Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE L-GP SN 400C CORROSION INHIBITOR
- Product Code
- 598278
- Synonyms
- P3 PREVOX SN-400C
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial Metal Working Agents
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Mineral oil | --- | 10 - 30% | Yes |
| 2-methylpentane-2,4-diol | 107-41-5 | 5 - 10% | Yes |
| Barium sulfonate | 61790-48-5 | 1 - 5% | Yes |
| Distillates (petroleum), hydrotreated heavy naphthenic | 64742-52-5 | 30 - 60% | Yes |
Notes
*Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If mist or vapor of this product is inhaled, remove person immediately to fresh air. Seek medical attention if symptoms develop or persist.
Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Immediate medical treatment necessary. DO NOT induce vomiting unless directed to do so by medical personnel.
Immediate Medical Attention
Immediate medical treatment necessary.
Medical Treatment
This material, if aspirated into the lungs, may cause chemical pneumonitis; treat the affected person appropriately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE L-GP 4232 CORROSION INHIBITOR
---
BONDERITE L-GP 5800 CORROSION INHIBITOR
---
BONDERITE S-FN 6750 CORROSION PROTECTIVE COATING
---
BONDERITE L-CA CP 791
---
BONDERITE L-GP GP 460 ACHESON
---
BONDERITE L-GP 808 ACHESON
---
BONDERITE C-NE 3300
---
BONDERITE C-IC A-500 DEOXIDIZER
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing vapors or mists of this product. Do not take internally. For industrial use only.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Manufacturer recommends storing above 4.4 °C (40 °F). Thaw and mix thoroughly if frozen.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
None under normal processing.
Heat, flames, sparks and other sources of ignition.
Strong oxidizing agents.
Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is BONDERITE L-GP SN 400C CORROSION INHIBITOR known by?
BONDERITE L-GP SN 400C CORROSION INHIBITOR is also known as: P3 PREVOX SN-400C
What is the hazard signal word for BONDERITE L-GP SN 400C CORROSION INHIBITOR?
The signal word is danger.
What is the physical form of BONDERITE L-GP SN 400C CORROSION INHIBITOR?
BONDERITE L-GP SN 400C CORROSION INHIBITOR is a liquid with brown color. It has petroleum odor.
What is the solubility of BONDERITE L-GP SN 400C CORROSION INHIBITOR?
Complete Water
What is BONDERITE L-GP SN 400C CORROSION INHIBITOR used for?
Industrial Metal Working Agents
What are the hazard statements for BONDERITE L-GP SN 400C CORROSION INHIBITOR?
This substance has 3 hazard statements:
- H304: MAY BE FATAL IF SWALLOWED AND ENTERS AIRWAYS.
- H315: CAUSES SKIN IRRITATION.
- H319: CAUSES SERIOUS EYE IRRITATION.
What is the melting point of BONDERITE L-GP SN 400C CORROSION INHIBITOR?
The melting point is Not available. and the boiling point is 215 °F (101.7 °C) None.