Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HyVolt I
- Synonyms
- HyVolt I BS 148
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Transformer Oil
Uses advised against
None known.
Manufacturers & Suppliers
Ergon Refining, Inc.
manufacturer
2611 Haining Road Vicksburg, Mississippi 39183
Emergency Contacts
Ergon Refining
1.601.638.4960
Normal Business Hours
Chemtrec
1.800.424.9300
Chemtrec
1.703.527.3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| DISTILLATES (PETROLEUM), HYDROTREATED LIGHT NAPHTHENIC | 64742-53-6 | 20 - 100% | No |
| DISTILLATES (PETROLEUM), HYDROTREATED LIGHT PARAFFINIC | 64742-55-8 | 40% | No |
| LUBRICATING OILS (PETROLEUM), C15-30, HYDROTREATED NEUTRAL OIL-BASED | 72623-86-0 | 40% | No |
| LUBRICATING OILS (PETROLEUM), C20-50, HYDROTREATED NEUTRAL OIL-BASED | 72623-87-1 | 20% | No |
| DISTILLATES (PETROLEUM), SOLVENT-REFINED HEAVY NAPHTHENIC | 64741-96-4 | 10% | No |
| DISTILLATES (PETROLEUM), SOLVENT-REFINED LIGHT PARAFFINIC | 64741-89-5 | 10% | No |
Material name: HyVolt I
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Oxygen or artificial respiration if needed. Do not use mouth-to-mouth method if victim inhaled the substance. Induce artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device.
Symptoms: Coughing, discomfort in the chest.
Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse.
Symptoms: Defatting of the skin, allergic skin reaction.
Flush thoroughly with water.
Symptoms: Irritation.
Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Call a poison control center immediately.
Immediate Medical Attention
IF exposed or concerned: Get medical advice/attention. If skin irritation or an allergic skin reaction develops, get medical attention. If irritation occurs, get medical assistance. Call a poison control center immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Halon, Dry chemicals, Foam, Carbon dioxide (CO2), Water spray or fog.
Do not use a solid water stream as it may scatter and spread fire. Do not use water jet as an extinguisher, as this will spread the fire.
No unusual fire or explosion hazards noted.
Cool containers exposed to flames with water until well after the fire is out.
Firefighter Protection
Wear full protective clothing, including helmet, self-contained positive pressure or pressure demand breathing apparatus, protective clothing and face mask. Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA. Use pressurized air mask if product is involved in a fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unnecessary personnel away. Wear appropriate protective equipment and clothing during clean-up. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Ensure adequate ventilation.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Cover with plastic sheet to prevent spreading. Absorb in vermiculite, dry sand or earth or absorbent material then place into containers. Following product recovery, flush area with water.
Prevent further leakage or spillage if safe to do so. Prevent entry into waterways, sewer, basements or confined areas. Avoid discharge to the aquatic environment. Contact local authorities in case of spillage to drain/aquatic environment.
Absorb in vermiculite, dry sand or earth or absorbent material then place into containers. Following product recovery, flush area with water. Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Materials: vermiculite, dry sand, earth, absorbent material, cloth, fleece
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
DO NOT handle, store or open near an open flame, sources of heat or sources of ignition. Protect material from direct sunlight. Do not breathe dust/fume/gas/mist/vapors/spray. Wash hands after handling and before eating. Do not get this material in contact with eyes. Avoid contact with skin. Avoid prolonged exposure. All handling to take place in well-ventilated area. Shower after work. Remove and wash contaminated clothing promptly.
Store locked up. Keep away from heat, sparks and open flame. Store in a well-ventilated place. Use care in handling/storage. Protect material from direct sunlight.
Wash hands after handling and before eating. Shower after work. Remove and wash contaminated clothing promptly.
DO NOT handle, store or open near an open flame, sources of heat or sources of ignition. Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable.
The product is stable and non-reactive under normal conditions of use, storage and transport.
Hazardous polymerization does not occur.
Heat, flames and sparks. Avoid temperatures exceeding the flash point.
Strong oxidizing agents.
Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
Not expected to be harmful to aquatic organisms.
Persistence and degradability
Not inherently biodegradable.
Bioaccumulative potential
Bioaccumulation is unlikely to be significant because of the low water solubility of this product.
Mobility in soil
Results of PBT and vPvB assessment
Endocrine disrupting properties
Other adverse effects
No other adverse environmental effects are expected.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations.
Disposal recommendations are based on material as supplied. Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product is a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200.
HyVolt oils are certified to be PCB-free. HyVolt oils are processed from naturally occurring raw materials with no additives or recycled oils that might introduce PCB contamination.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is HyVolt I known by?
HyVolt I is also known as: HyVolt I BS 148
What is the hazard signal word for HyVolt I?
The signal word is danger.
What is the physical form of HyVolt I?
HyVolt I is a liquid. appearing as clear & bright with water white to pale color. It has mild petroleum odor odor.
What is HyVolt I used for?
Transformer Oil
What is the melting point of HyVolt I?
The melting point is -77.8 °F (-61 °C) ASTM D5950/ISO 3016 and the boiling point is 564.8 °F (296 °C) ISO 3294/ ASTM D2887.