Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SINMAST P103 A' Comp.
- Synonyms
- W-SHIELD, ICCP EPOXY FILLER
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
SINTECNO SA
4, Anaxagora str., P.O.Box 202, PC 194 00, Koropi, Attica, GREECE
0030 210 6026020
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Reaction product : bisphenol-A-(epichlorhydrin) epoxy resin (number average molecular weight ≤ 700) EC: 500-033-5 | 25068-38-6 | 25 - 55% | Yes |
| 2.3-epoxypropyl o-tolyl ether EC: 218-645-3 | 2210-79-9 | 5 - 20% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air. Use a respiratory bag or breathing device. Call a doctor immediately. In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly. Clean with detergents. Avoid solvents.
Call a doctor immediately. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Administer medicinal carbon. Drink plenty of water and provide fresh air. Call for a doctor immediately. Do not induce vomiting: call for medical help immediately.
Immediate Medical Attention
Call a doctor immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions
Carbon dioxides. Burning produces obnoxious and toxic fumes
Firefighter Protection
Wear self-contained respiratory protective device
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers / surface or ground water.
Residues can be removed with solvent. Solvents are not recommended for cleanup unless the recommended exposure guidelines and safe handling practices for the specific solvent are followed.
Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Store in cool, dry conditions in well sealed receptacles
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. The glove material has to be impermeable and resistant to the product / the substance / the preparation. Due to missing tests no recommendation to the glove material can be given for the product/the preparation/the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Synthetic rubber gloves. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
Filter AX, Filter P2. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer use self-contained respiratory protective device. Use suitable respiratory protective device in case of insufficient ventilation.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Reacts with strong acids and oxidizing agents
Take necessary action to avoid static electricity discharge; No further relevant information available
Strong acids and strong bases / Strong oxidizing agents
Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- environmentally hazardous substance, liquid, N.O.S.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is SINMAST P103 A' Comp. known by?
SINMAST P103 A' Comp. is also known as: W-SHIELD, ICCP EPOXY FILLER
What is the hazard signal word for SINMAST P103 A' Comp.?
The signal word is warning.
What is the physical form of SINMAST P103 A' Comp.?
SINMAST P103 A' Comp. is a paste appearing as paste with white color. It has characteristic odor.
What are the hazard statements for SINMAST P103 A' Comp.?
This substance has 5 hazard statements:
- H315: Causes skin irritation
- H317: May cause an allergic skin reaction
- H319: Causes serious eye irritation
- H341: Suspected of causing genetic defects
- H411: Toxic to aquatic life with long lasting effects
What is the melting point of SINMAST P103 A' Comp.?
The melting point is Undetermined and the boiling point is Undetermined.