Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
HyVolt NG is a clear & bright substance commonly used transformer oil.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS08
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H304: May be fatal if swallowed and enters airways.
Precautionary Statements
- P260: Do not breathe gas/mist/vapours/spray.
- P331: Do NOT induce vomiting.
- P405: Store locked up.
- P501: Dispose of contents/container in accordance with local/regional/national/international regulations
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Ergon, Inc.
manufacturer
P.O. Box 1639 Jackson, MS 39181 USA
US
Ergon International, Inc.
regional supplier
Drve Richelle 161 Building C B-1410 Waterloo, Belgium
BE
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
US Customer Service
+ 1-800-222-7122
US
Chemtrec
+ 1-800-424-9300
US
After Business Hours
North America
Chemtrec
+ 1-703-527.-3887
US
International
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated light naphthenic EC: 265-156-6 | 64742-53-6 | 50-100% | โ ๏ธ Hazardous |
| Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 | 64742-55-8 | 50% | โ ๏ธ Hazardous |
| Lubricating Oils (petroleum), C15-30, Hydrotreated Neutral Oil-based EC: 276-737-9 | 72623-86-0 | 50% | โ ๏ธ Hazardous |
| DISTILLATES (PETROLEUM), SOLVENT-REFINED HEAVY NAPHTHENIC EC: 265-097-6 | 64741-96-4 | 10% | โ ๏ธ Hazardous |
| DISTILLATES (PETROLEUM), SOLVENT-REFINED LIGHT PARAFFINIC EC: 265-091-3 | 64741-89-5 | 10% | โ ๏ธ Hazardous |
| Solvent naphtha (petroleum), heavy arom. EC: 265-198-5 | 64742-94-5 | 5% | โ ๏ธ Hazardous |
Composition Notes
Note L - Not classified as a carcinogen. Meets EU requirement of less than 3% (w/w) DMSO extract for total polycyclic aromatic compound (PAC) using IP 346.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air. Oxygen or artificial respiration if needed. IF exposed or concerned: Get medical advice/attention.
๐๏ธ Skin Contact
Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If skin irritation or an allergic skin reaction develops, get medical attention.
Symptoms:
Skin irritation or an allergic skin reaction develops, Defatting of the skin.
๐๏ธ Eye Contact
Flush thoroughly with water. If irritation occurs, get medical assistance.
Symptoms:
Irritation
๐ฝ๏ธ Ingestion/Swallowing
Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Call a poison control centre immediately.
๐จ Immediate Medical Attention Required
Treat symptomatically.
Medical Treatment
Treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.
๐งค Hand Protection
Chemical resistant gloves are recommended. If contact with forearms is likely wear gauntlet style gloves. When prolonged or frequent repeated contact occurs, Nitrile gloves may be suitable. (Breakthrough time of > 240 minutes.) For incidental contact/splash protection Neoprene, PVC gloves may be suitable.
๐๏ธ Eye Protection
Goggles/face shield are recommended.
๐ท Respiratory Protection
No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [boiling point >65 C (149 F)] meeting EN14387.
๐ฆบ Skin/Body Protection
Chemical/oil resistant clothing is recommended. Launder contaminated clothing before reuse.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for HyVolt NG?
The signal word for this substance is "danger".
What is the physical form of HyVolt NG?
HyVolt NG is a liquid. appearing as clear & bright with water white color. It has mild petroleum odor odor.
What is the solubility of HyVolt NG?
Not available.
What is HyVolt NG used for?
Transformer Oil
What are the hazard statements for HyVolt NG?
This substance has 1 hazard statements: H304: May be fatal if swallowed and enters airways.
What is the melting point of HyVolt NG?
The melting point is <= -20 C (<= -4 F) ASTM D5950 and the boiling point is >= 232 C (>= 449,6 F).