Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Synfluid® PAO 6 cSt HVI
- Product Code
- 10691074, 1113306, 1113305, 10691818
- Chemical Name
- 1-Dodecene, Trimer, Hydrogenated; 1-Dodecene, Homopolymer, Hydrogenated
Regulatory Identifiers
- CAS Number
- 151006-62-1, 151006-63-2 Check regulations →
- EC Number
- 417-070-7, 438-390-3 Check regulations →
- REACH No.
- 01-0000016388-62-0004, 01-0000018318-67-0002
Identified Uses
Formulation, Lubricants - Industrial, Lubricants - Professional, Lubricants - Consumer, Metal working fluids / rolling oils - Industrial, Metal working fluids / rolling oils – Professional, Functional Fluids - Industrial, Functional Fluids - Professional, Functional Fluids - Consumer
Manufacturers & Suppliers
Chevron Phillips Chemical Company LP
manufacturer
10001 Six Pines Drive, The Woodlands, TX 77380
(800) 852-5530
http://www.CPChem.com
Chevron Phillips Chemicals International N.V.
local supplier
Airport Plaza (Stockholm Building), Leonardo Da Vincilaan 19, 1831 Diegem, Belgium
Emergency Contacts
Health (North America)
866.442.9628
Health (International)
1.832.813.4984
CHEMTREC
800.424.9300
CHEMTREC
703.527.3887
CHEMWATCH
+612 9186 1132
China
0532 8388 9090
Mexico CHEMTREC
01-800-681-9531
24 hours
SOS-Cotec Inside Brazil
0800.111.767
SOS-Cotec Outside Brazil
+55.19.3467.1600
Argentina
+(54)-1159839431
BIG
+32.14.584545
VIZ
+43 1 406 43 43
24 hours/day, 7 days/week
Belgium
070 245 245
24 hours/day, 7 days/week
Bulgaria
+359 2 9154 233
Croatia
+3851 2348 342
24 hours/day, 7 days/week
Cyprus
1401
Toxicological Information Center
+420 224 919 293
Danish Poison Center (Giftlinjen)
+45 8212 1212
Finland
0800 147 111
24 hours/day
ORFILA number (INRS)
+33 (0) 1 45 42 59 59
24 hours/day, 7 days/week
Greece
(0030) 2107793777
24 hours/day, 7 days/week
Hungary
+36-80-201-199
24 hours/day, 7 days/week
Iceland
543 2222
24 hours/day, 7 days/week
Poisoning and Drug Information Center
+371 67042473
24 hours
Lithuania
+370 (85) 2362052
Luxembourg
(+352) 8002 5500
24 hours/day, 7 days/week
Malta
+356 2395 2000
NVIC
+31 (0)88 755 8000
Norway
22 59 13 00
24 hours/day, 7 days/week
CIAV
+351 800 250 250
Romania
+40213183606
Slovakia
+421 2 5477 4166
Slovenia
112
National Emergency Telephone Number of Spanish Poison Centre
+34 91 562 04 20
24 hours/day, 7 days/week
Sweden
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Synonyms : Polyalphaolefin PAO PAO Polyalphaolefin. Molecular formula : UVCB, UVCB
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Dodecene, Trimer, Hydrogenated EC: 417-070-7 | 151006-62-1 | 50 - 80% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
Remove contact lenses. Protect unharmed eye. If eye irritation persists, consult a specialist.
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Do not use a solid water stream as it may scatter and spread fire.
Do not use a solid water stream as it may scatter and spread fire. Cool closed containers exposed to fire with water spray.
Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas. Material can create slippery conditions.
No special environmental precautions required.
Wipe up with absorbent material (e.g. cloth, fleece).
Materials: absorbent material (e.g. cloth, fleece)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.
Electrical installations / working materials must comply with the technological safety standards.
Smoking, eating and drinking should be prohibited in the application area.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation to control airborne concentrations below the exposure guidelines/limits. Consider the potential hazards of this material (see Section 2), applicable exposure limits, job activities, and other substances in the work place when designing engineering controls and selecting personal protective equipment. If engineering controls or work practices are not adequate to prevent exposure to harmful levels of this material, the personal protective equipment listed below is recommended. The user should read and understand all instructions and limitations supplied with the equipment since protection is usually provided for a limited time or under certain circumstances.
The suitability for a specific workplace should be discussed with the producers of the protective gloves. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.
Eye wash bottle with pure water. Tightly fitting safety goggles.
Wear a supplied-air NIOSH approved respirator unless ventilation or other engineering controls are adequate to maintain minimal oxygen content of 19.5% by volume under normal atmospheric pressure. Wear a NIOSH approved respirator that provides protection when working with this material if exposure to harmful levels of airborne material may occur, such as.: Air-Purifying Respirator for Dusts and Mists / P100. Use a positive pressure, air-supplying respirator if there is potential for uncontrolled release, aerosolization, exposure levels are not known, or other circumstances where air-purifying respirators may not provide adequate protection.
Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place. Wear as appropriate.: Protective suit. Safety shoes.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if stored and applied as directed.
Stable at normal ambient temperature and pressure.
Further information: Stable under recommended storage conditions., No hazards to be specially mentioned.
No data available.
No data available.
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
If this material is classified as a hazardous waste, federal law requires disposal at a licensed hazardous waste disposal facility.
Use material for its intended purpose or recycle if possible.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product is in full compliance according to REACH regulation 1907/2006/EC.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Synfluid® PAO 6 cSt HVI?
The signal word is no signal word.
What is the physical form of Synfluid® PAO 6 cSt HVI?
Synfluid® PAO 6 cSt HVI is a liquid appearing as liquid with colorless color. It has odorless odor.
What is Synfluid® PAO 6 cSt HVI used for?
Formulation, Lubricants - Industrial, Lubricants - Professional, Lubricants - Consumer, Metal working fluids / rolling oils - Industrial, Metal working fluids / rolling oils – Professional, Functional Fluids - Industrial, Functional Fluids - Professional, Functional Fluids - Consumer