Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Microscopes-Immersion Liquids for Light Microscopy
- Product Code
- IMMOIL-F30CC
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Oil for microscope, oil-immersion objective lenses
Manufacturers & Suppliers
Olympus Europa SE & Co. KG
manufacturer
Wendenstrasse 14-18, 20097 Hamburg, Germany
+49 40 2 37 73 5498
Emergency Contacts
Emergency Contact
+49 40 23 77 30
available during office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Product identifier (Product name): IMMOIL-F30CC
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Pheny-1-(3,4-dimethylphenyl) ethane EC: 228-249-2 | 6196-95-8 | 35% | Yes |
| 1,4-Dimethyl-2-(1-phenylethyl) benzene EC: 228-201-0 | 6165-51-1 | --- | Yes |
| 1-Phenyl-1-(2,4-xylyl)ethane EC: 228-202-6 | 6165-52-2 | --- | Yes |
| Ethyl(phenylethyl) benzene EC: 265-241-8 | 64800-83-5 | --- | Yes |
| Other ingredients (non hazardous) Trade secret and proprietary | --- | 65% | No |
Notes
As a mixture of four substances (CAS No; 6196-95-8, 6165-51-1, 6165-52-2 and 64800-83-5): Xn; R20/21/22-48/22-68/22, Xi; R38, R43, N; R51-53
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If you feel unwell, get medical attention.
Wash skin with running water and soap immediately. If skin irritation or rash occurs: Get medical advice/attention.
Symptoms: May cause an allergic skin reaction.
Rinse with clean water for at least 15 minutes and immediately get medical attention. Keep eyelids open with fingers so that eyeballs and all surfaces of eyes are flushed thoroughly.
Immediately induce vomiting and keep at rest and get medical attention. Rinse mouth.
Immediate Medical Attention
If skin irritation or rash occurs: Get medical advice/attention. Immediately get medical attention for eye contact. Get medical attention if ingested or if you feel unwell after inhalation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Fire foam, carbon dioxide or dry chemical powder
Discharging cylinder shape water from fire hose may lead to spread fire to the surroundings.
Combustible: This product burns but not easily ignited. Toxic gas and/or fume may generate by combustion.
Remove containers from fire area if it can be done without risk. Take action from upwind.
Firefighter Protection
Wear air respirators, chemical protective clothing during fire fighting. When extinguishing a fire in a confined area, be sure to wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stay in the windward. Immediately eliminate all sources of ignition such as open flame, hot surfaces, etc. Ventilate before entering a confined area.
For small spills, absorb with dry earth, sawdust, sand, etc and collect into a closed container then dispose of them.
For large spills, dike with earth and sand, etc. to prevent further spills and cover liquid surface with foam and collect into an empty container as much as possible.
Do not release to the environment. Care should be made so that any adverse effects on the environment will not cause by discharging the product into rivers, etc.
absorb with dry earth, sawdust, sand, etc and collect into a closed container then dispose of them.
Related Products
Similar products with comparable safety profiles
Immersion oil for microscopy
UFI: 0F32-R681-M99E-WTFA
Neo-Clear® (xylene substitute) for microscopy
CAS: 64741-65-7
Neo-Clear® (xylene substitute) for microscopy
CAS: 64741-65-7
Neo-Clear® (xylene substitute) for microscopy
CAS: 64741-65-7
DPX new non-aqueous mounting medium for microscopy
---
DPX new non-aqueous mounting medium for microscopy
UFI: RY2Y-J5KR-299H-J1V2
Immersion Oil, 150 CS
---
Fluorescence Mounting Medium
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not inhale or swallow. Avoid contact with eyes and skin.
Keep container tightly closed and store in a well-ventilated place.
Wash hands thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace.
Keep away from sources of ignition such as open flame, static discharge, electric sparks, etc. Use non-sparking tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle the product only under conditions where sufficient ventilation is provided and/or in a closed system. Install eye washer and safety shower near handling and storage area and display where they are.
Wear oil-resistant protective gloves
Wear suitable safety glasses.
Wear gas mask for organic gas, air-supplied respirators, air respirators, etc.
work clothing as appropriate.
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This product is stable to light or heat.
This product is considered to be a non-reactive material under normal and anticipated storage and handling conditions.
No information
Sources of ignition such as hot surfaces, sparks, open flames, etc.
See Section 7.
No information
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s.
- Transport Class
- Class 9 (Environmentally hazardous substances: aquatic environment)
- Packing Group
- III
Confirm no damages, corrosion and leakages of containers before transportation. Load dangerous goods and containers in a way of no falling, overturning or damage. During transportation, avoid exposure to direct sunlight and load containers in a way to prevent damage, corrosion and leakage. Secure prevention of cargo collapse. If a disaster occurs by accident, etc during transportation, notify fire station and other relevant agencies of it at first. Do not stack heavy objects on the top of cargos.
Confirm no damages, corrosion and leakages of containers before transportation. Load dangerous goods and containers in a way of no falling, overturning or damage. During transportation, avoid exposure to direct sunlight and load containers in a way to prevent damage, corrosion and leakage. Secure prevention of cargo collapse. If a disaster occurs by accident, etc during transportation, notify fire station and other relevant agencies of it at first. Do not stack heavy objects on the top of cargos.
Confirm no damages, corrosion and leakages of containers before transportation. Load dangerous goods and containers in a way of no falling, overturning or damage. During transportation, avoid exposure to direct sunlight and load containers in a way to prevent damage, corrosion and leakage. Secure prevention of cargo collapse. If a disaster occurs by accident, etc during transportation, notify fire station and other relevant agencies of it at first. Do not stack heavy objects on the top of cargos.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Microscopes-Immersion Liquids for Light Microscopy?
The signal word is warning.
What is the physical form of Microscopes-Immersion Liquids for Light Microscopy?
Microscopes-Immersion Liquids for Light Microscopy is a liquid appearing as clear and colourless, slightly viscous liquid . It has faint aromatic odour odor.
What is the solubility of Microscopes-Immersion Liquids for Light Microscopy?
Almost insoluble in water
What is Microscopes-Immersion Liquids for Light Microscopy used for?
Oil for microscope, oil-immersion objective lenses
What are the hazard statements for Microscopes-Immersion Liquids for Light Microscopy?
This substance has 4 hazard statements:
- H317: May cause an allergic skin reaction.
- H371: May cause damage to organs (kidneys)
- H373: May cause damage to organs (adrenal, liver) through prolonged or repeated exposure.
- H411: Toxic to aquatic life with long lasting effects.