Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- NEONATAL TSH Screening ELISA
- Product Code
- E-GP-192C-576C-1920C
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For in vitro diagnostic use only
Manufacturers & Suppliers
LaCAR MDx technologies
manufacturer
Liège Science Park, Rue des Chasseurs Ardennais,10, 4031 Liège, Belgium
+32 (0) 4 287 39 44
Emergency Contacts
Emergency Contact
+1 703 527 3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Calibrators [CAL] Control [CONTROL] | --- | --- | No |
| Microtiter plate [SORB MTP] | --- | --- | No |
| ProClin™ 300 EC: 911-418-6 | 55965-84-9 | 0.0015 - 0.06% | Yes |
| gentamicin sulfate EC: 215-778-9 | 1405-41-0 | 100% | Yes |
| Chromogenic Substrate [SUBS TMB] | --- | --- | No |
| sulfuric acid EC: 231-639-5 | 7667-93-9 | 5% | Yes |
| merthiolate EC: 207-838-8 | 497-19-8 | 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. After inhalation: fresh air. Call a physician.
Wash off with soap and plenty of water. Consult a physician. Take off immediately all contaminated clothing. Rinse skin with water / shower. Call a physician immediately.
Flush eyes with water as a precaution. Rinse out with plenty of water. Immediately call an ophthalmologist. Remove contact lenses.
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. If swallowed: give water to drink (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise.
Immediate Medical Attention
Consult a physician. Call a physician immediately. Immediately call an ophthalmologist.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance no limitations of extinguishing agents are given.
Gentamicin Sulfate: Combustible. Development of hazardous combustion gases or vapours possible in the event of fire. ProClin™ 300: Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts (Gentamicin Sulfate). Do not breathe vapors, aerosols (ProClin™ 300). Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up carefully. Dispose of properly. Clean up affected area.
Materials: liquid-absorbent and neutralising material (e.g. Chemizorb® H⁺, Merck Art. No. 101595)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Gentamicin Sulfate: Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons. Recommended storage condition: 2-8°C. ProClin™ 300: Tightly closed.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gentamicin Sulfate: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. ProClin™ 300 (Full contact): Material: butyl-rubber, Minimum layer thickness: 0,3 mm, Break through time: 480 min, Material tested: Butoject® (KCL 897 / Aldrich Z677647, Size M). ProClin™ 300 (Splash contact): Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 60 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M).
Gentamicin Sulfate: Safety glasses. ProClin™ 300: Tightly fitting safety goggles. Both: Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Gentamicin Sulfate: Required when dusts are generated. Recommended Filter type: Filter type P2. ProClin™ 300: Required when vapours/aerosols are generated. Recommended Filter type: Filter type ABEK. Both: Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Protective clothing.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
the product is chemically stable under standard ambient conditions (room temperature).
Gentamicin Sulfate: The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed. ProClin™ 300: Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
For ProClin™ 300: no data available. For gentamicin sulfate: violent reactions possible with strong oxidizing agents.
Gentamicin Sulfate: No information available; ProClin™ 300: Strong heating
Gentamicin Sulfate: No information available; ProClin™ 300: Strong oxidizing agents, Reducing agents, Amines, Mercaptans
In the event of fire: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
The substance/mixture does not contain PBT or vPvB components at concentrations of 0.1% or higher.
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3265
- Shipping Name
- CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S. (Mixture of 5-Chloro-2-methyl-4-isothiazolin-3-one and 2-Methyl-2H -isothiazol-3-one (3:1))
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This safety datasheet complies with the requirement of Regulation (EC) No 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for NEONATAL TSH Screening ELISA?
The signal word is danger.
What is the physical form of NEONATAL TSH Screening ELISA?
NEONATAL TSH Screening ELISA is a liquid appearing as data no available with data no available color. It has no data available odor.
What is NEONATAL TSH Screening ELISA used for?
For in vitro diagnostic use only
What are the hazard statements for NEONATAL TSH Screening ELISA?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
What is the melting point of NEONATAL TSH Screening ELISA?
The melting point is -40°C and the boiling point is 189°C.