NextSDS Logo
Safety Data Sheet EN

G-335 INDUSTRIAL X-RAY FIXER PART A

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
G-335 INDUSTRIAL X-RAY FIXER PART A
Product Code
LXW6T, LXW7V, LXW8X, 38WRN

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Photographic fixing concentrate

Manufacturers & Suppliers

A

Agfa Corporation

manufacturer

100 Challenger Road, Ridgefield Park, NJ 07660, U.S.A.

+1 201 4402500

Emergency Contacts

CHEMTREC

+1 800 4249300

CHEMTREC

+1 703 5273887

Emergency Contact

+1 303 6235716

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous photographic fixing concentrate, mainly consisting of:

Chemical Name CAS Number Concentration Hazardous
Ammonium thiosulphate 7783-18-8 40 - 60% No
Sodium sulphite 7757-83-7 1 - 5% No
Acetic acid 64-19-7 1 - 5% No
Boric acid 10043-35-3 1 - 5% No
Water 7732-18-5 30 - 40% No
Sodium acetate 127-09-3 1 - 5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Take person to fresh air. If necessary, seek medical advice.

Skin contact

Wash immediately with plenty of water and soap. If symptoms persist, seek medical advice.

Eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

Ingestion

Rinse mouth with plenty of water. Seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All extinguishing media are suitable.

Specific hazards

In case of fire, thermal decomposition with emission of hazardous fumes is possible (e.g. sulphur dioxide and ammonia).

Firefighter Protection

Firefighters should be equipped with self-contained breathing apparatus to protect against potentially toxic and irritating fumes.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Large spill

Collect large spills into a properly labelled and sealable container.

Environmental

For waste disposal see section 13.

Cleanup methods

Soak up with absorbent material. Collect large spills into a properly labelled and sealable container.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Keep container tightly closed. Protect from direct sunlight.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Upper Explosive Limit
---
Vapor Pressure
---
Physical State
Liquid.
Ph
5.4
Dynamic Viscosity
---
Freezing Point
---
Physical State Data
liquid
Cloud Point
---
Solubility
---
Voc Content
3.0 % VOC content excluding water
Relative Density
1.343 at 20 °C (68 °F)
Solubility In Water
---
Appearance
---
Flash Point
---
Colour
Colourless.
Density
---
Form
---
Softening Point
---
Metal Corrosion
---
Odor Threshold
---
Partition Coefficient
---
Solidification Point
---
Flammability
---
Bulk Density
---
Properties Status
---
Molecular Weight
---
Explosive Limits
---
Boiling Point
> 100 °C (> 212 °F)
Colour Intensity
---
Melting Point
< 0 °C (< 32 °F)
Crystallisation Point
---
Lower Explosive Limit
---
Odor
Slightly pungent smell
Decomposition Temperature
---
Auto Ignition Temperature
---
Solubility In Fat
---
Kinematic Viscosity
---
Evaporation Rate
---
Vapor Density
---
State Under Standard Conditions
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under normal conditions of storage and use.

Avoid

Remove all chemicals and rinse the processing tanks thoroughly with water before using any cleansing products.

Incompatible

strong acids, strong alkalis and strong oxidizing agents

Decomposition

Sulphur dioxide and ammonia

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for G-335 INDUSTRIAL X-RAY FIXER PART A?

The signal word is no signal word.

What is the physical form of G-335 INDUSTRIAL X-RAY FIXER PART A?

G-335 INDUSTRIAL X-RAY FIXER PART A is a liquid. with colourless. color. It has slightly pungent smell odor.

What is G-335 INDUSTRIAL X-RAY FIXER PART A used for?

Photographic fixing concentrate

What is the melting point of G-335 INDUSTRIAL X-RAY FIXER PART A?

The melting point is < 0 °C (< 32 °F) and the boiling point is > 100 °C (> 212 °F).