Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Aersopray® Gram Reagent B, Iodine
- Product Form
- Mixture
- Product Code
- SS-041B, SS-041B-EU, SS-141B
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Gram staining Laboratory chemical
Uses advised against
No additional information available
Manufacturers & Suppliers
ELITechGroup Inc.
manufacturer
370 West 1700 South, US–84321 Logan, UT – Cache, USA
+1 (435) 752-6011
http://www.elitechgroup.com
Emergency Contacts
InfoTrac Emergency Response
1-800-535-5053
InfoTrac Emergency Response
+1 352-323-3500
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH Annex II
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. Allow affected person to breathe fresh air. Allow the victim to rest.
Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. Wash skin with plenty of water.
Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists. Rinse eyes with water as a precaution.
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention. Call a poison center or a doctor if you feel unwell.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Dry powder. Carbon dioxide. Water spray. Sand.
Do not use a heavy water stream.
Toxic fumes may be released.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection. Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ventilate spillage area. Evacuate unnecessary personnel.
Avoid release to the environment.
Take up liquid spill into absorbent material. Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage. Store away from other materials.
Materials: inert solids, such as clay or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Aerospray® Gram Reagent C, Crystal Violet
---
Aerospray® Gram Reagent A, Decolorizer with Acetone and Fuchsin
---
Grams Iodine
---
Aerospray® TB Reagent C, Auramine O
---
Iodine sublimated for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7553-56-2
Aerospray® Hematology Pro Reagent B, Thiazin Stain
---
Lugol's Iodine
---
Aerospray® TB Reagent A, Fluorescence Decolorizer
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation of the work station. Wear personal protective equipment. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour.
Keep cool. Protect from sunlight. Store in a well-ventilated place. Keep cool.
Do not eat, drink or smoke when using this product. Always wash hands after handling the product. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation of the work station.
Wear protective gloves. Suitable gloves should be tested to EN 374. The glove material has to be impermeable and resistant to the product/the substance/the preparation. As the product is a preparation of several substances, the resistance and penetration time/breakthrough time of the glove material cannot be calculated/observed in advance and, therefore, has to be checked prior to the application. The following are recommended: materials - natural latex or nitrile; thickness - 4 to 6 mils (0.1 mm - 0.15 mm); minimum breakthrough time - 60 minutes.
Chemical goggles or safety glasses. Safety glasses
Wear appropriate mask
Wear suitable protective clothing
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Not established.
The product is non-reactive under normal conditions of use, storage and transport.
Not established.
Direct sunlight. Extremely high or low temperatures.
Strong acids. Strong bases.
fume. Carbon monoxide. Carbon dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
The product is not considered harmful to aquatic organisms nor to cause long-term adverse effects in the environment.
12.2. Persistence and degradability
Not established.
12.3. Bioaccumulative potential
Not established.
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Endocrine disrupting properties
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of contents/container in accordance with licensed collector's sorting instructions.
Dispose in a safe manner in accordance with local/national regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Aersopray® Gram Reagent B, Iodine?
The signal word is no signal word.
What is the physical form of Aersopray® Gram Reagent B, Iodine?
Aersopray® Gram Reagent B, Iodine is a liquid with brown color. It has characteristic odour odor.
What is the solubility of Aersopray® Gram Reagent B, Iodine?
Water: No data available
What is Aersopray® Gram Reagent B, Iodine used for?
Gram staining Laboratory chemical
What is the melting point of Aersopray® Gram Reagent B, Iodine?
The melting point is Not applicable and the boiling point is 98.3 °C.