Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Watertight Roof Sealant
- Product Code
- 070798182707
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Caulking Compound
Manufacturers & Suppliers
DAP Global Inc.
manufacturer
2400 Boston Street Suite 200, Baltimore, MD 21224-4723
888-327-8477
Emergency Contacts
Transportation
1-800-535-5053
Transportation
1-352-323-3500
Poison Control
1-800-222-1222
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Cellulose | 9004-34-6 | 3 - 7% | No |
| Asphalt | 8052-42-4 | 30 - 60% | Yes |
| Calcium Carbonate | 471-34-1 | 15 - 40% | Yes |
| Stoddard solvent | 8052-41-3 | 10 - 30% | Yes |
| Attapulgite | 12174-11-7 | 3 - 7% | Yes |
| Respirable crystalline silica | 14808-60-7 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If breathing is difficult, leave the area to obtain fresh air. If continued breathing difficulty is experienced, get medical attention immediately. If there are signs or symptoms of hydrogen sulfide exposure, move the person to fresh air. If breathing has stopped, apply artificial respiration. Call a doctor.
Symptoms: respiratory tract irritation, headache, dizziness, nausea, gastrointestinal disturbances, coughing, a sensation of dryness and pain in the nose, throat and chest, confusion and unconsciousness
Wash skin with soap and water for 15 minutes. Get medical aid if symptoms persist. Remove and wash contaminated clothing.
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention immediately.
If swallowed, DO NOT INDUCE VOMITING. Get medical attention immediately.
Immediate Medical Attention
Get medical attention immediately for inhalation, eye contact, and ingestion. Get medical aid if skin symptoms persist.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog, Water
No Information
Wear self contained breathing apparatus for fire fighting if necessary.
Firefighter Protection
Wear self contained breathing apparatus for fire fighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations.
No Information
absorb with inert material and dispose of in accordance with applicable regulations.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Ultra Clear Waterproof Roof Sealant Cartridge
---
Waterproof Patch & Seal Liquid (Clear)
---
Ultra Clear Waterproof Roof Sealant Brush Grade
---
DAP Ultra Clear Flexible Waterproof Sealant
---
Waterproof Patch & Seal Spray (Clear)
---
Waterproof Patch & Seal Liquid (White)
---
Loctite PL Polyurethane Roof and Flashing Sealant
---
Seal N Peel Removable Weatherstrip Sealant
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
KEEP OUT OF REACH OF CHILDREN! DO NOT TAKE INTERNALLY. Keep containers closed when not in use. Avoid breathing vapor and contact with eyes, skin and clothing. Use in well ventilated area. Wash thoroughly after handling.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal temperatures and pressures.
Excessive heat and freezing. Avoid contact with skin, eyes and clothing.
Strong acids and strong bases.
Carbon monoxide, carbon dioxide, nitrogen oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3175
- Shipping Name
- Solids containing flammable liquid, n.o.s.
- Transport Class
- 4.1 Flammable solid
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Watertight Roof Sealant?
The signal word is danger.
What is the physical form of Watertight Roof Sealant?
Watertight Roof Sealant is a solid appearing as paste with black color. It has strong solvent odor.
What is Watertight Roof Sealant used for?
Caulking Compound
What are the hazard statements for Watertight Roof Sealant?
This substance has 4 hazard statements:
- H315: Causes skin irritation.
- H335: May cause respiratory irritation.
- H350: May cause cancer.
- H372: Causes damage to organs through prolonged or repeated exposure.