Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
2700 Hard Hat Advanced Primer and Topcoat
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A
UFI Code
XDP1-V0K6-8008-AHJ6

Identified Uses

Consumer Industrial Professional

Uses advised against

None identified.

Manufacturers & Suppliers

R

RUST-OLEUM EUROPE Martin Mathys NV

manufacturer

Kolenbergstraat 23, B-3545 Zelem, Belgium

+32 (0) 13 460 200

T

Tor Coatings Limited

manufacturer

Unit 21, White Rose Way, Follingsby Park, Gateshead, Tyne & Wear, NE10 8YX United Kingdom

+44 (0) 191 4106611

Emergency Contacts

Poison centre

+32(0)70 245 245

Emergency Contact

+359 2 9154 409

Emergency Contact

+385 1 2348 342

Emergency Contact

1401

Toxikologické informační středisko

+420 224 919 293

Toxikologické informační středisko

+420 224 915 402

Giftlinien

82 12 12 12

open 24 hours a day

Emergency Contact

16662

Emergency Contact

0800 147 111

ORFILA (INRS)

+33 (0)1 45 42 59 59

24/7

Emergency Telephone Poison Center Nos. Children Aglaia Kyriakou

+30 210 7793777

Health Toxicology Information Service (ETTSZ)

(+ 36-80) 201-199

0-24 h

Emergency Contact

+354 5432222

Emergency Contact

809 2166

Available 8am to 10pm 7 days per week

Emergency Contact

800183459

Toxicology and sepsis clinics Poisoning and Drug Information Center

+371 67042473

Poison Information Office

+370 (5) 2362052

24 hours a day

Poison centre

+32(0)70 245 245

Emergency Contact

112

Emergency Contact

088-755 8000

Emergency Contact

+47 22 59 13 00

Emergency Contact

112

Emergency Contact

800 250 250

24/7

Emergency Contact

+40 21 318 36 06

Monday - Friday between 8:00 -15:00, local hour

NATIONAL TOXICOLOGICAL INFORMATION CENTER

+421 2 5477 4166

Non-stop 24-hour consultation

Emergency Contact

915 620 420

Poison Information Center

112

Swiss Toxicological Information Centre

145

24 h

Emergency Contact

809 2166

Available 8am to 10pm 7 days per week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol. Pressurised container: may burst if heated.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P103 Read carefully and follow all instructions.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P271 Use only outdoors or in a well-ventilated area.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
n-butyl acetate EC: 204-658-1 123-86-4 10 - 25% Yes
hydrocarbons, C10-C13, n-/ iso-/ cyclo-alkanes, < 2% aromatics EC: 918-481-9 --- 0.3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: respiratory tract irritation, coughing, nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness

Skin contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: irritation, dryness, cracking

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: irritation, redness

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

Extremely flammable aerosol. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion. Bursting aerosol containers may be propelled from a fire at high speed.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. In the case of aerosols being ruptured, care should be taken due to the rapid escape of the pressurised contents and propellant. If a large number of containers are ruptured, treat as a bulk material spillage according to the instructions in the clean-up section. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C. Do not pierce or burn, even after use. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Avoid breathing vapour or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous.

Storage

Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. > 8 hours (breakthrough time): polyethylene (PE), polyvinyl alcohol (PVA). The recommendation for the type or types of glove to use when handling this product is based on information from the following source: EN374. There is no one glove material or combination of materials that will give unlimited resistance to any individual or combination of chemicals. The breakthrough time must be greater than the end use time of the product. The instructions and information provided by the glove manufacturer on use, storage, maintenance and replacement must be followed. Gloves should be replaced regularly and if there is any sign of damage to the glove material. Always ensure that gloves are free from defects and that they are stored and used correctly. The performance or effectiveness of the glove may be reduced by physical/chemical damage and poor maintenance. Barrier creams may help to protect the exposed areas of the skin but should not be applied once exposure has occurred.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. Use eye protection according to EN 166. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: organic vapour filter (Type A) particulate filter (EN 140)

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Recommended: Personnel should wear antistatic clothing made of natural fibres or of high-temperature-resistant synthetic fibres. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Relative Density
---
Boiling Point
Not available.
Solubility In Water
Not available.
Auto Ignition Temperature
350°C (662°F)
Dynamic Viscosity
Not available.
Properties Status
---
Form
Spray
Physical State
Liquid. [Aerosol.]
Flash Point
Closed cup: -40°C (-40°F) [Literature]
Cloud Point
---
Upper Explosive Limit
18%
Relative Evaporation Rate
---
Bulk Density
---
Lower Explosive Limit
3%
Freezing Point
---
Decomposition Temperature
---
Odor Threshold
Not available.
Solidification Point
---
Appearance
---
Flammability
---
Ph
Not applicable.
Crystallisation Point
---
Odor
Solvent-like [Slight]
Vapor Pressure
400 kPa (3000 mm Hg) [calculated.]
Physical State Data
aerosol
Colour Intensity
---
Density
0,78 to 0,86 g/cm³ [20°C (68°F)] [DIN 53217]
Evaporation Rate
---
Kinematic Viscosity
Not available.
Partition Coefficient
Not applicable.
Melting Point
Not available.
Metal Corrosion
---
Vapor Density
---
Colour
Various
Voc Content
---
Molecular Weight
---
Softening Point
---
State Under Standard Conditions
---
Solubility In Fat
---
Solubility
cold water: Not soluble, hot water: Not soluble
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame).

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS, flammable
IMDG

63, 190, 277, 327, 344, 381, 959

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 2700 Hard Hat Advanced Primer and Topcoat?

The signal word is danger.

What is the physical form of 2700 Hard Hat Advanced Primer and Topcoat?

2700 Hard Hat Advanced Primer and Topcoat is a liquid. [aerosol.] with various color. It has solvent-like [slight] odor.

What is the solubility of 2700 Hard Hat Advanced Primer and Topcoat?

cold water: Not soluble, hot water: Not soluble

What is 2700 Hard Hat Advanced Primer and Topcoat used for?

Consumer Industrial Professional

What are the hazard statements for 2700 Hard Hat Advanced Primer and Topcoat?

This substance has 2 hazard statements:

  • H222: Extremely flammable aerosol. Pressurised container: may burst if heated.
  • H336: May cause drowsiness or dizziness.

What is the melting point of 2700 Hard Hat Advanced Primer and Topcoat?

The melting point is Not available. and the boiling point is Not available..