Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Lacomit stopping-off Lacquer
Product Code
AGG371

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Epoxy resin hardener for use in microscopy.

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

A

Agar Scientific, Elektron Technology UK Ltd

manufacturer

Parsonage Lane, Stansted CM24 8GF, United Kingdom

+44 (0) 1279 813 519

Emergency Contacts

Emergency Contact

+44 (0)1856 407333

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Eye Dam. Cat. 1 H318
Skin Irrit. Cat. 2 H315
STOT SE Cat. 3 H335

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H226 Flammable liquid and vapour.
H315 Causes skin irritation.
H318 Causes serious eye damage.
H335 May cause respiratory irritation. May cause drowsiness or dizziness.

Precautionary Statements

Keep out of the reach of children.
Wear suitable protective clothing and gloves.
If swallowed, seek medical advice immediately and show this container or label.
Dispose of this material and its container to hazardous or special waste collection point.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
xylene EC: 215-535-7 1330-20-7 45% Yes
butan-1-ol EC: 200-751-6 71-36-3 20% Yes
n-butyl acetate EC: 204-658-1 123-86-4 20% Yes
acetone EC: 200-662-2 67-64-1 5% Yes
1-methoxy-2-propanol EC: 203-539-1 107-98-2 5% Yes
Amine, Kolophonium-, Verbindungen mit 9-(2-Carboxyphenyl)-3,6-bis(diethylamino)xanthylliumchlorid und Dinatriumhydrogenbis(4-(4,5-dihydro-3-methyl-5-oxo-1-phenyl-1H-pyrazol-4-yl)azo)-3-hydroxy-1-naphthalinsulfonato(3-))chromat(3-) EC: 308-114-5 97862-65-2 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist. In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, sand, extinguishing powder.

Unsuitable media

Water, Water with full jet

Instructions

Advice for firefighters

Firefighter Protection

Protective equipment: Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.

Storage

Keep container tightly sealed.

Fire prevention

Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Crystallisation Point
---
Flash Point
30 °C
Vapor Pressure
10.7 hPa (at 20 °C)
Explosive Limits
---
Colour Intensity
---
Relative Density
Not determined.
Odor Threshold
Not determined.
Decomposition Temperature
Not determined.
Melting Point
Undetermined.
Cloud Point
---
Density
Not determined.
Partition Coefficient
Not determined.
Physical State Data
liquid
Colour
According to product specification
Boiling Point
137 °C
Upper Explosive Limit
9.4 Vol %
Flammability
Not applicable.
Ph
Not determined.
Softening Point
---
Appearance
---
Physical State
liquid
Solubility In Water
Not miscible or difficult to mix.
Relative Evaporation Rate
---
Metal Corrosion
---
Voc Content
95.00 %
Auto Ignition Temperature
270 °C
Molecular Weight
---
Kinematic Viscosity
Not determined.
Properties Status
---
Lower Explosive Limit
1.1 Vol %
Bulk Density
---
Form
Fluid
Solubility In Fat
---
Odor
Characteristic
Dynamic Viscosity
Not determined.
State Under Standard Conditions
---
Solubility
---
Solidification Point
---
Vapor Density
Not determined.
Evaporation Rate
Not determined.
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable if used according to specifications.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
PAINT, solution
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lacomit stopping-off Lacquer?

The signal word is danger.

What is the physical form of Lacomit stopping-off Lacquer?

Lacomit stopping-off Lacquer is a liquid with according to product specification color. It has characteristic odor.

What is Lacomit stopping-off Lacquer used for?

Epoxy resin hardener for use in microscopy.

What are the hazard statements for Lacomit stopping-off Lacquer?

This substance has 4 hazard statements:

  • H226: Flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.
  • H335: May cause respiratory irritation. May cause drowsiness or dizziness.

What is the melting point of Lacomit stopping-off Lacquer?

The melting point is Undetermined. and the boiling point is 137 °C.