01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
2100 Hard-Hat® Series Finishes
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A
UFI Code
VS00-P0RM-500U-SCAE

Identified Uses

Consumer use, Industrial use, Professional use

Uses advised against

None identified.

Manufacturers & Suppliers

M

Martin Mathys NV

manufacturer

Kolenbergstraat 23, B-3545 Zelem, Belgium

+32 (0) 13 460 200

T

Tor Coatings Limited

distributor

Unit 21, White Rose Way, Follingsby Park, Gateshead, Tyne & Wear, NE10 8YX United Kingdom

+44 (0) 191 4106611

Emergency Contacts

Emergency Contact

+44 870 8200418

24 / 7

Emergency Contact

+44 2038073798

24 / 7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H335
STOT RE Cat. 2 H373

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H222 Extremely flammable aerosol. Pressurised container: may burst if heated.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P103 Read carefully and follow all instructions.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P260 Do not breathe vapour or spray.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves. Wear eye or face protection.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
dimethyl ether EC: 204-065-8 115-10-6 50 - 75% Yes
Reaction mass of ethylbenzene and xylene --- 10 - 25% Yes
xylene (mixture of isomeres) EC: 215-535-7 1330-20-7 10% Yes
ethylbenzene EC: 202-849-4 100-41-4 3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Adverse symptoms may include the following: respiratory tract irritation, coughing

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Adverse symptoms may include the following: irritation, redness

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: Adverse symptoms may include the following: pain or irritation, watering, redness

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention following exposure or if feeling unwell. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

Extremely flammable aerosol. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion. Bursting aerosol containers may be propelled from a fire at high speed.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. In the case of aerosols being ruptured, care should be taken due to the rapid escape of the pressurised contents and propellant. If a large number of containers are ruptured, treat as a bulk material spillage according to the instructions in the clean-up section. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

If a large number of containers are ruptured, treat as a bulk material spillage according to the instructions in the clean-up section.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C. Do not pierce or burn, even after use. Do not breathe vapour or mist. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous.

Storage

Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapour or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. > 8 hours (breakthrough time): polyethylene (PE), polyvinyl alcohol (PVA), Viton® (0.65mm). The recommendation for the type or types of glove to use when handling this product is based on information from the following source: EN374.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. Use eye protection according to EN 166. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: organic vapour (Type AX) and particulate filter (EN 140).

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Recommended: Personnel should wear antistatic clothing made of natural fibres or of high-temperature-resistant synthetic fibres. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid. [Aerosol.]
Solidification Point
---
Properties Status
---
Ph
Not applicable.
Freezing Point
---
Colour
Various
Melting Point
Not available.
Solubility In Fat
---
Relative Density
---
Lower Explosive Limit
3%
Voc Content
---
Flammability
---
Boiling Point
Not available.
Partition Coefficient
---
Dynamic Viscosity
---
Form
Spray
Molecular Weight
---
Colour Intensity
---
Odor
Hydrocarbon.
Density
0,88 to 0,98 g/cm³ [20°C (68°F)] [DIN 53217]
Evaporation Rate
---
Solubility
---
Upper Explosive Limit
18%
Explosive Limits
---
Bulk Density
---
Decomposition Temperature
---
Relative Evaporation Rate
---
Vapor Density
>1 [Air = 1]
Vapor Pressure
420 kPa (3150,26 mm Hg) [calculated.]
Auto Ignition Temperature
350°C (662°F) [Literature]
Crystallisation Point
---
Flash Point
Closed cup: -40°C (-40°F) [Literature]
Softening Point
---
Kinematic Viscosity
---
Solubility In Water
---
Metal Corrosion
---
Appearance
---
Odor Threshold
Not available.
Cloud Point
---
State Under Standard Conditions
---
Physical State Data
aerosol
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame).

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS, flammable
IMDG

≤ 1L: Limited Quantity - IMDG 3.4

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 2100 Hard-Hat® Series Finishes?

The signal word is danger.

What is the physical form of 2100 Hard-Hat® Series Finishes?

2100 Hard-Hat® Series Finishes is a liquid. [aerosol.] with various color. It has hydrocarbon. odor.

What is 2100 Hard-Hat® Series Finishes used for?

Consumer use, Industrial use, Professional use

What are the hazard statements for 2100 Hard-Hat® Series Finishes?

This substance has 5 hazard statements:

  • H222: Extremely flammable aerosol. Pressurised container: may burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of 2100 Hard-Hat® Series Finishes?