Croxley Green Business Park, Hatters Lane, Watford, WD18 8PX, Great Britain
0870-2430270
Emergency Contacts
Emergency Contact
844 892 0111
Available during office hours only
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| aluminium sulphate EC: 233-135-0 | 10043-01-3 | 20 - 25% | Yes |
| A mixture of: 5-chloro-2-methyl-2H-isothiazol-3-one [EC No 247-500-7] and 2-methyl-2H-isothiazol-3-one [EC No 220-239-6] (3:1) | 55965-84-9 | 0.0015 - 0.3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If symptomatic, move to fresh air. Get medical attention if symptoms occur.
Immediately flush with plenty of water for at least 15 minutes and wash using soap. Get medical attention if symptoms occur.
In case of contact with eyes, flush immediately with plenty of water and seek medical attention.
Do NOT induce vomiting. Give victim a glass of water. Get medical attention immediately. Never give anything by mouth to an unconscious person.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use appropriate agent for adjacent fire.
Firefighter Protection
Wear self-contained breathing apparatus and protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to protective measures listed in sections 7 and 8.
Contaminated absorbent should be disposed of in accordance with local regulations.
Absorb spill with vermiculite or other inert absorbant material such as sand or earth, then place in a suitable container for proper disposal. Clean surface thoroughly with water to remove residual contamination.
Materials: vermiculite or other inert absorbant material such as sand or earth
Related Products
Similar products with comparable safety profiles
KODAK RP X-OMAT LO Fixer and Replenisher, Part A
---
KODAK RP X-OMAT Developer Replenisher, Part B
---
X-OMAT EX II Developer and Replenisher, Part A
---
Automat XR Fixer concentrate
---
BONDERITE M-ZN CD-3020 R G-A ZINC PHOSPHATE REPLENISHER
---
BONDERITE M-ZN 3410 R ZINC PHOSPHATE REPLENISHER
---
DPX Mountant / DPX 2nd Generation
---
UNIPART SCREENWASH CONCENTRATE
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid prolonged or repeated breathing of mist or vapour. Avoid contact with eyes, skin, and clothing. Use only with adequate ventilation. Wash thoroughly after handling. Do not eat, drink or smoke when using this product.
Cool conditions (5 - 30°C). Keep container tightly closed. Keep away from incompatible substances (see Incompatibility section.)
Wash thoroughly after handling. Do not eat, drink or smoke when using this product.
No special precautionary measures should be needed under anticipated conditions of use.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Avoid exposure to mists and vapours by mixing solutions in closed vessels and/or under local exhaust ventilation. Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions.
Using the information provided in Section 2, seek the advice of the glove supplier as to the most suitable glove material. Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure. Use chemical resistant gloves. In case of prolonged immersion or frequently repeated contact: Nitrile rubber (>= 0.38 mm, > 480 min), Neoprene (>= 0.65 mm, > 240 min), butyl-rubber (>= 0.36 mm, > 480 min). Avoid natural rubber gloves. The protective gloves to be used must comply with the specifications of the EC directive 89/686/EEC and the resultant standard EN 374. This recommendation applies only to the product stated in the Safety Data Sheet and supplied by us as well as to the purpose specified by us.
Wear safety glasses with side shields or protective goggles whenever mixing or handling solutions.
None should be needed under normal conditions of use.
Avoid skin contact when mixing or handling the substance/preparation or a mixture by wearing impervious gloves and protective clothing appropriate to the risk of exposure.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No data available
Hazardous polymerisation does not occur.
No data available
Metals.
Sulphur oxides, aluminum oxides. Exposure to temperatures in excess of 180°C may liberate hazardous decomposition products including oxides of carbon, nitrogen and sulphur.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3264
- Shipping Name
- CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. (aluminum sulphate)
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for KODAK RP X-OMAT LO Fixer and Replenisher, Part B?
The signal word is warning.
What is the physical form of KODAK RP X-OMAT LO Fixer and Replenisher, Part B?
KODAK RP X-OMAT LO Fixer and Replenisher, Part B is a liquid with colourless color. It has odourless odor.
What is KODAK RP X-OMAT LO Fixer and Replenisher, Part B used for?
photographic processing chemical (fixer). For industrial use only.
What are the hazard statements for KODAK RP X-OMAT LO Fixer and Replenisher, Part B?
This substance has 4 hazard statements:
- H290: May be corrosive to metals.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of KODAK RP X-OMAT LO Fixer and Replenisher, Part B?
The melting point is No data available and the boiling point is > 100 °C (> 212.0 °F).