Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Propane
- Chemical Name
- Propane
- Synonyms
- Propel 110
Regulatory Identifiers
- CAS Number
- 74-98-6 Check regulations →
- EC Number
- 200-827-9 Check regulations →
- REACH No.
- 01-2119486944-21
Identified Uses
Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use. Under controlled conditions.
Uses advised against
Contact supplier for more information on uses. Uses other than those listed above are not supported.
Manufacturers & Suppliers
BOC
manufacturer
Priestley Road, Worsley, M28 2UT Manchester
0800 111 333
Emergency Contacts
Emergency Contact
0800 111 333
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS04
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Chemical name: Propane; Purity: 100%
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Propane EC: 200-827-9 | 74-98-6 | 100% | No |
The concentrations of the components in the SDS header, product name on page one and in section 3.2 are in mol due to regulatory requirements. All concentrations are nominal. This substance has workplace exposure limit(s). PBT: persistent, bioaccumulative and toxic substance. vPvB: very persistent and very bioaccumulative substance.
Notes
The purity of the substance in this section is used for classification only, and does not represent the actual purity of the substance as supplied, for which other documentation should be consulted.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Apply artificial respiration if breathing stopped.
Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
In case of frostbite spray with water for at least 15 minutes. Apply a sterile dressing. Get medical attention.
Symptoms: Contact with evaporating liquid may cause frostbite or freezing of skin.
Rinse the eye with water immediately. Remove contact lenses, if present and easy to do. Continue rinsing. Flush thoroughly with water for at least 15 minutes. Get immediate medical assistance. If medical assistance is not immediately available, flush an additional 15 minutes.
Ingestion is not considered a potential route of exposure.
Immediate Medical Attention
Call a doctor. Get immediate medical assistance. Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water Spray or Fog. Dry powder. Foam.
Carbon Dioxide.
Incomplete combustion may form carbon monoxide
In case of fire: Stop leak if safe to do so. Do not extinguish flames at leak because possibility of uncontrolled explosive reignition exists. Continue water spray from protected position until container stays cool. Use extinguishants to contain the fire. Isolate the source of the fire or let it burn out.
Firefighter Protection
Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA. Guideline: EN 469 Protective clothing for firefighters. Performance requirements for protective clothing for firefighting. EN 15090 Footwear for firefighters. EN 659 Protective gloves for firefighters. EN 443 Helmets for fire fighting in buildings and other structures. EN 137 Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with full face mask - Requirements, testing, marking.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate area. Provide adequate ventilation. Consider the risk of potentially explosive atmospheres. In case of leakage, eliminate all ignition sources.
Prevent further leakage or spillage if safe to do so.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Only experienced and properly instructed persons should handle gases under pressure. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Purge system with dry inert gas (e.g. helium or nitrogen) before gas is introduced and when system is placed out of service. Purge air from system before introducing gas. Assess the risk of a potentially explosive atmosphere and the need for suitable equipment i.e. explosion-proof. Take precautionary measures against static discharges. Keep away from ignition sources (including static discharges). Provide electrical earthing of equipment and electrical equipment usable in explosive atmospheres. Use non-sparking tools. Protect containers from physical damage; do not drag, roll, slide or drop. Secure cylinders in an upright position at all times, close all valves when not in use. Suck back of water into the container must be prevented. Do not allow backfeed into the container. Avoid suckback of water, acid and alkalis. When using do not eat, drink or smoke.
Keep container below 50°C in a well ventilated place. Secure cylinders in an upright position at all times, close all valves when not in use. Store in accordance with local/regional/national/international regulations.
The substance must be handled in accordance with good industrial hygiene and safety procedures. When using do not eat, drink or smoke.
Keep away from ignition sources (including static discharges). Provide electrical earthing of equipment.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Consider a work permit system e.g. for maintenance activities. Ensure adequate air ventilation. Provide adequate general and local exhaust ventilation. Keep concentrations well below lower explosion limits. Gas detectors should be used when quantities of flammable gases or vapours may be released. Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded. Systems under pressure should be regularly checked for leakages. Product to be handled in a closed system. Only use permanent leak tight installations (e.g. welded pipes). Take precautionary measures against static discharges.
Guideline: EN 388 Protective gloves against mechanical risks. Additional Information: Wear working gloves while handling containers
Safety eyewear, goggles or face-shield to EN166 should be used to avoid exposure to liquid splashes. Wear eye protection to EN 166 when using gases. Guideline: EN 166 Personal Eye Protection.
When allowed by a risk assessment Respiratory Protective Equipment (RPE) may be used The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD. Self-contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres Guideline: EN 137 Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with full face mask - Requirements, testing, marking.
Wear fire resistant or flame retardant clothing. Guideline: ISO/TR 2801:2007 Clothing for protection against heat and flame -- General recommendations for selection, care and use of protective clothing. Other: Wear safety shoes while handling containers. Guideline: ISO 20345 Personal protective equipment - Safety footwear.
Refer to local regulations for restriction of emissions to the atmosphere. See section 13 for specific methods for waste gas treatment. For waste disposal, see section 13 of the SDS.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No reactivity hazard other than the effects described in sub-section below.
Can form a potentially explosive atmosphere in air. May react violently with oxidants.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
oxidants
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1965
- Shipping Name
- HYDROCARBON GAS MIXTURE, LIQUEFIED, N.O.S.(Propane)
- Transport Class
- 2
Passenger and cargo aircraft: Forbidden. Cargo aircraft only: Allowed.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Propane known by?
Propane is also known as: Propel 110
What is the hazard signal word for Propane?
The signal word is danger.
What is the physical form of Propane?
Propane is a gas appearing as colorless with colorless color. It has odorless odor.
What is Propane used for?
Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use. Under controlled conditions.
What are the hazard statements for Propane?
This substance has 2 hazard statements:
- H220: Extremely flammable gas.
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of Propane?