NextSDS Logo
Safety Data Sheet EN

CHLOR*RID (EU)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CHLOR*RID (EU)
Product Code
137844

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Not available.

Uses advised against

None known.

Manufacturers & Suppliers

C

Corrosion Innovations

manufacturer

3500 South Richey Street, Suite 320, Houston, TX 77017

713-625-7537

Emergency Contacts

Emergency Contact

800-255-3924

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Hazard Statements

The mixture does not meet the criteria for classification.

Precautionary Statements

Observe good industrial hygiene practices.
Wash hands after handling.
Store away from incompatible materials.
Dispose of waste and residues in accordance with local authority requirements.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-4-isothiazolin-3-one (3:1) 55965-84-9 0.0015% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Call a physician if symptoms develop or persist.

Skin contact

Wash off with soap and water. Get medical attention if irritation develops and persists.

Eye contact

Rinse with water. Get medical attention if irritation develops and persists.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

During fire, gases hazardous to health may be formed.

Instructions

Move containers from fire area if you can do so without risk. Use standard firefighting procedures and consider the hazards of other involved materials.

Firefighter Protection

Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

For non-emergency personnel: Keep unnecessary personnel away. For personal protection, see section 8 of the SDS. For emergency responders: Keep unnecessary personnel away. Use personal protection recommended in Section 8 of the SDS.

Small spill

Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Large spill

Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.

Environmental

Avoid discharge into drains, water courses or onto the ground.

Cleanup methods

Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water. Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Materials: vermiculite, dry sand, earth, absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe good industrial hygiene practices.

Storage

Store in original tightly closed container.

Hygiene

Observe good industrial hygiene practices.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Use protective gloves made of: Polyvinyl chloride (PVC). Nitrile.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Wear suitable protective clothing.

Environmental

Environmental manager must be informed of all major releases.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Blue
Colour Intensity
---
Form
Liquid.
Odor
Not available.
Odor Threshold
Not available.
Ph
3 - 3,5
Melting Point
Not available.
Boiling Point
> 100 °C (> 212 °F)
Flash Point
Not available.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
Not available.
Bulk Density
---
Density
1,01 g/cm³ (20°C)
Flammability
Not applicable.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not available.
Solubility In Water
Not available.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

The product is stable and non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Avoid temperatures exceeding the flash point. Contact with incompatible materials.

Incompatible

Strong oxidising agents.

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CHLOR*RID (EU)?

The signal word is no signal word.

What is the physical form of CHLOR*RID (EU)?

CHLOR*RID (EU) is a liquid. with blue color. It has not available. odor.

What is CHLOR*RID (EU) used for?

Not available.

What are the hazard statements for CHLOR*RID (EU)?

This substance has 1 hazard statement:

  • The mixture does not meet the criteria for classification.

What is the melting point of CHLOR*RID (EU)?

The melting point is Not available. and the boiling point is > 100 °C (> 212 °F).