Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Biestral 5L
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- W001-G0DM-A00K-G2ND
Identified Uses
Cleaner (AISE_SUMI_PW_8a_2 // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_11_1 // AISE_SUMI_PW_11_4 // AISE_SUMI_PW_19_1)
Manufacturers & Suppliers
Produkten Bielen
national supplier
Walenstraat 65, 3500 Hasselt
+32011819141
http://www.bielenprodukten.be/
Emergency Contacts
Emergency Contact
+32 70 245 245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Sodium Dodecylbenzenesulphonate EC: 270-115-0 | 68411-30-3 | 7% | Yes |
| 2-(2-butoxyethoxy)ethanol EC: 203-961-6 | 112-34-5 | 5% | Yes |
| Sodium Laureth Sulfate EC: 500-234-8 | 68891-38-3 | 4% | Yes |
| Urea EC: 200-315-5 | 57-13-6 | 2% | No |
| potassium cocoate EC: 263-049-9 | 61789-30-8 | 2% | Yes |
| p-Menth-1-en-8-ol EC: 232-268-1 | 8000-41-7 | 1% | Yes |
| Ammonia, aqueous solution EC: 215-647-6 | 1336-21-6 | 0.2% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of serious or continuous discomforts: remove to fresh air and seek medical attention.
Rinse with water.
Symptoms: Redness, pain
Rinse first with plenty of water, if necessary seek medical attention.
Symptoms: Caustic, redness, blurred vision, pain
Rinse first with plenty of water, if necessary seek medical attention.
Symptoms: Diarrhoea, headache, abdominal cramps, sleepiness, vomiting
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, foam, powder, sprayed water
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not walk into or touch spilled substances and avoid inhalation of fumes, smoke, dusts and vapours by staying up wind. Remove any contaminated clothing and used contaminated protective equipment and dispose of it safely.
Do not allow to flow into sewers or open water.
remove by using absorbent material
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
Actisan-5L
---
GETRIEBEÖL CLP 220 205L
---
BIEVIT STEAMER GRILL- EN OVENREINIGER GEBRUIKSKLAAR 5L
UFI: AU20-U0A3-500G-NAC6
SBZ GPIII 4cSt
CAS: 72623-86-0
Spolostan 7L CaS FF
UFI: MJVS-SUQ1-G00V-JXSM
LOCTITE BZ 9120 5GAL AERO known as Epsilon 99120 5 Gallon
---
HSW 100 500ml
UFI: 7KK9-F030-T008-JQ5V
DW Shine Glass 3 5L
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle with care to avoid spillage.
Keep in a sealed container in a closed, frost-free, ventilated room.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Adequate ventilation should be provided so that exposure limits are not exceeded. For further information, check section 7.
Handling with nitril-gloves (EN 374). Breakthrough time: >480' Material thickness: 0,35 mm. Thoroughly check gloves before use. Take of the gloves properly without touching the outside with your bare hands. The manufacturer of the protective gloves has to be consulted about the suitability for a specific work station. Wash and dry your hands.
Keep an eye-rinse bottle within reach. Tight-fitting safety goggles. Wear a face shield and protective suit in case of exceptional processing problems.
Use with sufficient exhaust ventilation. If necessary, use an air-purifying face mask in case of respiratory hazards. Use the ABEK type as protection against these troublesome levels.
Wear impermeable clothing. The type of protective equipment depends on the concentration and amount of hazardous substances at the work station in question.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions. For further information, check sections 6 and 13.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Extremely high or low temperatures.
Stable under normal conditions.
Protect from sunlight and do not expose to temperatures exceeding + 50°C.
Acids, alkalines, oxidants, reductants
Under recommended usage conditions, hazardous decomposition products are not expected.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Biestral 5L?
The signal word is danger.
What is the physical form of Biestral 5L?
Biestral 5L is a liquid with yellow color. It has characteristic odor.
What is Biestral 5L used for?
Cleaner (AISE_SUMI_PW_8a_2 // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_11_1 // AISE_SUMI_PW_11_4 // AISE_SUMI_PW_19_1)
What are the hazard statements for Biestral 5L?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
What is the melting point of Biestral 5L?