NextSDS Logo
Hy

HyVolt NG

DANGER Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
HyVolt NG

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Transformer Oil
Uses Advised Against
None known.

Overview

HyVolt NG is a clear & bright substance commonly used transformer oil.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Asp. Tox. Category 1 H304

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H304: May be fatal if swallowed and enters airways.

Precautionary Statements

  • P260: Do not breathe gas/mist/vapours/spray.
  • P331: Do NOT induce vomiting.
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Ergon, Inc.

manufacturer

๐Ÿ“

P.O. Box 1639 Jackson, MS 39181 USA

๐ŸŒ

US

Ergon International, Inc.

regional supplier

๐Ÿ“

Drve Richelle 161 Building C B-1410 Waterloo, Belgium

๐ŸŒ

BE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

US Customer Service

๐Ÿ“ž

+ 1-800-222-7122

๐ŸŒ

US

Chemtrec

๐Ÿ“ž

+ 1-800-424-9300

๐ŸŒ

US

๐Ÿ•’

After Business Hours

๐Ÿ’ก

North America

Chemtrec

๐Ÿ“ž

+ 1-703-527.-3887

๐ŸŒ

US

๐Ÿ’ก

International

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated light naphthenic
EC: 265-156-6
64742-53-6 50-100% โš ๏ธ Hazardous
Distillates (petroleum), hydrotreated light paraffinic
EC: 265-158-7
64742-55-8 50% โš ๏ธ Hazardous
Lubricating Oils (petroleum), C15-30, Hydrotreated Neutral Oil-based
EC: 276-737-9
72623-86-0 50% โš ๏ธ Hazardous
DISTILLATES (PETROLEUM), SOLVENT-REFINED HEAVY NAPHTHENIC
EC: 265-097-6
64741-96-4 10% โš ๏ธ Hazardous
DISTILLATES (PETROLEUM), SOLVENT-REFINED LIGHT PARAFFINIC
EC: 265-091-3
64741-89-5 10% โš ๏ธ Hazardous
Solvent naphtha (petroleum), heavy arom.
EC: 265-198-5
64742-94-5 5% โš ๏ธ Hazardous

Composition Notes

Note L - Not classified as a carcinogen. Meets EU requirement of less than 3% (w/w) DMSO extract for total polycyclic aromatic compound (PAC) using IP 346.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air. Oxygen or artificial respiration if needed. IF exposed or concerned: Get medical advice/attention.

๐Ÿ–๏ธ Skin Contact

Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If skin irritation or an allergic skin reaction develops, get medical attention.

Symptoms:

Skin irritation or an allergic skin reaction develops, Defatting of the skin.

๐Ÿ‘๏ธ Eye Contact

Flush thoroughly with water. If irritation occurs, get medical assistance.

Symptoms:

Irritation

๐Ÿฝ๏ธ Ingestion/Swallowing

Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Call a poison control centre immediately.

๐Ÿšจ Immediate Medical Attention Required

Treat symptomatically.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Clear & bright
๐ŸŽจ Colour
Water White
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid.
๐Ÿ‘ƒ Odor
Mild Petroleum Odor
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
<= -20 C (<= -4 F) ASTM D5950
Critical Property
๐Ÿ’จ Boiling Point
>= 232 C (>= 449,6 F)
Critical Property
๐Ÿ”ฅ Flash Point
>= 140,0 C (>= 284,0 F) Pensky-Martens Closed Cup ASTM D93
Critical Property
๐Ÿ“Š Freezing Point
<= -20 C (<= -4 F) ASTM D5950
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
0,88 ASTM D1298
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
5 % estimated
๐Ÿ“Š Lower Explosive Limit
0,7 % estimated
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
>= 315 C (>= 599 F)
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Not available.
๐Ÿ“Š Partition Coefficient
Not established.
๐Ÿ“Š Solubility In Water
Not available.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
<= 11 mm/s (40 C (104 F) ASTM D445)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.

๐Ÿงค Hand Protection

Chemical resistant gloves are recommended. If contact with forearms is likely wear gauntlet style gloves. When prolonged or frequent repeated contact occurs, Nitrile gloves may be suitable. (Breakthrough time of > 240 minutes.) For incidental contact/splash protection Neoprene, PVC gloves may be suitable.

๐Ÿ‘๏ธ Eye Protection

Goggles/face shield are recommended.

๐Ÿ˜ท Respiratory Protection

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [boiling point >65 C (149 F)] meeting EN14387.

๐Ÿฆบ Skin/Body Protection

Chemical/oil resistant clothing is recommended. Launder contaminated clothing before reuse.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for HyVolt NG?

The signal word for this substance is "danger".

What is the physical form of HyVolt NG?

HyVolt NG is a liquid. appearing as clear & bright with water white color. It has mild petroleum odor odor.

What is the solubility of HyVolt NG?

Not available.

What is HyVolt NG used for?

Transformer Oil

What are the hazard statements for HyVolt NG?

This substance has 1 hazard statements: H304: May be fatal if swallowed and enters airways.

What is the melting point of HyVolt NG?

The melting point is <= -20 C (<= -4 F) ASTM D5950 and the boiling point is >= 232 C (>= 449,6 F).