NextSDS Logo
Safety Data Sheet EN

Synfluid® PAO 6 cSt HVI

CAS 151006-62-1, 151006-63-2
EC 417-070-7, 438-390-3

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Synfluid® PAO 6 cSt HVI
Product Code
10691074, 1113306, 1113305, 10691818
Chemical Name
1-Dodecene, Trimer, Hydrogenated; 1-Dodecene, Homopolymer, Hydrogenated

Regulatory Identifiers

CAS Number
151006-62-1, 151006-63-2 Check regulations →
EC Number
417-070-7, 438-390-3 Check regulations →
REACH No.
01-0000016388-62-0004, 01-0000018318-67-0002

Identified Uses

Formulation, Lubricants - Industrial, Lubricants - Professional, Lubricants - Consumer, Metal working fluids / rolling oils - Industrial, Metal working fluids / rolling oils – Professional, Functional Fluids - Industrial, Functional Fluids - Professional, Functional Fluids - Consumer

Manufacturers & Suppliers

Chevron Phillips Chemical Company LP logo

Chevron Phillips Chemical Company LP

manufacturer

10001 Six Pines Drive, The Woodlands, TX 77380

(800) 852-5530

http://www.CPChem.com

C

Chevron Phillips Chemicals International N.V.

local supplier

Airport Plaza (Stockholm Building), Leonardo Da Vincilaan 19, 1831 Diegem, Belgium

Emergency Contacts

Health (North America)

866.442.9628

Health (International)

1.832.813.4984

CHEMTREC

800.424.9300

CHEMTREC

703.527.3887

CHEMWATCH

+612 9186 1132

China

0532 8388 9090

Mexico CHEMTREC

01-800-681-9531

24 hours

SOS-Cotec Inside Brazil

0800.111.767

SOS-Cotec Outside Brazil

+55.19.3467.1600

Argentina

+(54)-1159839431

BIG

+32.14.584545

VIZ

+43 1 406 43 43

24 hours/day, 7 days/week

Belgium

070 245 245

24 hours/day, 7 days/week

Bulgaria

+359 2 9154 233

Croatia

+3851 2348 342

24 hours/day, 7 days/week

Cyprus

1401

Toxicological Information Center

+420 224 919 293

Danish Poison Center (Giftlinjen)

+45 8212 1212

Finland

0800 147 111

24 hours/day

ORFILA number (INRS)

+33 (0) 1 45 42 59 59

24 hours/day, 7 days/week

Greece

(0030) 2107793777

24 hours/day, 7 days/week

Hungary

+36-80-201-199

24 hours/day, 7 days/week

Iceland

543 2222

24 hours/day, 7 days/week

Poisoning and Drug Information Center

+371 67042473

24 hours

Lithuania

+370 (85) 2362052

Luxembourg

(+352) 8002 5500

24 hours/day, 7 days/week

Malta

+356 2395 2000

NVIC

+31 (0)88 755 8000

Norway

22 59 13 00

24 hours/day, 7 days/week

CIAV

+351 800 250 250

Romania

+40213183606

Slovakia

+421 2 5477 4166

Slovenia

112

National Emergency Telephone Number of Spanish Poison Centre

+34 91 562 04 20

24 hours/day, 7 days/week

Sweden

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb

Synonyms : Polyalphaolefin PAO PAO Polyalphaolefin. Molecular formula : UVCB, UVCB

Chemical Name CAS Number Concentration Hazardous
1-Dodecene, Trimer, Hydrogenated EC: 417-070-7 151006-62-1 50 - 80% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Eye contact

Remove contact lenses. Protect unharmed eye. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable media

Do not use a solid water stream as it may scatter and spread fire.

Specific hazards

Do not use a solid water stream as it may scatter and spread fire. Cool closed containers exposed to fire with water spray.

Instructions

Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas. Material can create slippery conditions.

Environmental

No special environmental precautions required.

Cleanup methods

Wipe up with absorbent material (e.g. cloth, fleece).

Materials: absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.

Storage

Electrical installations / working materials must comply with the technological safety standards.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Adequate ventilation to control airborne concentrations below the exposure guidelines/limits. Consider the potential hazards of this material (see Section 2), applicable exposure limits, job activities, and other substances in the work place when designing engineering controls and selecting personal protective equipment. If engineering controls or work practices are not adequate to prevent exposure to harmful levels of this material, the personal protective equipment listed below is recommended. The user should read and understand all instructions and limitations supplied with the equipment since protection is usually provided for a limited time or under certain circumstances.

Hands

The suitability for a specific workplace should be discussed with the producers of the protective gloves. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.

Eyes

Eye wash bottle with pure water. Tightly fitting safety goggles.

Respiratory

Wear a supplied-air NIOSH approved respirator unless ventilation or other engineering controls are adequate to maintain minimal oxygen content of 19.5% by volume under normal atmospheric pressure. Wear a NIOSH approved respirator that provides protection when working with this material if exposure to harmful levels of airborne material may occur, such as.: Air-Purifying Respirator for Dusts and Mists / P100. Use a positive pressure, air-supplying respirator if there is potential for uncontrolled release, aerosolization, exposure levels are not known, or other circumstances where air-purifying respirators may not provide adequate protection.

Skin/Body

Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place. Wear as appropriate.: Protective suit. Safety shoes.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Relative Evaporation Rate
---
Relative Density
---
Softening Point
---
Freezing Point
---
Appearance
liquid
Colour
Colorless
Physical State Data
liquid
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Decomposition Temperature
---
Density
6,87 - 6,96 L/G
Colour Intensity
---
Physical State
liquid
Auto Ignition Temperature
351°C (664°F)
Properties Status
---
Melting Point
---
Metal Corrosion
---
Vapor Pressure
No data available
Explosive Limits
---
Voc Content
---
Solubility In Water
insoluble in water
Vapor Density
---
Partition Coefficient
---
Flash Point
246-271°C (475-520°F)
Ph
Not applicable
Form
liquid
Dynamic Viscosity
---
Molecular Weight
Not applicable
Evaporation Rate
No data available
Odor
Odorless
State Under Standard Conditions
---
Odor Threshold
---
Boiling Point
>260°C (>500°F)
Solidification Point
---
Solubility In Fat
---
Solubility
---
Flammability
---
Bulk Density
---
Kinematic Viscosity
29,5 cSt at 40°C (104°F)
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if stored and applied as directed.

Reactivity

Stable at normal ambient temperature and pressure.

Hazardous reactions

Further information: Stable under recommended storage conditions., No hazards to be specially mentioned.

Avoid

No data available.

Incompatible

No data available.

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

If this material is classified as a hazardous waste, federal law requires disposal at a licensed hazardous waste disposal facility.

Disposal

Use material for its intended purpose or recycle if possible.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This product is in full compliance according to REACH regulation 1907/2006/EC.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Synfluid® PAO 6 cSt HVI?

The signal word is no signal word.

What is the physical form of Synfluid® PAO 6 cSt HVI?

Synfluid® PAO 6 cSt HVI is a liquid appearing as liquid with colorless color. It has odorless odor.

What is Synfluid® PAO 6 cSt HVI used for?

Formulation, Lubricants - Industrial, Lubricants - Professional, Lubricants - Consumer, Metal working fluids / rolling oils - Industrial, Metal working fluids / rolling oils – Professional, Functional Fluids - Industrial, Functional Fluids - Professional, Functional Fluids - Consumer