NextSDS Logo
Safety Data Sheet EN

Leckfinder-Spray

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Leckfinder-Spray

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Auxiliary

Manufacturers & Suppliers

K

Klostermann Chemie GmbH & Co. KG

manufacturer

Von-Dem-Bussche-Münch-Straße 4, D-32339 Espelkamp

+49(0)5772 / 6711

Emergency Contacts

Beratungsstelle bei Vergiftungen, Mainz

+49(0)6131 / 19240

24 h von Mo. – So.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Aerosol H229

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H229 Pressurised container: May burst if heated.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P251 Do not pierce or burn, even after use.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb liquid components with liquid-binding material.

Materials: liquid-binding material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions are necessary if used correctly.

Storage

Recommended storage temperature: 10 - 30°C. Observe official regulations on storing packagings with pressurised containers.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Not required. As protection from splashes gloves made of the following materials are suitable: PVC or PE gloves. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Not required.

Respiratory

Not necessary if room is well-ventilated. When used properly and under normal conditions, breathing protection is not required.

Skin/Body

Light weight protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
Not applicable for an aerosol
Cloud Point
---
Decomposition Temperature
Not determined.
Kinematic Viscosity
---
Molecular Weight
---
Softening Point
---
Odor
Characteristic
Partition Coefficient
---
Boiling Point
Not applicable, as aerosol.
Solidification Point
---
Physical State
Aerosol
Bulk Density
---
Colour
Colourless
Relative Evaporation Rate
---
Flash Point
Not applicable, as aerosol.
Physical State Data
aerosol
Lower Explosive Limit
Not determined.
Solubility In Fat
---
Metal Corrosion
---
State Under Standard Conditions
---
Vapor Pressure
Not determined.
Auto Ignition Temperature
---
Relative Density
Not determined.
Form
---
Explosive Limits
---
Vapor Density
Not determined.
Crystallisation Point
---
Properties Status
---
Colour Intensity
---
Freezing Point
---
Density
0,993 g/cm³
Appearance
Aerosol
Upper Explosive Limit
Not determined.
Odor Threshold
Not determined.
Solubility
---
Flammability
Not applicable.
Dynamic Viscosity
---
Solubility In Water
Fully miscible.
Voc Content
---
Evaporation Rate
Not applicable.
Melting Point
Undetermined.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.2
Packing Group
Void
ADR

Warning: Gases.

IMDG

Warning: Gases.

IATA

Warning: Gases.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Leckfinder-Spray?

The signal word is warning.

What is the physical form of Leckfinder-Spray?

Leckfinder-Spray is a aerosol appearing as aerosol with colourless color. It has characteristic odor.

What is Leckfinder-Spray used for?

Auxiliary

What are the hazard statements for Leckfinder-Spray?

This substance has 1 hazard statement:

  • H229: Pressurised container: May burst if heated.

What is the melting point of Leckfinder-Spray?

The melting point is Undetermined. and the boiling point is Not applicable, as aerosol..