Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Hydrogen peroxide 30% AnalaR NORMAPUR® for traces analysis
- Product Code
- 23615
Regulatory Identifiers
- CAS Number
- 7722-84-1 Check regulations →
Identified Uses
General chemical reagent
Manufacturers & Suppliers
VWR International Ltd.
national supplier
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN
0800 22 33 44
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrogen peroxide EC: 231-765-0 | 7722-84-1 | 30 - 35% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately call a POISON CENTRE/doctor. Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. In case of skin reactions, consult a physician.
Symptoms: skin reactions
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.
Immediately call a POISON CENTRE/doctor. Do NOT induce vomiting. Rinse mouth thoroughly with water. Give nothing to eat or drink.
Immediate Medical Attention
Immediately call a POISON CENTRE/doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product itself does not burn. May intensify fire; oxidiser. Co-ordinate fire-fighting measures to the fire surroundings.
no restriction
In case of fire may be liberated: Pyrolysis products, toxic
DO NOT fight fire when fire reaches explosives. Use water spray jet to protect personnel and to cool endangered containers.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In case of major fire and large quantities: Remove persons to safety.
Discharge into the environment must be avoided.
Collect in closed and suitable containers for disposal.
Related Products
Similar products with comparable safety profiles
Hydrogen peroxide 30% (Perhydrol TM) for analysis EMSURE® ISO
UFI: 9VPX-658R-V99Q-9WPY
Hydrogen peroxide 30% (Perhydrol®) (stabilized for higher storage temp.) for analysis EMSURE® ISO
---
Hydrogen peroxide, 29.0-32.0%
---
Petroleum spirit 40-60°C (max. 0.01% aromatic hydrocarbons) AnalaR NORMAPUR® ACS
CAS: 64742-49-0
Nitric acid 68% AnalaR NORMAPUR®
CAS: 7697-37-2
Nitric acid 65% AnalaR NORMAPUR®
CAS: 7697-37-2
Hydrogen Peroxide 30%
CAS: Mixture.
Hydrogen peroxide 6% (w/v; 20 vol.) GPR RECTAPUR®
CAS: 7722-84-1
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid: Inhalation Avoid contact with skin and eyes.
Keep container tightly closed and in a well-ventilated place. Keep/Store away from combustible materials. Due to gaseous decomposition products, overpressure can occur in tightly sealed containers. Container should not be closed gas-tight.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms: DIN EN 374 In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact: Suitable material: NBR (Nitrile rubber), Thickness of the glove material: 0,12 mm, Breakthrough time (maximum wearing time): 41 min, Recommended glove articles: VWR 112-0998. By long-term hand contact: Suitable material: NBR (Nitrile rubber), Thickness of the glove material: 0,38 mm, Breakthrough time (maximum wearing time): > 480 min, Recommended glove articles: VWR 112-3717 / 112-1381.
Eye glasses with side protection DIN-/EN-Norms: DIN EN 166. Recommendation: VWR 111-0432
Respiratory protection necessary at: aerosol or mist formation. Suitable respiratory protection apparatus: Full-/half-/quarter-face masks (DIN EN 136/140). Recommendation: VWR 111-0206. Suitable material: ABEK2P3. Recommendation: VWR 111-0059.
Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
no data available
The generally known reaction partners of water.
no data available
no data available
no data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2014
- Shipping Name
- HYDROGEN PEROXIDE, AQUEOUS SOLUTION
- Transport Class
- 5.1 (8)
- Packing Group
- II
Passage forbidden through tunnels of category E.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Hydrogen peroxide 30% AnalaR NORMAPUR® for traces analysis?
The signal word is danger.
What is the physical form of Hydrogen peroxide 30% AnalaR NORMAPUR® for traces analysis?
Hydrogen peroxide 30% AnalaR NORMAPUR® for traces analysis is a liquid with colourless color. It has no data available odor.
What is Hydrogen peroxide 30% AnalaR NORMAPUR® for traces analysis used for?
General chemical reagent
What are the hazard statements for Hydrogen peroxide 30% AnalaR NORMAPUR® for traces analysis?
This substance has 4 hazard statements:
- H272: May intensify fire; oxidiser.
- H290: May be corrosive to metals.
- H302 + H332: Harmful if swallowed or if inhaled.
- H318: Causes serious eye damage.
What is the melting point of Hydrogen peroxide 30% AnalaR NORMAPUR® for traces analysis?
The melting point is no data available and the boiling point is no data available.