NextSDS Logo
Safety Data Sheet EN

Amberlite® IRA-200C (Na), ion exchange resin

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Amberlite® IRA-200C (Na), ion exchange resin
Product Code
42252

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

T

Thermo Fisher (Kandel) GmbH

manufacturer

Erlenbachweg 2, 76870 Kandel, Germany

+49 (0) 721 84007 280

Fisher Scientific AG logo

Fisher Scientific AG

distributor

Neuhofstrasse 11, CH 4153 Reinach

+41 (0) 56 618 41 11

https://www.fishersci.ch/ch/en/customer-help-support/forms/email-us.html

Emergency Contacts

Emergency Contact

001-800-227-6701

Emergency Contact

+32 14 57 52 11

Emergency Contact

001-201-796-7100

Emergency Contact

+32 14 57 52 99

CHEMTREC

001-800-424-9300

CHEMTREC

001-703-527-3887

Tox Info Suisse

145

24hr

Tox Info Suisse

+41-44 251 51 51

Chemtrec

0800 564 402

24h

Chemtrec

+41-43 508 20 11

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Sodium vinylbenzenesulfonate, polymer with Divinylbenzene 63182-08-1 55% No
Water EC: 231-791-2 7732-18-5 45% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Ingestion

Clean mouth with water and drink afterwards plenty of water.

Immediate Medical Attention

Get medical attention. Get medical attention immediately if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO₂). Powder. Water spray.

Unsuitable media

No information available.

Specific hazards

Risk of explosion.

Instructions

Fight fire remotely due to the risk of explosion.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Should not be released into the environment. See Section 12 for additional Ecological Information.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid contact with skin, eyes or clothing. Avoid ingestion and inhalation. Avoid dust formation.

Storage

Keep container tightly closed in a dry and well-ventilated place.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves. Glove material: Butyl rubber. Breakthrough time: See manufacturers recommendations. Glove thickness: -. EU standard: EN 374. Glove comments: (minimum requirement)

Eyes

Wear safety glasses with side shields (or goggles) (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: In case of insufficient ventilation, wear suitable respiratory equipment. Recommended Filter type: Particle filter. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. When RPE is used a face piece Fit Test should be conducted

Skin/Body

Long sleeved clothing. Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid Beads
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
No data available
Ph
No information available
Melting Point
No data available
Boiling Point
No information available
Flash Point
No information available
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable - Solid
Vapor Pressure
No data available
Vapor Density
Not applicable
Relative Density
---
Bulk Density
No data available
Density
No data available
Flammability
Not applicable Solid
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
---
Solubility In Water
Insoluble in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known, based on information available

Hazardous reactions

None under normal processing. Hazardous Polymerization No information available.

Avoid

Incompatible products. Excess heat.

Incompatible

Oxidizing agent.

Decomposition

Sodium oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Amberlite® IRA-200C (Na), ion exchange resin?

The signal word is no signal word.

What is the physical form of Amberlite® IRA-200C (Na), ion exchange resin?

Amberlite® IRA-200C (Na), ion exchange resin is a solid beads . It has odorless odor.

What is Amberlite® IRA-200C (Na), ion exchange resin used for?

Laboratory chemicals.

What is the melting point of Amberlite® IRA-200C (Na), ion exchange resin?

The melting point is No data available and the boiling point is No information available.